These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 27481856)

  • 21. A comprehensive factorial design study of variables affecting protein extraction from formalin-fixed kidney tissue samples.
    Araújo JE; Oliveira E; Otero-Glez A; Santos Nores J; Igrejas G; Lodeiro C; Capelo JL; Santos HM
    Talanta; 2014 Feb; 119():90-7. PubMed ID: 24401389
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An efficient organic solvent based extraction method for the proteomic analysis of Arabidopsis plasma membranes.
    Mitra SK; Walters BT; Clouse SD; Goshe MB
    J Proteome Res; 2009 Jun; 8(6):2752-67. PubMed ID: 19334764
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging.
    Lankes U; Elder PA; Lewis JG; George P
    Ann Clin Biochem; 2015 Jan; 52(Pt 1):151-60. PubMed ID: 24714680
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A simple method for sphingolipid analysis of tissues embedded in optimal cutting temperature compound.
    Rohrbach TD; Boyd AE; Grizzard PJ; Spiegel S; Allegood J; Lima S
    J Lipid Res; 2020 Jun; 61(6):953-967. PubMed ID: 32341007
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Development of a Robust Ultrasonic-Based Sample Treatment To Unravel the Proteome of OCT-Embedded Solid Tumor Biopsies.
    Jorge S; Capelo JL; LaFramboise W; Dhir R; Lodeiro C; Santos HM
    J Proteome Res; 2019 Jul; 18(7):2979-2986. PubMed ID: 31173681
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of liquid chromatography-tandem mass spectrometry-based targeted proteomics and conventional analytical methods for the determination of P-glycoprotein in human breast cancer cells.
    Yang T; Xu F; Xu J; Fang D; Yu Y; Chen Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Oct; 936():18-24. PubMed ID: 23968647
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)-Based Proteomics of Drug-Metabolizing Enzymes and Transporters.
    Li J; Zhu HJ
    Molecules; 2020 Jun; 25(11):. PubMed ID: 32545386
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Histology-guided protein digestion/extraction from formalin-fixed and paraffin-embedded pressure ulcer biopsies.
    Taverna D; Pollins AC; Nanney LB; Sindona G; Caprioli RM
    Exp Dermatol; 2016 Feb; 25(2):143-6. PubMed ID: 26440596
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An off-line high pH reversed-phase fractionation and nano-liquid chromatography-mass spectrometry method for global proteomic profiling of cell lines.
    Wang H; Sun S; Zhang Y; Chen S; Liu P; Liu B
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Jan; 974():90-5. PubMed ID: 25463202
    [TBL] [Abstract][Full Text] [Related]  

  • 30. LC-MS/MS-based targeted proteomics quantitatively detects the interaction between p53 and MDM2 in breast cancer.
    Zhang W; Zhong T; Chen Y
    J Proteomics; 2017 Jan; 152():172-180. PubMed ID: 27826076
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Absolute protein quantification of clinically relevant cytochrome P450 enzymes and UDP-glucuronosyltransferases by mass spectrometry-based targeted proteomics.
    Gröer C; Busch D; Patrzyk M; Beyer K; Busemann A; Heidecke CD; Drozdzik M; Siegmund W; Oswald S
    J Pharm Biomed Anal; 2014 Nov; 100():393-401. PubMed ID: 25218440
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Extraction of proteins from formalin-fixed, paraffin-embedded tissue using the Qproteome extraction technique and preparation of tryptic peptides for liquid chromatography/mass spectrometry analysis.
    Geoui T; Urlaub H; Plessmann U; Porschewski P
    Curr Protoc Mol Biol; 2010 Apr; Chapter 10():Unit 10.27.1-12. PubMed ID: 20373500
    [TBL] [Abstract][Full Text] [Related]  

  • 33. i-RUBY: a novel software for quantitative analysis of highly accurate shotgun-proteomics liquid chromatography/tandem mass spectrometry data obtained without stable-isotope labeling of proteins.
    Wada K; Ogiwara A; Nagasaka K; Tanaka N; Komatsu Y
    Rapid Commun Mass Spectrom; 2011 Apr; 25(7):960-8. PubMed ID: 21416533
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Mass spectrometric quantification of urinary human liver fatty acid binding protein in renal transplant recipients.
    Ozcan F; Akbas H; Kırac E; Suleymanlar G; Aslan M; Yucel G
    Rapid Commun Mass Spectrom; 2016 Mar; 30(5):603-10. PubMed ID: 27043149
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Development of a highly sensitive liquid chromatography/tandem mass spectrometry method to quantify total and free levels of a target protein, interferon-gamma-inducible protein-10, at picomolar levels in human serum.
    Zhang H; Xiao Q; Xin B; Trigona W; Tymiak AA; Dongre AR; Olah TV
    Rapid Commun Mass Spectrom; 2014 Jul; 28(13):1535-43. PubMed ID: 24861605
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Validation of an LC-MS/MS method to measure tacrolimus in rat kidney and liver tissue and its application to human kidney biopsies.
    Noll BD; Coller JK; Somogyi AA; Morris RG; Russ GR; Hesselink DA; Van Gelder T; Sallustio BC
    Ther Drug Monit; 2013 Oct; 35(5):617-23. PubMed ID: 23921430
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Confirmatory and quantitative analysis of beta-lactam antibiotics in bovine kidney tissue by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry.
    Fagerquist CK; Lightfield AR; Lehotay SJ
    Anal Chem; 2005 Mar; 77(5):1473-82. PubMed ID: 15732933
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Tagless extraction-retentate chromatography: a new global protein digestion strategy for monitoring differential protein expression.
    Weinberger SR; Viner RI; Ho P
    Electrophoresis; 2002 Sep; 23(18):3182-92. PubMed ID: 12298090
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Isotope coded protein label quantification of serum proteins--comparison with the label-free LC-MS and validation using the MRM approach.
    Turtoi A; Mazzucchelli GD; De Pauw E
    Talanta; 2010 Feb; 80(4):1487-95. PubMed ID: 20082806
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of Different Buffers for Protein Extraction from Formalin-Fixed and Paraffin-Embedded Tissue Specimens.
    Shen K; Sun J; Cao X; Zhou D; Li J
    PLoS One; 2015; 10(11):e0142650. PubMed ID: 26580073
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.