These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 27483272)

  • 1. Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging.
    Li J; Chen X; Wang Y; Li W; Yu D
    Sensors (Basel); 2016 Jul; 16(8):. PubMed ID: 27483272
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Generalized sidelobe canceler beamforming combined with Eigenspace-Wiener postfilter for medical ultrasound imaging.
    Yang J; Chen X; Cai H; Wang Y
    Technol Health Care; 2022; 30(S1):501-512. PubMed ID: 35124624
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging.
    Mohammadzadeh Asl B; Mahloojifar A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Nov; 57(11):2381-90. PubMed ID: 21041127
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Eigenspace-based minimum variance beamformer combined with Wiener postfilter for medical ultrasound imaging.
    Zeng X; Chen C; Wang Y
    Ultrasonics; 2012 Dec; 52(8):996-1004. PubMed ID: 22929478
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Eigenspace-based beamformer using oblique signal subspace projection for ultrasound plane-wave imaging.
    Aliabadi S; Wang Y; Yu J; Zhao J; Guo W; Zhang S
    Biomed Eng Online; 2016 Nov; 15(1):127. PubMed ID: 27881172
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Broadband minimum variance beamforming for ultrasound imaging.
    Holfort IK; Gran F; Jensen JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Feb; 56(2):314-25. PubMed ID: 19251518
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multi-apodization with cross-correlation combined with generalized sidelobe canceller applied to ultrasound imaging.
    Wang P; Shen Y; Chen J; Li Q; Tong L; Li X
    Technol Health Care; 2024; 32(3):1713-1731. PubMed ID: 37840511
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adaptive beamforming applied to medical ultrasound imaging.
    Synnevåg JF; Austeng A; Holm S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Aug; 54(8):1606-13. PubMed ID: 17703664
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enhance contrast in PCA based beamformers using smoothing kernel.
    Aliabadi S; Yu J; Wang Y
    Biomed Mater Eng; 2015; 26 Suppl 1():S1613-21. PubMed ID: 26405926
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improvement of performance of minimum variance beamformer by introducing cross covariance estimate.
    Hasegawa H; Nagaoka R
    J Med Ultrason (2001); 2020 Apr; 47(2):203-210. PubMed ID: 32078070
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Generalized sidelobe canceller beamforming method for ultrasound imaging.
    Wang P; Li N; Luo HW; Zhu YK; Cui SG
    J Acoust Soc Am; 2017 Mar; 141(3):1900. PubMed ID: 28372093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Resolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming.
    Diamantis K; Anderson T; Butler MB; Villagomez-Hoyos CA; Jensen JA; Sboros V
    IEEE Trans Med Imaging; 2019 Jan; 38(1):194-204. PubMed ID: 30059295
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Plane wave imaging combined with eigenspace-based minimum variance beamforming using a ring array in ultrasound computed tomography.
    Jiang X; Xiao Y; Wang Y; Yu J; Zheng H
    Biomed Eng Online; 2019 Jan; 18(1):7. PubMed ID: 30674326
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High Resolution Minimum Variance Beamformer With Low Complexity in Medical Ultrasound Imaging.
    Deylami AM; Asl BM
    Ultrasound Med Biol; 2019 Oct; 45(10):2805-2818. PubMed ID: 31320148
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Adaptive subarray coherence based post-filter using array gain in medical ultrasound imaging.
    Eslami L; Mohammadzadeh Asl B
    Ultrasonics; 2022 Dec; 126():106808. PubMed ID: 35921724
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Contrast enhancement and robustness improvement of adaptive ultrasound imaging using forward-backward minimum variance beamforming.
    Asl BM; Mahloojifar A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Apr; 58(4):858-67. PubMed ID: 21507765
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Synthetic Aperture Ultrasound Imaging through Adaptive Integrated Transmitting-Receiving Beamformer.
    Rostamikhanghahi H; Sakhaei SM
    Ultrason Imaging; 2023 May; 45(3):101-118. PubMed ID: 37009752
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Combined phase screen aberration correction and minimum variance beamforming in medical ultrasound.
    Ziksari MS; Asl BM
    Ultrasonics; 2017 Mar; 75():71-79. PubMed ID: 27939788
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Robust finite impulse response beamforming applied to medical ultrasound.
    Guenther DA; Walker WF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Jun; 56(6):1168-88. PubMed ID: 19574125
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Apodized adaptive beamformer.
    Hasegawa H
    J Med Ultrason (2001); 2017 Apr; 44(2):155-165. PubMed ID: 28084559
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.