  • 1. Hemolytic anemia caused by aortic flap and inversion of felt strip after ascending aorta replacement.
    Sakaguchi M; Takano T
    J Cardiothorac Surg; 2016 Aug; 11(1):117. PubMed ID: 27484121
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Hemolysis after ascending and arch replacement of the aorta; report of a case].
    Hori D; Kawahito K; Tanaka M; Nagano H
    Kyobu Geka; 2007 Nov; 60(12):1103-6. PubMed ID: 18018654
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemolytic anemia caused by kinked graft 6 months after aortic dissection repair.
    Tamura K; Tatsuishi W; Konishi Y; Konno N; Kato Y; Abe T
    J Cardiothorac Surg; 2022 Dec; 17(1):308. PubMed ID: 36517888
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Repeat surgery for hemolysis 6 years after replacement of the ascending aorta for acute aortic dissection.
    Izumi S; Tano K; Horike K; Kaihotsu N
    Jpn J Thorac Cardiovasc Surg; 2003 Sep; 51(9):459-61. PubMed ID: 14529167
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Usefulness of three-dimensional transesophageal echocardiography for diagnosis of hemolytic anemia due to inverted internal felt strip after surgery for aortic dissection.
    Oda T; Yasunaga H; Zaima Y; Arimura A; Imai S; Kanamoto R; Fukuda H; Nakamura E; Tashiro H; Aoyagi S
    J Med Ultrason (2001); 2017 Apr; 44(2):211-214. PubMed ID: 27858229
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A surgical case for hemolytic anemia after ascending and total arch replacement.
    Shingu Y; Aoki H; Ebuoka N; Eya K; Takigami K; Oba J; Chiba K; Fukuhara T
    Ann Thorac Cardiovasc Surg; 2005 Dec; 11(6):416-8. PubMed ID: 16401994
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemolytic anemia case caused by an inverted inner felt after bentall operation.
    Kang H; Choe JW; Cho DY; Sohn DS; Kim SW; Hong J
    J Korean Med Sci; 2013 Dec; 28(12):1827-9. PubMed ID: 24339716
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Haemolytic anaemia resulting from the surgical repair of acute type A aortic dissection.
    Sekine Y; Yamamoto S; Fujikawa T; Oshima S; Ono M; Sasaguri S
    Interact Cardiovasc Thorac Surg; 2014 Feb; 18(2):230-3. PubMed ID: 24203981
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Postoperative early hemolytic anemia due to inverted teflon felt strip after emergency repair for type A dissection.
    Hata M; Yoshitake I; Wakui S; Unosawa S; Hata H; Shiono M
    Thorac Cardiovasc Surg; 2012 Oct; 60(7):482-4. PubMed ID: 21766281
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection.
    Sabzi F; Ghasemi F; Asadmobini A
    Ethiop J Health Sci; 2016 Sep; 26(5):497-502. PubMed ID: 28446857
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical and hemodynamic follow-up of a patient after operation for dissection of an ascending aortic aneurysm secondary to coarctation of the aorta.
    Heper G; Yorukoglu Y; Korkmaz ME
    Int Heart J; 2005 Nov; 46(6):1123-31. PubMed ID: 16394608
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elephant trunk in a small-calibre true lumen for chronic aortic dissection: cause of haemolytic anaemia?
    Araki H; Kitamura T; Horai T; Shibata K; Miyaji K
    Interact Cardiovasc Thorac Surg; 2014 Dec; 19(6):1065-7. PubMed ID: 25228241
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Kinked Graft and Anastomotic Stenosis-Induced Hemolytic Anemia Requiring Reoperation.
    Kitahara H; Yoshitake A; Hachiya T; Okamoto K; Kawaguchi S; Shimizu H
    Ann Vasc Surg; 2016 Jan; 30():308.e1-4. PubMed ID: 26524134
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Graft Kink with Hemolytic Anemia Caused by Enlargement of the Residual False Lumen in the Aortic Root:Report of a Case].
    Matsuoka T; Inui A; Yamabi H; Imanaka K
    Kyobu Geka; 2022 Oct; 75(11):951-954. PubMed ID: 36176256
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemolytic anemia caused by an excessively kinked prosthetic graft after total arch replacement detected by 4-dimensional flow magnetic resonance imaging: A case report.
    Takei Y; Shibasaki I; Suzuki K; Miyazaki S; Hirota S; Ohashi H; Saito S; Fukuda H
    Medicine (Baltimore); 2022 Jul; 101(29):e29617. PubMed ID: 35866824
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Risk of late reoperations in patients with acute type A aortic dissection: impact of a more radical surgical approach.
    Pugliese P; Pessotto R; Santini F; Montalbano G; Luciani GB; Mazzucco A
    Eur J Cardiothorac Surg; 1998 May; 13(5):576-80; discussion 580-1. PubMed ID: 9663542
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Utility of Point-of-Care Transesophageal Echocardiography in the Intensive Care Unit for Detecting the Cause of Hemolytic Anemia After Ascending Aorta Replacement.
    Oshima Y; Seino Y; Takagi S; Yamamoto M; Kiuchi N; Nomura T; Suzuki T
    J Cardiothorac Vasc Anesth; 2020 Oct; ():. PubMed ID: 34756354
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A repair of the aortic pseudoaneurysm after ascending aortic grafting in acute type A dissection--a case report].
    Fukuda I; Ohuchi H; Matsuzaki K
    Nihon Kyobu Geka Gakkai Zasshi; 1995 Apr; 43(4):502-5. PubMed ID: 7608601
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemolytic Anemia Caused by Graft Kinking Following Ascending Aortic Replacement: Endovascular Treatment With a Palmaz XL Stent.
    Kato H; Kato N; Ouchi T; Higashigawa T; Bessho S; Shomura Y; Ichikawa Y; Sakuma H
    Vasc Endovascular Surg; 2024 Apr; 58(4):457-460. PubMed ID: 38019846
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [A case report of Stanford type A acute thrombosed aortic dissection complicating cardiac tamponade].
    Morimoto K; Kuroda H; Ashida Y; Hara Y; Ishiguro S; Mori T
    Nihon Kyobu Geka Gakkai Zasshi; 1996 Sep; 44(9):1805-8. PubMed ID: 8911061
    [TBL] [Abstract][Full Text] [Related]  