These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 27487904)

  • 1. Resolution recovery for Compton camera using origin ensemble algorithm.
    Andreyev A; Celler A; Ozsahin I; Sitek A
    Med Phys; 2016 Aug; 43(8):4866. PubMed ID: 27487904
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy.
    Yao Z; Xiao Y; Chen Z; Wang B; Hou Q
    Sci Rep; 2019 Feb; 9(1):1133. PubMed ID: 30718671
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A noise smoothing origin ensemble algorithm based on local filtering.
    Chiang CC; Lin HH; Ni YC; Jan ML; Chuang KS
    Phys Med Biol; 2019 Aug; 64(15):155020. PubMed ID: 31181555
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo evaluation of a LYSO-based Compton camera using two origin ensemble algorithms with resolution recovery.
    Huang HM
    Med Phys; 2021 Sep; 48(9):5300-5310. PubMed ID: 34260083
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fast image reconstruction for Compton camera using stochastic origin ensemble approach.
    Andreyev A; Sitek A; Celler A
    Med Phys; 2011 Jan; 38(1):429-38. PubMed ID: 21361211
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging.
    Ouyang J; El Fakhri G; Moore SC
    Med Phys; 2007 Aug; 34(8):3263-72. PubMed ID: 17879789
    [TBL] [Abstract][Full Text] [Related]  

  • 7. PSF reconstruction for Compton-based prompt gamma imaging.
    Jan ML; Lee MW; Huang HM
    Phys Med Biol; 2018 Jan; 63(3):035015. PubMed ID: 29189207
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noise evaluation of Compton camera imaging for proton therapy.
    Ortega PG; Torres-Espallardo I; Cerutti F; Ferrari A; Gillam JE; Lacasta C; Llosá G; Oliver JF; Sala PR; Solevi P; Rafecas M
    Phys Med Biol; 2015 Mar; 60(5):1845-63. PubMed ID: 25658644
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.
    Kalantari F; Rajabi H; Saghari M
    Nucl Med Commun; 2012 Mar; 33(3):228-38. PubMed ID: 22134173
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiopharmaceutical imaging based on 3D-CZT Compton camera with 3D-printed mouse phantom.
    Tian F; Geng C; Yao Z; Wu R; Xu J; Cai F; Tang X
    Phys Med; 2022 Apr; 96():140-148. PubMed ID: 35287101
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization of Image Reconstruction for
    Rowley LM; Bradley KM; Boardman P; Hallam A; McGowan DR
    J Nucl Med; 2017 Apr; 58(4):658-664. PubMed ID: 27688476
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of Origin Ensemble algorithm for image reconstruction for pixelated solid-state detectors with large number of channels.
    Kolstein M; De Lorenzo G; Mikhaylova E; Chmeissani M; Ariño G; Calderón Y; Ozsahin I; Uzun D
    J Instrum; 2013 Apr; 8():. PubMed ID: 23814604
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of ray profile modeling on resolution recovery in clinical CT.
    Hofmann C; Knaup M; Kachelrieß M
    Med Phys; 2014 Feb; 41(2):021907. PubMed ID: 24506628
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization.
    Dong X; Niu T; Zhu L
    Med Phys; 2014 May; 41(5):051909. PubMed ID: 24784388
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reconstruction of multiple-pinhole micro-SPECT data using origin ensembles.
    Lyon MC; Sitek A; Metzler SD; Moore SC
    Med Phys; 2016 Oct; 43(10):5475. PubMed ID: 27782695
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction.
    Merlin T; Visvikis D; Fernandez P; Lamare F
    Med Phys; 2015 Feb; 42(2):804-19. PubMed ID: 25652494
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The SRT reconstruction algorithm for semiquantification in PET imaging.
    Kastis GA; Gaitanis A; Samartzis AP; Fokas AS
    Med Phys; 2015 Oct; 42(10):5970-82. PubMed ID: 26429272
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment.
    Riddell C; Carson RE; Carrasquillo JA; Libutti SK; Danforth DN; Whatley M; Bacharach SL
    J Nucl Med; 2001 Sep; 42(9):1316-23. PubMed ID: 11535719
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bone SPECT image reconstruction using deconvolution and wavelet transformation: development, performance assessment and comparison in phantom and patient study with standard OSEM and resolution recovery algorithm.
    Ptáček J; Henzlová L; Koranda P
    Phys Med; 2014 Nov; 30(7):858-64. PubMed ID: 24989849
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A practical way to improve contrast-to-noise ratio and quantitation for statistical-based iterative reconstruction in whole-body PET imaging.
    Fin L; Bailly P; Daouk J; Meyer ME
    Med Phys; 2009 Jul; 36(7):3072-9. PubMed ID: 19673206
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.