These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 27488284)

  • 1. Angioscopic Assessment of Stent Stability and Neointimal Coverage After Implantation of 2nd-Generation Drug-Eluting Stents - Comparison With Bare-Mental Stents and 1st-Generation Drug-Eluting Stents.
    Kimura S
    Circ J; 2016 Aug; 80(9):1895-7. PubMed ID: 27488284
    [No Abstract]   [Full Text] [Related]  

  • 2. Comparison of Chronic Angioscopic Findings of Bare Metal Stents, 1st-Generation Drug-Eluting Stents and 2nd-Generation Drug-Eluting Stents - Multicenter Study of Intra-Coronary Angioscopy After Stent (MICASA).
    Dai K; Matsuoka H; Kawakami H; Sato T; Watanabe K; Nakama Y; Ishihara M
    Circ J; 2016 Aug; 80(9):1916-21. PubMed ID: 27357218
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Serial angioscopic evaluation of neointimal coverage and incidence of thrombus formation after Paclitaxel-eluting stent implantation: comparison between 6- and 18-month follow-up.
    Hara M; Nishino M; Taniike M; Makino N; Kato H; Egami Y; Shutta R; Tanouchi J; Yamada Y
    Clin Cardiol; 2011 May; 34(5):322-6. PubMed ID: 21432859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Angioscopic evaluation after venous stents.
    Hoshino Y; Yokoi H
    J Vasc Surg Venous Lymphat Disord; 2023 Jan; 11(1):136-142. PubMed ID: 35931362
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings.
    Kotani J; Awata M; Nanto S; Uematsu M; Oshima F; Minamiguchi H; Mintz GS; Nagata S
    J Am Coll Cardiol; 2006 May; 47(10):2108-11. PubMed ID: 16697331
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel neointimal formation over sirolimus-eluting stents identified by coronary angioscopy and optical coherence tomography.
    Murakami D; Takano M; Yamamoto M; Inami S; Ohba T; Seino Y; Mizuno K
    J Cardiol; 2009 Apr; 53(2):311-3. PubMed ID: 19304139
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents.
    Awata M; Kotani J; Uematsu M; Morozumi T; Watanabe T; Onishi T; Iida O; Sera F; Nanto S; Hori M; Nagata S
    Circulation; 2007 Aug; 116(8):910-6. PubMed ID: 17684153
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Degree of neointimal coverage is not related to prevalence of in-stent thrombosis in drug-eluting stents: a coronary angioscopic study.
    Takayama T; Hiro T; Akabane M; Kawano T; Ichikawa M; Kanai T; Fukamachi D; Haruta H; Saito S; Hirayama A
    Int J Cardiol; 2012 Apr; 156(2):224-6. PubMed ID: 22330006
    [No Abstract]   [Full Text] [Related]  

  • 9. Comparison of angioscopic findings and three-year cardiac events between sirolimus-eluting stent and bare-metal stent in acute myocardial infarction.
    Nishino M; Yoshimura T; Nakamura D; Lee Y; Taniike M; Makino N; Kato H; Egami Y; Shutta R; Tanouchi J; Yamada Y
    Am J Cardiol; 2011 Nov; 108(9):1238-43. PubMed ID: 21840490
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differential angioscopic findings of neointimal coverage among first-, second-, and next generation drug-eluting stents.
    Nakayoshi T; Ueno T; Sasaki KI; Yokoyama S; Ohtsuka M; Mitsutake Y; Itaya N; Chibana H; Sasaki M; Ishimatsu T; Kimura T; Fukumoto Y
    Int J Cardiol; 2016 Nov; 223():450-451. PubMed ID: 27544603
    [No Abstract]   [Full Text] [Related]  

  • 11. A case of a newly developed yellow neointima at stent implanted site 1 year after sirolimus-eluting stent placement: angioscopic findings.
    Kawakami H; Matsuoka H; Oshita A; Kono T; Shigemi S
    J Cardiol; 2009 Aug; 54(1):153-7. PubMed ID: 19632537
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: an angioscopic study.
    Higo T; Ueda Y; Oyabu J; Okada K; Nishio M; Hirata A; Kashiwase K; Ogasawara N; Hirotani S; Kodama K
    JACC Cardiovasc Imaging; 2009 May; 2(5):616-24. PubMed ID: 19442950
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Serial changes of coronary endothelial function and arterial healing after paclitaxel-eluting stent implantation.
    Mitsutake Y; Ueno T; Ikeno F; Yokoyama S; Sasaki K; Nakayoshi T; Itaya N; Chibana H; Sasaki M; Fukumoto Y
    Cardiovasc Interv Ther; 2016 Jan; 31(1):21-8. PubMed ID: 26113198
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Angioscopic findings after drug-eluting stent implantation.
    Takano M; Mizuno K
    Herz; 2007 Jun; 32(4):281-6. PubMed ID: 17607534
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Angioscopic Comparison of Resolute and Endeavor Zotarolimus-Eluting Stents.
    Nishimoto Y; Matsuo K; Ueda Y; Sugihara R; Hirata A; Murakami A; Kashiwase K; Higuchi Y; Yasumura Y
    Circ J; 2016; 80(3):650-6. PubMed ID: 26794153
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Angioscopic evaluation of neointima coverage: sirolimus drug-eluting stent versus bare metal stent.
    Oyabu J; Ueda Y; Ogasawara N; Okada K; Hirayama A; Kodama K
    Am Heart J; 2006 Dec; 152(6):1168-74. PubMed ID: 17161071
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Extensive arterial repair one year after paclitaxel-coated nitinol drug-eluting stent vs. bare-metal stent implantation in the superficial femoral artery.
    Ishihara T; Iida O; Awata M; Nanto K; Shiraki T; Okamoto S; Iida T; Fujita M; Watanabe T; Nanto S; Uematsu M
    Cardiovasc Interv Ther; 2015 Jan; 30(1):51-6. PubMed ID: 25085265
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In-stent neointimal characteristics and late neointimal response after drug-eluting stent implantation: A preliminary observation.
    Fukuhara K; Okura H; Kume T; Yamada R; Neishi Y; Uemura S
    J Cardiol; 2016 May; 67(5):437-41. PubMed ID: 26276105
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The wound healing response after implantation of a drug-eluting stent is impaired persistently in the long term.
    Nasuno T; Tokura M; Kageyama M; Toyoda S; Sakuma M; Komatsu T; Taguchi I; Abe S; Inoue T
    Heart Vessels; 2016 Jun; 31(6):985-9. PubMed ID: 25939630
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Evaluation of very early neointimal coverage post drug-eluting stent implantation using optical coherence tomography].
    Wang TJ; Yang YJ; Xu B; Xu L; Sun ZW; Ma C; Tang Y; Tian Y; Yuan WM; Chu Y
    Zhonghua Xin Xue Guan Bing Za Zhi; 2012 Sep; 40(9):747-51. PubMed ID: 23141086
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.