These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 27490951)

  • 1. Feasibility and reliability of carotid intima-media thickness measurements in nonsedated infants.
    Mivelaz Y; Di Bernardo S; Boulos Ksontini T; Prsa M; Vial Y; Chiolero A; Sekarski N
    J Hypertens; 2016 Nov; 34(11):2227-32. PubMed ID: 27490951
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Carotid artery intima-media thickness measurements in the youth: reproducibility and technical considerations.
    Selamet Tierney ES; Gauvreau K; Jaff MR; Gal D; Nourse SE; Trevey S; O'Neill S; Baker A; Newburger JW; Colan SD
    J Am Soc Echocardiogr; 2015 Mar; 28(3):309-16. PubMed ID: 25459501
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Manual or semi-automated edge detection of the maximal far wall common carotid intima-media thickness: a direct comparison.
    Peters SA; den Ruijter HM; Palmer MK; Grobbee DE; Crouse JR; O'Leary DH; Evans GW; Raichlen JS; Lind L; Bots ML;
    J Intern Med; 2012 Mar; 271(3):247-56. PubMed ID: 21726301
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reproducibility of aortic intima-media thickness in infants using edge-detection software and manual caliper measurements.
    McCloskey K; Ponsonby AL; Carlin JB; Jachno K; Cheung M; Skilton MR; Koleff J; Vuillermin P; Burgner D;
    Cardiovasc Ultrasound; 2014 Jun; 12():18. PubMed ID: 24894574
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated ultrasound edge-tracking software comparable to established semi-automated reference software for carotid intima-media thickness analysis.
    Shenouda N; Proudfoot NA; Currie KD; Timmons BW; MacDonald MJ
    Clin Physiol Funct Imaging; 2018 May; 38(3):396-401. PubMed ID: 28444941
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ultrasound measurements of carotid intima-media thickness by two semi-automated analysis systems.
    Ring M; Eriksson MJ; Jogestrand T; Caidahl K
    Clin Physiol Funct Imaging; 2016 Sep; 36(5):389-95. PubMed ID: 26046377
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fully automated on-screen carotid intima-media thickness measurement: a screening tool for subclinical atherosclerosis.
    Vanoli D; Lindqvist P; Wiklund U; Henein M; Näslund U
    J Clin Ultrasound; 2013; 41(6):333-9. PubMed ID: 23553729
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Risk factors during first 1,000 days of life for carotid intima-media thickness in infants, children, and adolescents: A systematic review with meta-analyses.
    Epure AM; Rios-Leyvraz M; Anker D; Di Bernardo S; da Costa BR; Chiolero A; Sekarski N
    PLoS Med; 2020 Nov; 17(11):e1003414. PubMed ID: 33226997
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inter- and intra-observer variability analysis of completely automated cIMT measurement software (AtheroEdge™) and its benchmarking against commercial ultrasound scanner and expert Readers.
    Saba L; Molinari F; Meiburger KM; Acharya UR; Nicolaides A; Suri JS
    Comput Biol Med; 2013 Sep; 43(9):1261-72. PubMed ID: 23930821
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Changes in carotid artery intima-media thickness during the cardiac cycle - a comparative study in early childhood, mid-childhood, and adulthood.
    Rueb K; Mynard J; Liu R; Wake M; Vuillermin P; Ponsonby AL; Zannino D; Burgner DP
    Vasa; 2017 Jul; 46(4):275-281. PubMed ID: 28332441
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system.
    Potter K; Green DJ; Reed CJ; Woodman RJ; Watts GF; McQuillan BM; Burke V; Hankey GJ; Arnolda LF
    Cardiovasc Ultrasound; 2007 Sep; 5():29. PubMed ID: 17892537
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High-resolution radial artery intima-media thickness and cardiovascular risk factors in patients with suspected coronary artery disease--comparison with common carotid artery intima-media thickness.
    Eklund C; Friberg P; Gan LM
    Atherosclerosis; 2012 Mar; 221(1):118-23. PubMed ID: 22265271
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Carotid intima-media thickness and plaque assessment by trained medical residents: validation and preliminary testing of a training protocol.
    Aldridge ME; Do K; Oo T; Naqvi TZ
    J Am Soc Echocardiogr; 2013 Dec; 26(12):1457-64. PubMed ID: 24050846
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison between automated and manual measurements of carotid intima-media thickness in clinical practice.
    Freire CM; Ribeiro AL; Barbosa FB; Nogueira AI; de Almeida MC; Barbosa MM; Lana AM; e Silva AC; Ribeiro-Oliveira A
    Vasc Health Risk Manag; 2009; 5():811-7. PubMed ID: 19812693
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Validation of an Open-Source Tool for Measuring Carotid Lumen Diameter and Intima-Media Thickness.
    Manterola HL; Lo Vercio L; Díaz A; Del Fresno M; Larrabide I
    Ultrasound Med Biol; 2018 Aug; 44(8):1873-1881. PubMed ID: 29773245
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Variations in carotid artery intima-media thickness during the cardiac cycle in children.
    Menees S; Zhang D; Le J; Chen J; Raghuveer G
    J Am Soc Echocardiogr; 2010 Jan; 23(1):58-63. PubMed ID: 19962856
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The changes of individual carotid artery wall layer by aging and carotid intima-media thickness value for high risk.
    Bae JH; Kim WS; Lee MS; Kim KS; Park JB; Youn HJ; Park CG; Hong KS; Kim JY; Jeong JW; Park JC; Lim DS; Kim MH; Woo JT
    Cardiovasc Ther; 2016 Dec; 34(6):397-403. PubMed ID: 27420293
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biologically implausible carotid intima-media thickness measurement values: effects on rate of change over time.
    Peters SA; den Ruijter HM; Palmer MK; Grobbee DE; Crouse JR; O'Leary DH; Evans GW; Raichlen JS; Bots ML;
    Curr Med Res Opin; 2012 Jun; 28(6):891-9. PubMed ID: 22536884
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of semi-automated and manual measurements of carotid intima-media thickening.
    Mac Ananey O; Mellotte G; Maher V
    Biomed Res Int; 2014; 2014():531389. PubMed ID: 24579082
    [TBL] [Abstract][Full Text] [Related]  

  • 20. What is the correct distance measurement metric when measuring carotid ultrasound intima-media thickness automatically?
    Saba L; Molinari F; Meiburger KM; Piga M; Zeng G; Rajendra Achraya U; Nicolaides A; Suri JS
    Int Angiol; 2012 Oct; 31(5):483-9. PubMed ID: 22990512
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.