These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 27496792)

  • 41. Decline in haemoglobin A1c values in diabetic patients receiving interferon-alpha and ribavirin for chronic hepatitis C.
    Greenberg PD; Rosman AS; Eldeiry LS; Naqvi Z; Bräu N
    J Viral Hepat; 2006 Sep; 13(9):613-7. PubMed ID: 16907848
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Hemoglobin Sherwood Forest detected by high performance liquid chromatography for hemoglobin A1c.
    Schnedl WJ; Reisinger EC; Pieber TR; Lipp RW; Schreiber F; Hopmeier P; Krejs GJ
    Am J Clin Pathol; 1995 Oct; 104(4):444-6. PubMed ID: 7572795
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A spurious haemoglobin A(1c) result associated with double heterozygote for haemoglobin Raleigh (β1[NA1]Val → Ala) and α(+)-thalassaemia.
    Singha K; Fucharoen G; Chaibunruang A; Netnee P; Fucharoen S
    Ann Clin Biochem; 2012 Sep; 49(Pt 5):445-9. PubMed ID: 22829696
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Hb Kalundborg [β79(EF3)Asp→Glu;
    Ahmad-Nielsen EB; Szecsi PB; Bratholm PS; Petersen J; Glenthøj A
    Hemoglobin; 2022 Mar; 46(2):124-128. PubMed ID: 35920343
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Limits of chromatographic determination of glycated hemoglobin (Hb A1c) in diabetes mellitus in presence of abnormal hemoglobins].
    Pashintseva LP; Budantseva TA; Troitskaia OV; Orlova EV; Kleshcheva LV
    Klin Lab Diagn; 2001 Jul; (7):39-43. PubMed ID: 11530531
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method.
    Chen D; Crimmins DL; Hsu FF; Lindberg FP; Scott MG
    Clin Chem; 1998 Jun; 44(6 Pt 1):1296-301. PubMed ID: 9625056
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c.
    Khuu HM; Robinson CA; Goolsby K; Hardy RW; Konrad RJ
    Arch Pathol Lab Med; 1999 Sep; 123(9):763-7. PubMed ID: 10458820
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Identification of a rare variant haemoglobin (Hb Sinai-Baltimore) causing spuriously low haemoglobin A(1c) values on ion exchange chromatography.
    Smith G; Murray H; Brennan SO
    Ann Clin Biochem; 2013 Jan; 50(Pt 1):83-6. PubMed ID: 23129722
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Measurement of hemoglobin A1c by a new liquid-chromatographic assay: methodology, clinical utility, and relation to glucose tolerance evaluated.
    Jeppsson JO; Jerntorp P; Sundkvist G; Englund H; Nylund V
    Clin Chem; 1986 Oct; 32(10):1867-72. PubMed ID: 3757206
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A case of a novel hemoglobin variant, Hb A2-Karatsu, discovered following a falsely elevated HbA1c value.
    Inoue S; Tsuruda S; Tsuruta A; Kishikawa M; Yamazaki K; Ibaraki K; Yamashiro Y; Koga M
    Clin Chim Acta; 2022 Dec; 537():154-157. PubMed ID: 36283494
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A rare haemoglobin variant (Hb Phnom Penh) manifesting as a falsely high haemoglobin A1c value on ion-exchange chromatography.
    Chen CF; Tai YK
    Singapore Med J; 2014 Aug; 55(8):e126-8. PubMed ID: 25189312
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.
    Sadriani N; Marpaung FR
    Biochem Med (Zagreb); 2023 Oct; 33(3):030801. PubMed ID: 37841770
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Hb Ullevaal [β78(EF2)Leu→Val; HBB: c.235C>G], a new hemoglobin variant interfering with Hb A1c measurement using a cation exchange high performance liquid chromatography method.
    Grimholt RM; Sudmann ÅA; Piehler AP; Urdal P; Klingenberg O
    Hemoglobin; 2014; 38(2):130-2. PubMed ID: 24274186
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Evaluation and interference study of hemoglobin A1c measured by turbidimetric inhibition immunoassay.
    Chang J; Hoke C; Ettinger B; Penerian G
    Am J Clin Pathol; 1998 Mar; 109(3):274-8. PubMed ID: 9495198
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Aberrantly high glycated haemoglobin measurement due to the haemoglobin variant Hb Santa Juana.
    Ng HL; Koh CK
    Singapore Med J; 2011 Apr; 52(4):e75-8. PubMed ID: 21552778
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A comparative evaluation of glycosylated haemoglobin assays: feasibility of references and standards.
    Peterson CM; Jovanovic L; Raskin P; Goldstein DE
    Diabetologia; 1984 Mar; 26(3):214-7. PubMed ID: 6714539
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Determination of haemoglobin A1c levels using high-performance liquid chromatography of bloodstains.
    Acar K; Kurtulus Dereli A; Avci E; Zeybek V; Kutlu E; Demir S; Senol H
    Med Sci Law; 2020 Jan; 60(1):19-25. PubMed ID: 31645182
    [No Abstract]   [Full Text] [Related]  

  • 58. A rare hemoglobin variant (Hb Iraq-Halabja) causing spuriously low hemoglobin A1c values.
    Chen CF; Chien CM; Liu SC; Tai YK
    Intern Med; 2013; 52(21):2443-6. PubMed ID: 24190149
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Interference of the most frequent haemoglobin variants on quantification of HbA1c: comparison between the LC-MS (IFCC reference method) and three routinely used methods.
    Jaisson S; Leroy N; Desroches C; Tonye-Libyh M; Guillard E; Gillery P
    Diabetes Metab; 2013 Sep; 39(4):363-9. PubMed ID: 23639569
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of Hb A1c Quantification in the Presence of Hemoglobin Variants of an HPLC Assay with an Enzymatic Assay.
    Nichols JH; Berman M; Carrillo A; Manning S
    J Appl Lab Med; 2023 Nov; 8(6):1127-1132. PubMed ID: 37610380
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.