These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

393 related articles for article (PubMed ID: 27497594)

  • 1. Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC.
    Fritz J; Fritz B; Thawait GK; Raithel E; Gilson WD; Nittka M; Mont MA
    Skeletal Radiol; 2016 Oct; 45(10):1345-56. PubMed ID: 27497594
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants.
    Fritz J; Ahlawat S; Demehri S; Thawait GK; Raithel E; Gilson WD; Nittka M
    Invest Radiol; 2016 Oct; 51(10):666-76. PubMed ID: 27518214
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Instrument visualization using conventional and compressed sensing SEMAC for interventional MRI at 3T.
    Sonnow L; Gilson WD; Raithel E; Nittka M; Wacker F; Fritz J
    J Magn Reson Imaging; 2018 May; 47(5):1306-1315. PubMed ID: 28940951
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metal artifact reduction MRI of total ankle arthroplasty implants.
    de Cesar Netto C; Fonseca LF; Fritz B; Stern SE; Raithel E; Nittka M; Schon LC; Fritz J
    Eur Radiol; 2018 May; 28(5):2216-2227. PubMed ID: 29218618
    [TBL] [Abstract][Full Text] [Related]  

  • 5. SEMAC-VAT and MSVAT-SPACE sequence strategies for metal artifact reduction in 1.5T magnetic resonance imaging.
    Ai T; Padua A; Goerner F; Nittka M; Gugala Z; Jadhav S; Trelles M; Johnson RF; Lindsey RW; Li X; Runge VM
    Invest Radiol; 2012 May; 47(5):267-76. PubMed ID: 22266987
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved Visualization of Juxtaprosthetic Tissue Using Metal Artifact Reduction Magnetic Resonance Imaging: Experimental and Clinical Optimization of Compressed Sensing SEMAC.
    Jungmann PM; Bensler S; Zingg P; Fritz B; Pfirrmann CW; Sutter R
    Invest Radiol; 2019 Jan; 54(1):23-31. PubMed ID: 30351283
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of metal artifacts in clinical MR images of patients with total hip arthroplasty using different metal artifact-reducing sequences.
    Müller GM; Lundin B; von Schewelov T; Müller MF; Ekberg O; Månsson S
    Skeletal Radiol; 2015 Mar; 44(3):353-9. PubMed ID: 25472553
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T
    Lee YH; Hahn S; Kim E; Suh JS
    Magn Reson Med Sci; 2016 Oct; 15(4):371-378. PubMed ID: 26902679
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration.
    Otazo R; Nittka M; Bruno M; Raithel E; Geppert C; Gyftopoulos S; Recht M; Rybak L
    Magn Reson Med; 2017 Jul; 78(1):79-87. PubMed ID: 27454003
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Usefulness of slice encoding for metal artifact correction (SEMAC) for reducing metallic artifacts in 3-T MRI.
    Lee YH; Lim D; Kim E; Kim S; Song HT; Suh JS
    Magn Reson Imaging; 2013 Jun; 31(5):703-6. PubMed ID: 23290476
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New-Generation Low-Field Magnetic Resonance Imaging of Hip Arthroplasty Implants Using Slice Encoding for Metal Artifact Correction: First In Vitro Experience at 0.55 T and Comparison With 1.5 T.
    Khodarahmi I; Brinkmann IM; Lin DJ; Bruno M; Johnson PM; Knoll F; Keerthivasan MB; Chandarana H; Fritz J
    Invest Radiol; 2022 Aug; 57(8):517-526. PubMed ID: 35239614
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-Dimensional CAIPIRINHA SPACE TSE for 5-Minute High-Resolution MRI of the Knee.
    Fritz J; Fritz B; Thawait GG; Meyer H; Gilson WD; Raithel E
    Invest Radiol; 2016 Oct; 51(10):609-17. PubMed ID: 27187045
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization of Scan Time in MRI for Total Hip Prostheses: SEMAC Tailoring for Prosthetic Implants Containing Different Types of Metals.
    Deligianni X; Bieri O; Elke R; Wischer T; Egelhof T
    Rofo; 2015 Dec; 187(12):1116-22. PubMed ID: 26327671
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Total knee arthroplasty MRI featuring slice-encoding for metal artifact correction: reduction of artifacts for STIR and proton density-weighted sequences.
    Sutter R; Hodek R; Fucentese SF; Nittka M; Pfirrmann CW
    AJR Am J Roentgenol; 2013 Dec; 201(6):1315-24. PubMed ID: 24261373
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.
    Park C; Lee E; Yeo Y; Kang Y; Lee JW; Ahn JM; Kang HS
    Magn Reson Imaging; 2018 Dec; 54():63-70. PubMed ID: 30099060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Compressed Sensing SEMAC MRI of Hip, Knee, and Ankle Arthroplasty Implants: A 1.5-T and 3-T Intrapatient Performance Comparison for Diagnosing Periprosthetic Abnormalities.
    Khodarahmi I; Khanuja HS; Stern SE; Carrino JA; Fritz J
    AJR Am J Roentgenol; 2023 Nov; 221(5):661-672. PubMed ID: 37255041
    [No Abstract]   [Full Text] [Related]  

  • 17. Off-resonance suppression for multispectral MR imaging near metallic implants.
    den Harder JC; van Yperen GH; Blume UA; Bos C
    Magn Reson Med; 2015 Jan; 73(1):233-43. PubMed ID: 24488684
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparison of Image Quality Using Metal Artifact Reduction Magnetic Resonance Sequences at Different Static Magnetic Fields].
    Otomo S; Sagawa H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2023 Jul; 79(7):693-700. PubMed ID: 37225450
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3T.
    Lee YH; Lim D; Kim E; Kim S; Song HT; Suh JS
    Magn Reson Imaging; 2014 Oct; 32(8):1001-5. PubMed ID: 24925839
    [TBL] [Abstract][Full Text] [Related]  

  • 20. View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application.
    Jungmann PM; Ganter C; Schaeffeler CJ; Bauer JS; Baum T; Meier R; Nittka M; Pohlig F; Rechl H; von Eisenhart-Rothe R; Rummeny EJ; Woertler K
    PLoS One; 2015; 10(4):e0124922. PubMed ID: 25909472
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.