304 related articles for article (PubMed ID: 27499370)
1. Comparison between beta radiation dose distribution due to LDR and HDR ocular brachytherapy applicators using GATE Monte Carlo platform.
Mostafa L; Rachid K; Ahmed SM
Phys Med; 2016 Aug; 32(8):1007-18. PubMed ID: 27499370
[TBL] [Abstract][Full Text] [Related]
2. Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye.
Cross WG; Hokkanen J; Järvinen H; Mourtada F; Sipilä P; Soares CG; Vynckier S
Med Phys; 2001 Jul; 28(7):1385-96. PubMed ID: 11488569
[TBL] [Abstract][Full Text] [Related]
3. Calculation of dose distributions for 12 106Ru/106Rh ophthalmic applicator models with the PENELOPE Monte Carlo code.
Hermida-López M
Med Phys; 2013 Oct; 40(10):101705. PubMed ID: 24089895
[TBL] [Abstract][Full Text] [Related]
4. A Monte Carlo dose calculation system for ophthalmic brachytherapy based on a realistic eye model.
Miras Del Río H; Ortiz Lora A; Bertolet Reina A; Terrón León JA
Med Phys; 2021 Aug; 48(8):4542-4559. PubMed ID: 34250607
[TBL] [Abstract][Full Text] [Related]
5. An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions.
Rivard MJ; Melhus CS; Granero D; Perez-Calatayud J; Ballester F
Med Phys; 2009 Jun; 36(6):1968-75. PubMed ID: 19610285
[TBL] [Abstract][Full Text] [Related]
6. Development of prototype shielded cervical intracavitary brachytherapy applicators compatible with CT and MR imaging.
Price MJ; Jackson EF; Gifford KA; Eifel PJ; Mourtada F
Med Phys; 2009 Dec; 36(12):5515-24. PubMed ID: 20095264
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo calculation of the dose distributions of two 106Ru eye applicators.
Sánchez-Reyes A; Tello JI; Guix B; Salvat F
Radiother Oncol; 1998 Nov; 49(2):191-6. PubMed ID: 10052886
[TBL] [Abstract][Full Text] [Related]
8. Dosimetric assessment of an air-filled balloon applicator in HDR vaginal cuff brachytherapy using the Monte Carlo method.
Jiang H; Badkul R; Pokhrel D
J Appl Clin Med Phys; 2018 May; 19(3):101-107. PubMed ID: 29493101
[TBL] [Abstract][Full Text] [Related]
9. A patch source model for treatment planning of ruthenium ophthalmic applicators.
Astrahan MA
Med Phys; 2003 Jun; 30(6):1219-28. PubMed ID: 12852546
[TBL] [Abstract][Full Text] [Related]
10. Ocular brachytherapy dosimetry for 103Pd and 125I in the presence of gold nanoparticles: a Monte Carlo study.
Asadi S; Vaez-Zadeh M; Vahidian M; Marghchouei M; Masoudi SF
J Appl Clin Med Phys; 2016 May; 17(3):90-99. PubMed ID: 27167265
[TBL] [Abstract][Full Text] [Related]
11. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom.
Lesperance M; Inglis-Whalen M; Thomson RM
Med Phys; 2014 Feb; 41(2):021717. PubMed ID: 24506608
[TBL] [Abstract][Full Text] [Related]
12. 106Ru/106Rh plaque and proton radiotherapy for ocular melanoma: a comparative dosimetric study.
Mourtada F; Koch N; Newhauser W
Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):454-60. PubMed ID: 16604677
[TBL] [Abstract][Full Text] [Related]
13. The use of tetrahedral mesh geometries in Monte Carlo simulation of applicator based brachytherapy dose distributions.
Fonseca GP; Landry G; White S; D'Amours M; Yoriyaz H; Beaulieu L; Reniers B; Verhaegen F
Phys Med Biol; 2014 Oct; 59(19):5921-35. PubMed ID: 25210788
[TBL] [Abstract][Full Text] [Related]
14. Dosimetry of (125)I and (103)Pd COMS eye plaques for intraocular tumors: report of Task Group 129 by the AAPM and ABS.
Chiu-Tsao ST; Astrahan MA; Finger PT; Followill DS; Meigooni AS; Melhus CS; Mourtada F; Napolitano ME; Nath R; Rivard MJ; Rogers DW; Thomson RM
Med Phys; 2012 Oct; 39(10):6161-84. PubMed ID: 23039655
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources.
Fulkerson RK; Micka JA; DeWerd LA
Med Phys; 2014 Feb; 41(2):022104. PubMed ID: 24506636
[TBL] [Abstract][Full Text] [Related]
16. Gold nanoparticle-based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye.
Asadi S; Vaez-zadeh M; Masoudi SF; Rahmani F; Knaup C; Meigooni AS
J Appl Clin Med Phys; 2015 Sep; 16(5):344–357. PubMed ID: 26699318
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo simulation of COMS ophthalmic applicators loaded with Bebig I25.S16 seeds and comparison with planning system predictions.
Miras H; Terrón JA; Lallena AM
Phys Med; 2013 Nov; 29(6):670-6. PubMed ID: 22858007
[TBL] [Abstract][Full Text] [Related]
18. HDR brachytherapy of rectal cancer using a novel grooved-shielding applicator design.
Webster MJ; Devic S; Vuong T; Han DY; Scanderbeg D; Choi D; Song B; Song WY
Med Phys; 2013 Sep; 40(9):091704. PubMed ID: 24007137
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric characterization of round HDR 192Ir accuboost applicators for breast brachytherapy.
Rivard MJ; Melhus CS; Wazer DE; Bricault RJ
Med Phys; 2009 Nov; 36(11):5027-32. PubMed ID: 19994513
[TBL] [Abstract][Full Text] [Related]
20. Fluorescence 125I eye applicator.
Bambynek M; Flühs D; Heintz M; Kolanoski H; Wegener D; Quast U
Med Phys; 1999 Nov; 26(11):2476-81. PubMed ID: 10587236
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]