These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
192 related articles for article (PubMed ID: 27499777)
1. Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence. HarsimranKaur VN; Selhi PK; Sood N; Singh A Iran J Pathol; 2016; 11(2):151-4. PubMed ID: 27499777 [TBL] [Abstract][Full Text] [Related]
2. Finish before the start: Analyzing preanalytical sample errors in a tertiary care hematology laboratory. Gaur K; Puri V; Shukla S; Sharma S; Suman S; Singh R Indian J Pathol Microbiol; 2020; 63(3):435-440. PubMed ID: 32769334 [TBL] [Abstract][Full Text] [Related]
3. Preanalytical Errors in Hematology: Insights From a Tertiary Care Hospital. Kani V; Kannan K; Arumugam S; Sonti S Cureus; 2024 Sep; 16(9):e69641. PubMed ID: 39429359 [TBL] [Abstract][Full Text] [Related]
4. Preanalytical Errors in a Hematology Laboratory: An Experience from a Tertiary Care Center. Iqbal MS; Tabassum A; Arbaeen AF; Qasem AH; Elshemi AG; Almasmoum H Diagnostics (Basel); 2023 Feb; 13(4):. PubMed ID: 36832079 [TBL] [Abstract][Full Text] [Related]
5. Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India. Arul P; Pushparaj M; Pandian K; Chennimalai L; Rajendran K; Selvaraj E; Masilamani S J Lab Physicians; 2018; 10(2):237-240. PubMed ID: 29692594 [TBL] [Abstract][Full Text] [Related]
6. Detecting Preanalytical Errors Using Quality Indicators in a Hematology Laboratory. Alshaghdali K; Alcantara TY; Rezgui R; Cruz CP; Alshammary MH; Almotairi YA; Alcantara JC Qual Manag Health Care; 2022 Jul-Sep 01; 31(3):176-183. PubMed ID: 34483302 [TBL] [Abstract][Full Text] [Related]
7. An Overview of Complete Blood Count Sample Rejection Rates in a Clinical Hematology Laboratory Due to Various Preanalytical Errors. Noor T; Imran A; Raza H; Umer S; Malik NA; Chughtai AS Cureus; 2023 Jan; 15(1):e34444. PubMed ID: 36874705 [TBL] [Abstract][Full Text] [Related]
8. Quality indicators in the preanalytical phase of testing in a stat laboratory. Grecu DS; Vlad DC; Dumitrascu V Lab Med; 2014; 45(1):74-81. PubMed ID: 24719991 [TBL] [Abstract][Full Text] [Related]
9. The Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories. Cakirca G Iran J Pathol; 2018; 13(2):173-178. PubMed ID: 30697287 [TBL] [Abstract][Full Text] [Related]
10. Reducing preanalytical laboratory sample errors through educational and technological interventions. Lillo R; Salinas M; Lopez-Garrigos M; Naranjo-Santana Y; Gutiérrez M; Marín MD; Miralles M; Uris J Clin Lab; 2012; 58(9-10):911-7. PubMed ID: 23163106 [TBL] [Abstract][Full Text] [Related]
11. Challenges in Preanalytical Phase of Laboratory Medicine: Rate of Blood Sample Nonconformity in a Tertiary Care Hospital. Alavi N; Khan SH; Saadia A; Naeem T EJIFCC; 2020 Mar; 31(1):21-27. PubMed ID: 32256286 [TBL] [Abstract][Full Text] [Related]
12. [Quality assessment for preanalytical phase in clinical laboratory: a multicentric study]. Salinas M; López-Garrigós M; Yago M; Ortuño M; Carratala A; Aguado C; Díaz J; Rodriguez-Borja E; Chinchilla V; Esteban A; Laíz B; Lorente MÁ; Uris J Rev Calid Asist; 2011; 26(4):264-8. PubMed ID: 21621440 [TBL] [Abstract][Full Text] [Related]
13. Quality Indicators for Evaluating Errors in the Preanalytical Phase. Mehndiratta M; Pasha EH; Chandra N; Almeida EA J Lab Physicians; 2021 Jun; 13(2):169-174. PubMed ID: 34483565 [No Abstract] [Full Text] [Related]
14. The prevalence of preanalytical errors in a Croatian ISO 15189 accredited laboratory. Simundic AM; Nikolac N; Vukasovic I; Vrkic N Clin Chem Lab Med; 2010 Jul; 48(7):1009-14. PubMed ID: 20441481 [TBL] [Abstract][Full Text] [Related]
15. Preanalytical Errors in Clinical Biochemistry Laboratory and Relationship With Hospital Departments and Staff: A Record-Based Study. Dundar C; Bahadir O J Patient Saf; 2023 Jun; 19(4):239-242. PubMed ID: 36849433 [TBL] [Abstract][Full Text] [Related]
16. Monitoring and reporting of preanalytical errors in laboratory medicine: the UK situation. Cornes MP; Atherton J; Pourmahram G; Borthwick H; Kyle B; West J; Costelloe SJ Ann Clin Biochem; 2016 Mar; 53(Pt 2):279-84. PubMed ID: 26195485 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of Preanalytical Quality Indicators by Six Sigma and Pareto`s Principle. Kulkarni S; Ramesh R; Srinivasan AR; Silvia CRWD Indian J Clin Biochem; 2018 Jan; 33(1):102-107. PubMed ID: 29371778 [TBL] [Abstract][Full Text] [Related]
18. Spanish Preanalytical Quality Monitoring Program (SEQC), an overview of 12 years' experience. Llopis MA; Bauça JM; Barba N; Álvarez V; Ventura M; Ibarz M; Gómez-Rioja R; Marzana I; Puente JJ; Segovia M; Martinez D; Alsina MJ Clin Chem Lab Med; 2017 Mar; 55(4):530-538. PubMed ID: 27658151 [TBL] [Abstract][Full Text] [Related]
19. Preanalytical error occurrence rate in clinical chemistry laboratory of a public hospital in India. Singla P; Parkash AA; Bhattacharjee J Clin Lab; 2011; 57(9-10):749-52. PubMed ID: 22029191 [TBL] [Abstract][Full Text] [Related]
20. Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors. Atay A; Demir L; Cuhadar S; Saglam G; Unal H; Aksun S; Arslan B; Ozkan A; Sutcu R Biochem Med (Zagreb); 2014; 24(3):376-82. PubMed ID: 25351356 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]