These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 27499851)

  • 1. (13)C glucose labelling studies using 2D NMR are a useful tool for determining ex vivo whole organ metabolism during hypothermic machine perfusion of kidneys.
    Nath J; Smith T; Hollis A; Ebbs S; Canbilen SW; Tennant DA; Ready AR; Ludwig C
    Transplant Res; 2016; 5():7. PubMed ID: 27499851
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Metabolic differences between cold stored and machine perfused porcine kidneys: A
    Nath J; Smith TB; Patel K; Ebbs SR; Hollis A; Tennant DA; Ludwig C; Ready AR
    Cryobiology; 2017 Feb; 74():115-120. PubMed ID: 27919740
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Effects of Oxygenation on Ex Vivo Kidneys Undergoing Hypothermic Machine Perfusion.
    Patel K; Smith TB; Neil DAH; Thakker A; Tsuchiya Y; Higgs EB; Hodges NJ; Ready AR; Nath J; Ludwig C
    Transplantation; 2019 Feb; 103(2):314-322. PubMed ID: 30461718
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metabolomic analysis of perfusate during hypothermic machine perfusion of human cadaveric kidneys.
    Guy AJ; Nath J; Cobbold M; Ludwig C; Tennant DA; Inston NG; Ready AR
    Transplantation; 2015 Apr; 99(4):754-9. PubMed ID: 25222017
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel hypothermic machine perfusion system using a LifePort Kidney Transporter for the preservation of rat liver.
    Zeng C; Hu X; Wang Y; Zeng X; Xiong Y; Li L; Ye Q
    Exp Ther Med; 2018 Feb; 15(2):1410-1416. PubMed ID: 29434725
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid sampling microdialysis as a novel tool for parenchyma assessment during static cold storage and hypothermic machine perfusion in a translational ex vivo porcine kidney model.
    Hamaoui K; Gowers S; Damji S; Rogers M; Leong CL; Hanna G; Darzi A; Boutelle M; Papalois V
    J Surg Res; 2016 Jan; 200(1):332-45. PubMed ID: 26323367
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Metabolomic perfusate analysis during kidney machine perfusion: the pig provides an appropriate model for human studies.
    Nath J; Guy A; Smith TB; Cobbold M; Inston NG; Hodson J; Tennant DA; Ludwig C; Ready AR
    PLoS One; 2014; 9(12):e114818. PubMed ID: 25502759
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An ex vivo comparison of adenosine and lidocaine solution and University of Wisconsin solution for hypothermic machine perfusion of porcine kidneys: potential for development.
    Hamaoui K; Aftab A; Gowers S; Boutelle M; Cook T; Rudd D; Dobson GP; Papalois V
    J Surg Res; 2017 Feb; 208():219-229. PubMed ID: 27993213
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Discriminate liver warm ischemic injury during hypothermic machine perfusion by proton magnetic resonance spectroscopy: a study in a porcine model.
    Liu Q; Vekemans K; van Pelt J; Pirenne J; Himmelreich U; Heedfeld V; Wylin T; Brassil J; Monbaliu D; Dresselaers T
    Transplant Proc; 2009 Oct; 41(8):3383-6. PubMed ID: 19857754
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of Oxidative Stress and Metabolic Profile in a Preclinical Kidney Transplantation Model According to Different Preservation Modalities.
    Simona MS; Alessandra V; Emanuela C; Elena T; Michela M; Fulvia G; Vincenzo S; Ilaria B; Federica M; Eloisa A; Massimo A; Maristella G
    Int J Mol Sci; 2023 Jan; 24(2):. PubMed ID: 36674540
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of perfusate on liver viability during hypothermic machine perfusion.
    Jia JJ; Zhang J; Li JH; Chen XD; Jiang L; Zhou YF; He N; Xie HY; Zhou L; Zheng SS
    World J Gastroenterol; 2015 Aug; 21(29):8848-57. PubMed ID: 26269674
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of Oxygen During Long-term Hypothermic Machine Perfusion in a Porcine Model of Kidney Donation After Circulatory Death.
    Venema LH; Brat A; Moers C; 't Hart NA; Ploeg RJ; Hannaert P; Minor T; Leuvenink AHGD;
    Transplantation; 2019 Oct; 103(10):2057-2064. PubMed ID: 30951018
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intermittent Surface Oxygenation Results in Similar Mitochondrial Protection and Maintenance of Aerobic Metabolism as Compared to Continuous Oxygenation during Hypothermic Machine Kidney Machine Perfusion.
    Darius T; Vergauwen M; Maistriaux L; Evrard R; Schlegel A; Mueller M; O'Neil D; Southam A; Aydin S; Devresse A; De Meyer M; Gianello P; Ludwig C; Dutkowski P; Mourad M
    J Clin Med; 2023 May; 12(11):. PubMed ID: 37297930
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Oxygen Consumption by Warm Ischemia-Injured Porcine Kidneys in Hypothermic Static and Machine Preservation.
    Kaminski J; Delpech PO; Kaaki-Hosni S; Promeyrat X; Hauet T; Hannaert P
    J Surg Res; 2019 Oct; 242():78-86. PubMed ID: 31071608
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of normothermic and hypothermic perfusion in porcine kidneys donated after cardiac death.
    Blum MF; Liu Q; Soliman B; Dreher P; Okamoto T; Poggio ED; Goldfarb DA; Baldwin WM; Quintini C
    J Surg Res; 2017 Aug; 216():35-45. PubMed ID: 28807212
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inhibition of TXA synthesis with OKY-046 improves liver preservation by prolonged hypothermic machine perfusion in rats.
    Xu H; Lee CY; Clemens MG; Zhang JX
    J Gastroenterol Hepatol; 2008 Jul; 23(7 Pt 2):e212-20. PubMed ID: 17645480
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metabolism in the hypothermically perfused kidney. Production and utilization of lactate and utilization of acetate in the dog kidney.
    Lundstam S; Claes G; Jonsson O; Pettersson S; Scherstén T
    Eur Surg Res; 1976; 8(4):300-10. PubMed ID: 954786
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hypothermic machine perfusion of the liver: is it more complex than for the kidney?
    Monbaliu D; Heedfeld V; Liu Q; Wylin T; van Pelt J; Vekemans K; Pirenne J
    Transplant Proc; 2011 Nov; 43(9):3445-50. PubMed ID: 22099817
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Role of oxygenation in hypothermic machine perfusion of kidneys from heart beating donors.
    Gallinat A; Paul A; Efferz P; Lüer B; Swoboda S; Hoyer D; Minor T
    Transplantation; 2012 Oct; 94(8):809-13. PubMed ID: 22992766
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Islet isolation from juvenile porcine pancreas after 24-h hypothermic machine perfusion preservation.
    Taylor MJ; Baicu S; Greene E; Vazquez A; Brassil J
    Cell Transplant; 2010; 19(5):613-28. PubMed ID: 20149300
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.