These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
140 related articles for article (PubMed ID: 27505829)
1. Experimental comparison between speckle and grating-based imaging technique using synchrotron radiation X-rays. Kashyap Y; Wang H; Sawhney K Opt Express; 2016 Aug; 24(16):18664-73. PubMed ID: 27505829 [TBL] [Abstract][Full Text] [Related]
2. From synchrotron radiation to lab source: advanced speckle-based X-ray imaging using abrasive paper. Wang H; Kashyap Y; Sawhney K Sci Rep; 2016 Feb; 6():20476. PubMed ID: 26847921 [TBL] [Abstract][Full Text] [Related]
3. X-ray phase-contrast tomosynthesis for improved breast tissue discrimination. Schleede S; Bech M; Grandl S; Sztrókay A; Herzen J; Mayr D; Stockmar M; Potdevin G; Zanette I; Rack A; Weitkamp T; Pfeiffer F Eur J Radiol; 2014 Mar; 83(3):531-6. PubMed ID: 24387825 [TBL] [Abstract][Full Text] [Related]
4. Comparison of X-ray speckle-based imaging deflection retrieval algorithms for the optimization of radiation dose. Rouge-Labriet H; Quenot L; Bohic S; Fayard B; Paganin DM; Brun E; Berujon S Phys Med Biol; 2021 Mar; 66(6):065005. PubMed ID: 32268312 [TBL] [Abstract][Full Text] [Related]
5. Hard-X-ray dark-field imaging using a grating interferometer. Pfeiffer F; Bech M; Bunk O; Kraft P; Eikenberry EF; Brönnimann Ch; Grünzweig C; David C Nat Mater; 2008 Feb; 7(2):134-7. PubMed ID: 18204454 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of phase-contrast CT of breast tissue at conventional X-ray sources - presentation of selected findings. Grandl S; Willner M; Herzen J; Mayr D; Auweter SD; Hipp A; Pfeiffer F; Reiser M; Hellerhoff K Z Med Phys; 2013 Sep; 23(3):212-21. PubMed ID: 23489931 [TBL] [Abstract][Full Text] [Related]
7. Hard-X-ray directional dark-field imaging using the speckle scanning technique. Wang H; Kashyap Y; Sawhney K Phys Rev Lett; 2015 Mar; 114(10):103901. PubMed ID: 25815933 [TBL] [Abstract][Full Text] [Related]
8. X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source. Herzen J; Donath T; Beckmann F; Ogurreck M; David C; Mohr J; Pfeiffer F; Schreyer A Rev Sci Instrum; 2011 Nov; 82(11):113711. PubMed ID: 22128988 [TBL] [Abstract][Full Text] [Related]
9. Microbubbles as a scattering contrast agent for grating-based x-ray dark-field imaging. Velroyen A; Bech M; Malecki A; Tapfer A; Yaroshenko A; Ingrisch M; Cyran CC; Auweter SD; Nikolaou K; Reiser M; Pfeiffer F Phys Med Biol; 2013 Feb; 58(4):N37-46. PubMed ID: 23369954 [TBL] [Abstract][Full Text] [Related]
10. Coherence in X-ray physics. Lengeler B Naturwissenschaften; 2001 Jun; 88(6):249-60. PubMed ID: 11544952 [TBL] [Abstract][Full Text] [Related]
11. On the origin and nature of the grating interferometric dark-field contrast obtained with low-brilliance x-ray sources. Koenig T; Zuber M; Trimborn B; Farago T; Meyer P; Kunka D; Albrecht F; Kreuer S; Volk T; Fiederle M; Baumbach T Phys Med Biol; 2016 May; 61(9):3427-42. PubMed ID: 27046451 [TBL] [Abstract][Full Text] [Related]
12. Influence of diffuser grain size on the speckle tracking technique. Tian N; Jiang H; Li A; Liang D; Yan S; Zhang Z J Synchrotron Radiat; 2020 Jan; 27(Pt 1):146-157. PubMed ID: 31868747 [TBL] [Abstract][Full Text] [Related]
13. Virtual differential phase-contrast and dark-field imaging of x-ray absorption images via deep learning. Ge X; Yang P; Wu Z; Luo C; Jin P; Wang Z; Wang S; Huang Y; Niu T Bioeng Transl Med; 2023 Nov; 8(6):e10494. PubMed ID: 38023711 [TBL] [Abstract][Full Text] [Related]
14. Multi-contrast diffraction enhanced computed laminography at Beijing Synchrotron Radiation Facility. Fu J; Shi X; Yuan Q; Huang W; Guo W; Peng P Anal Bioanal Chem; 2018 Nov; 410(27):7221-7228. PubMed ID: 30171283 [TBL] [Abstract][Full Text] [Related]
15. Quantitative x-ray phase-contrast imaging using a single grating of comparable pitch to sample feature size. Morgan KS; Paganin DM; Siu KK Opt Lett; 2011 Jan; 36(1):55-7. PubMed ID: 21209685 [TBL] [Abstract][Full Text] [Related]
16. Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating. Marathe S; Shi X; Wojcik MJ; Macrander AT; Assoufid L J Vis Exp; 2016 Oct; (116):. PubMed ID: 27768076 [TBL] [Abstract][Full Text] [Related]
18. Nanoscale imaging of the bone cell network with synchrotron X-ray tomography: optimization of acquisition setup. Pacureanu A; Langer M; Boller E; Tafforeau P; Peyrin F Med Phys; 2012 Apr; 39(4):2229-38. PubMed ID: 22482644 [TBL] [Abstract][Full Text] [Related]
19. A tilted grating interferometer for full vector field differential x-ray phase contrast tomography. Rutishauser S; Donath T; David C; Pfeiffer F; Marone F; Modregger P; Stampanoni M Opt Express; 2011 Dec; 19(25):24890-6. PubMed ID: 22273882 [TBL] [Abstract][Full Text] [Related]
20. The second-order differential phase contrast and its retrieval for imaging with x-ray Talbot interferometry. Yang Y; Tang X Med Phys; 2012 Dec; 39(12):7237-53. PubMed ID: 23231275 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]