These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 2751606)

  • 1. A stochastic model for high-LET response for boron neutron capture therapy (BNCT).
    Wheeler FJ; Griebenow ML; Wessol DE; Nigg DW; Anderl RA
    Basic Life Sci; 1989; 50():165-78. PubMed ID: 2751606
    [No Abstract]   [Full Text] [Related]  

  • 2. Boron neutron capture therapy (BNCT): implications of neutron beam and boron compound characteristics.
    Wheeler FJ; Nigg DW; Capala J; Watkins PR; Vroegindeweij C; Auterinen I; Seppälä T; Bleuel D
    Med Phys; 1999 Jul; 26(7):1237-44. PubMed ID: 10435523
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of ionizing radiation on the blood-brain-barrier (BBB): considerations for the application of boron neutron capture therapy (BNCT) of brain tumors.
    Dorn RV; Spickard JH; Griebenow ML
    Basic Life Sci; 1989; 50():145-52. PubMed ID: 2751605
    [No Abstract]   [Full Text] [Related]  

  • 4. Blood-brain-barrier impairment after irradiation: implication in boron neutron capture therapy.
    Grégoire V; Keyeux A; Wambersie A
    Basic Life Sci; 1989; 50():299-309. PubMed ID: 2665731
    [No Abstract]   [Full Text] [Related]  

  • 5. A proposed protocol for clinical trials of boron neutron capture therapy in glioblastoma multiforme.
    Dorn RV; Spickard JH; Griebenow ML
    Basic Life Sci; 1989; 50():135-44. PubMed ID: 2546532
    [No Abstract]   [Full Text] [Related]  

  • 6. Monte Carlo based protocol for cell survival and tumour control probability in BNCT.
    Ye SJ
    Phys Med Biol; 1999 Feb; 44(2):447-61. PubMed ID: 10070794
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A review of boron neutron capture therapy (BNCT) and the design and dosimetry of a high-intensity, 24 keV, neutron beam for BNCT research.
    Perks CA; Mill AJ; Constantine G; Harrison KG; Gibson JA
    Br J Radiol; 1988 Dec; 61(732):1115-26. PubMed ID: 3064858
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified boron neutron capture therapy for malignant gliomas performed using epithermal neutron and two boron compounds with different accumulation mechanisms: an efficacy study based on findings on neuroimages.
    Miyatake S; Kawabata S; Kajimoto Y; Aoki A; Yokoyama K; Yamada M; Kuroiwa T; Tsuji M; Imahori Y; Kirihata M; Sakurai Y; Masunaga S; Nagata K; Maruhashi A; Ono K
    J Neurosurg; 2005 Dec; 103(6):1000-9. PubMed ID: 16381186
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computerized axial tomographic and magnetic resonance imaging scan follow-up of two patients after boron neutron capture therapy for glioblastoma multiforme.
    Marano SR; Spickard JH; Griebenow ML
    Basic Life Sci; 1989; 50():153-63. PubMed ID: 2546533
    [No Abstract]   [Full Text] [Related]  

  • 10. Vascular factors affecting drug delivery to brain tumors.
    Tyson G; Fenstermacher J; Davis R
    Basic Life Sci; 1989; 50():115-20. PubMed ID: 2751603
    [No Abstract]   [Full Text] [Related]  

  • 11. Boron neutron capture therapy: cellular targeting of high linear energy transfer radiation.
    Coderre JA; Turcotte JC; Riley KJ; Binns PJ; Harling OK; Kiger WS
    Technol Cancer Res Treat; 2003 Oct; 2(5):355-75. PubMed ID: 14529302
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Boron neutron-capture therapy (BNCT) for glioblastoma multiforme (GBM) using the epithermal neutron beam at the Brookhaven National Laboratory.
    Chadha M; Capala J; Coderre JA; Elowitz EH; Iwai J; Joel DD; Liu HB; Wielopolski L; Chanana AD
    Int J Radiat Oncol Biol Phys; 1998 Mar; 40(4):829-34. PubMed ID: 9531367
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Neutron capture therapy for cancer].
    Fukuda H; Ichihashi M; Mishima Y
    Gan To Kagaku Ryoho; 1994 Feb; 21(3):374-8. PubMed ID: 8109994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On the optimal energy of epithermal neutron beams for BNCT.
    Biscegliet E; Colangelo P; Colonna N; Santorelli P; Variale V
    Phys Med Biol; 2000 Jan; 45(1):49-58. PubMed ID: 10661582
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combination of boron neutron capture therapy and external beam radiotherapy for brain tumors.
    Barth RF; Grecula JC; Yang W; Rotaru JH; Nawrocky M; Gupta N; Albertson BJ; Ferketich AK; Moeschberger ML; Coderre JA; Rofstad EK
    Int J Radiat Oncol Biol Phys; 2004 Jan; 58(1):267-77. PubMed ID: 14697448
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A feasibility study of a deuterium-deuterium neutron generator-based boron neutron capture therapy system for treatment of brain tumors.
    Hsieh M; Liu Y; Mostafaei F; Poulson JM; Nie LH
    Med Phys; 2017 Feb; 44(2):637-643. PubMed ID: 28205309
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A versatile, new accelerator design for boron neutron capture therapy: accelerator design and neutron energy considerations.
    Shefer RE; Klinkowstein RE; Yanch JC; Brownell GL
    Basic Life Sci; 1990; 54():259-70. PubMed ID: 2176456
    [No Abstract]   [Full Text] [Related]  

  • 18. [Possibilities of boron neutron capture therapy in the treatment of malignant brain tumors].
    Kanygin VV; Kichigin AI; Gubanova NV; Taskaev SY
    Vestn Rentgenol Radiol; 2015; (6):36-42. PubMed ID: 26999933
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The interpretation of dose calculations and cell-survival measurements for the boron neutron capture therapy of brain tumours with 24 keV neurons.
    Mill AJ; Harrison KG
    Br J Radiol; 1988 Dec; 61(732):1147-54. PubMed ID: 3219496
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Depth-dose evaluation and optimisation of the irradiation facility for boron neutron capture therapy of brain tumours.
    Matsumoto T; Aizawa O
    Phys Med Biol; 1985 Sep; 30(9):897-907. PubMed ID: 4048274
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.