161 related articles for article (PubMed ID: 27516461)
1. Survival After Rate-Responsive Programming in Patients With Cardiac Resynchronization Therapy-Defibrillator Implants Is Associated With a Novel Parameter: The Heart Rate Score.
Olshansky B; Richards M; Sharma A; Wold N; Jones P; Perschbacher D; Wilkoff BL
Circ Arrhythm Electrophysiol; 2016 Aug; 9(8):. PubMed ID: 27516461
[TBL] [Abstract][Full Text] [Related]
2. Addition of minute ventilation to rate-response pacing improves heart rate score more than accelerometer alone.
Richards M; Olshansky B; Sharma AD; Wold N; Jones P; Perschbacher D; Wilkoff BL
Heart Rhythm; 2018 Nov; 15(11):1730-1735. PubMed ID: 29908371
[TBL] [Abstract][Full Text] [Related]
3. Lower rate limit for pacing by cardiac resynchronization defibrillators: Should lower rate programming be reconsidered?
Sharma AD; Wilkoff BL; Richards M; Wold N; Jones P; Perschbacher D; Olshansky B
Heart Rhythm; 2021 Dec; 18(12):2087-2093. PubMed ID: 34371194
[TBL] [Abstract][Full Text] [Related]
4. Rate responsive pacing using cardiac resynchronization therapy in patients with chronotropic incompetence and chronic heart failure.
Sims DB; Mignatti A; Colombo PC; Uriel N; Garcia LI; Ehlert FA; Jorde UP
Europace; 2011 Oct; 13(10):1459-63. PubMed ID: 21551475
[TBL] [Abstract][Full Text] [Related]
5. Heart rate score predicts mortality independent of shocks in ICD and CRT-D patients.
Olshansky B; Richards M; Sharma AD; Jones PW; Wold N; Perschbacher D; Wilkoff BL
J Interv Card Electrophysiol; 2020 Jun; 58(1):103-111. PubMed ID: 31875270
[TBL] [Abstract][Full Text] [Related]
6. A Device Histogram-Based Simple Predictor of Mortality Risk in ICD and CRT-D Patients: The Heart Rate Score.
Wilkoff BL; Richards M; Sharma A; Wold N; Jones P; Perschbacher D; Olshansky B
Pacing Clin Electrophysiol; 2017 Apr; 40(4):333-343. PubMed ID: 28156008
[TBL] [Abstract][Full Text] [Related]
7. Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy.
Ruwald MH; Mittal S; Ruwald AC; Aktas MK; Daubert JP; McNitt S; Al-Ahmad A; Jons C; Kutyifa V; Steinberg JS; Wang P; Moss AJ; Zareba W
J Am Coll Cardiol; 2014 Sep; 64(10):971-81. PubMed ID: 25190230
[TBL] [Abstract][Full Text] [Related]
8. Applicability of a risk score for prediction of the long-term benefit of the implantable cardioverter defibrillator in patients receiving cardiac resynchronization therapy.
Barra S; Looi KL; Gajendragadkar PR; Khan FZ; Virdee M; Agarwal S
Europace; 2016 Aug; 18(8):1187-93. PubMed ID: 26566940
[TBL] [Abstract][Full Text] [Related]
9. Atrioventricular delay programming and the benefit of cardiac resynchronization therapy in MADIT-CRT.
Brenyo A; Kutyifa V; Moss AJ; Mathias A; Barsheshet A; Pouleur AC; Knappe D; McNitt S; Polonsky B; Huang DT; Solomon SD; Zareba W; Goldenberg I
Heart Rhythm; 2013 Aug; 10(8):1136-43. PubMed ID: 23712031
[TBL] [Abstract][Full Text] [Related]
10. Inverse Relationship of Blood Pressure to Long-Term Outcomes and Benefit of Cardiac Resynchronization Therapy in Patients With Mild Heart Failure: A Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy Long-Term Follow-Up Substudy.
Biton Y; Moss AJ; Kutyifa V; Mathias A; Sherazi S; Zareba W; McNitt S; Polonsky B; Barsheshet A; Brown MW; Goldenberg I
Circ Heart Fail; 2015 Sep; 8(5):921-6. PubMed ID: 26179186
[TBL] [Abstract][Full Text] [Related]
11. Pacing Evaluation-Atrial SUpport Study in Cardiac Resynchronization Therapy (PEGASUS CRT): design and rationale.
Martin DO; Stolen KQ; Brown S; Yu Y; Christie C; Doshi SK; Smith JM; Gold MR; Day JD
Am Heart J; 2007 Jan; 153(1):7-13. PubMed ID: 17174627
[TBL] [Abstract][Full Text] [Related]
12. Predictors of super-response to cardiac resynchronization therapy and associated improvement in clinical outcome: the MADIT-CRT (multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy) study.
Hsu JC; Solomon SD; Bourgoun M; McNitt S; Goldenberg I; Klein H; Moss AJ; Foster E;
J Am Coll Cardiol; 2012 Jun; 59(25):2366-73. PubMed ID: 22698490
[TBL] [Abstract][Full Text] [Related]
13. The association between biventricular pacing and cardiac resynchronization therapy-defibrillator efficacy when compared with implantable cardioverter defibrillator on outcomes and reverse remodelling.
Ruwald AC; Kutyifa V; Ruwald MH; Solomon S; Daubert JP; Jons C; Brenyo A; McNitt S; Do D; Tanabe K; Al-Ahmad A; Wang P; Moss AJ; Zareba W
Eur Heart J; 2015 Feb; 36(7):440-8. PubMed ID: 25112662
[TBL] [Abstract][Full Text] [Related]
14. [DDD versus DDDR pacemaker stimulation: comparison of cardiopulmonary performance, incidence of atrial arrhythmias and quality of life].
Epperlein S; Kreft A; Siegert V; Liebrich A; Himmrich E; Treese N
Z Kardiol; 1996 Apr; 85(4):226-36. PubMed ID: 8693765
[TBL] [Abstract][Full Text] [Related]
15. Implantable defibrillators improve survival in patients with mildly symptomatic heart failure receiving cardiac resynchronization therapy: analysis of the long-term follow-up of remodeling in systolic left ventricular dysfunction (REVERSE).
Gold MR; Daubert JC; Abraham WT; Hassager C; Dinerman JL; Hudnall JH; Cerkvenik J; Linde C
Circ Arrhythm Electrophysiol; 2013 Dec; 6(6):1163-8. PubMed ID: 24125796
[TBL] [Abstract][Full Text] [Related]
16. Initial heart rate score predicts new-onset atrial tachyarrhythmias in pacemaker patients.
Hayashi K; Abe H; Olshansky B; Sharma AD; Jones PW; Wold N; Perschbacher D; Kohno R; Richards M; Wilkoff BL
Europace; 2023 Aug; 25(9):. PubMed ID: 37552791
[TBL] [Abstract][Full Text] [Related]
17. Sex Differences in Long-Term Outcomes With Cardiac Resynchronization Therapy in Mild Heart Failure Patients With Left Bundle Branch Block.
Biton Y; Zareba W; Goldenberg I; Klein H; McNitt S; Polonsky B; Moss AJ; Kutyifa V;
J Am Heart Assoc; 2015 Jun; 4(7):. PubMed ID: 26124205
[TBL] [Abstract][Full Text] [Related]
18. Minute ventilation sensor-driven rate response as a part of cardiac resynchronization therapy optimization in older patients.
Karvonen J; Lehto S; Lenz C; Beaudoint C; Oyeniran S; Kayser T; Vikman S; Pakarinen S
J Interv Card Electrophysiol; 2024 Jun; ():. PubMed ID: 38914900
[TBL] [Abstract][Full Text] [Related]
19. A novel algorithm for individualized cardiac resynchronization therapy: rationale and design of the adaptive cardiac resynchronization therapy trial.
Krum H; Lemke B; Birnie D; Lee KL; Aonuma K; Starling RC; Gasparini M; Gorcsan J; Rogers T; Sambelashvili A; Kalmes A; Martin D
Am Heart J; 2012 May; 163(5):747-752.e1. PubMed ID: 22607850
[TBL] [Abstract][Full Text] [Related]
20. Comparative Effectiveness of Cardiac Resynchronization Therapy Among Patients With Heart Failure and Atrial Fibrillation: Findings From the National Cardiovascular Data Registry's Implantable Cardioverter-Defibrillator Registry.
Khazanie P; Greiner MA; Al-Khatib SM; Piccini JP; Turakhia MP; Varosy PD; Masoudi FA; Curtis LH; Hernandez AF;
Circ Heart Fail; 2016 Jun; 9(6):. PubMed ID: 27296396
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]