236 related articles for article (PubMed ID: 27527355)
1. Markedly different tissue types on optical coherence tomography imaging in a patient with multiple lesion drug-eluting stent in-stent restenosis.
Rheude TA; Xhepa E; Byrne RA
Catheter Cardiovasc Interv; 2017 May; 89(6):E181-E184. PubMed ID: 27527355
[TBL] [Abstract][Full Text] [Related]
2. Simple balloon dilation for drug-eluting in-stent restenosis: an optical coherent tomography analysis.
Arikawa R; Yamaguchi H; Takaoka J; Miyamura A; Atsuchi N; Ninomiya T; Atsuchi Y; Ohishi M; Terashima M; Kaneda H
Cardiovasc Revasc Med; 2015; 16(1):27-31. PubMed ID: 25578507
[TBL] [Abstract][Full Text] [Related]
3. Angiographic patterns of drug-eluting stent restenosis after treatment with drug-coated balloon versus balloon angioplasty: Late lumen loss subgroup analyses of the PEPCAD-DES study.
Rittger H; Wöhrle J; Brachmann J; Hohenforst-Schmidt W; Schlundt C; Lonke S; von Cranach M; Markovic S; Achenbach S; Waliszewski M
Catheter Cardiovasc Interv; 2016 Oct; 88(4):529-534. PubMed ID: 26893095
[TBL] [Abstract][Full Text] [Related]
4. Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation.
Tada T; Kadota K; Hosogi S; Miyake K; Ohya M; Amano H; Izawa Y; Kanazawa T; Kubo S; Ichinohe T; Hyoudou Y; Hayakawa Y; Sabbah MM; Otsuru S; Hasegawa D; Habara S; Tanaka H; Fuku Y; Katoh H; Goto T; Mitsudo K
Eur Heart J Cardiovasc Imaging; 2015 Oct; 16(10):1101-11. PubMed ID: 25762559
[TBL] [Abstract][Full Text] [Related]
5. Comparison of in-stent neoatherosclerosis and tissue characteristics between early and late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study.
Sabbah M; Kadota K; El-Eraky A; Kamal HM; Abdellah AT; El Hawary A
Int J Cardiovasc Imaging; 2017 Oct; 33(10):1463-1472. PubMed ID: 28444549
[TBL] [Abstract][Full Text] [Related]
6. Optical coherence tomography characteristics of in-stent restenosis after drug-eluting stent implantation: a novel classification and its clinical significance.
Yamamoto W; Fujii K; Otsuji S; Takiuchi S; Kakishita M; Ibuki M; Hasegawa K; Ishibuchi K; Tamaru H; Yasuda S; Ishii R; Nakabayashi S; Kusumoto H; Higashino Y
Heart Vessels; 2020 Jan; 35(1):38-45. PubMed ID: 31250131
[TBL] [Abstract][Full Text] [Related]
7. Impact of optical coherence tomography-derived neointimal tissue morphology on development of very late in-stent restenosis.
Fujii K; Otsuji S; Yamamoto W; Takiuchi S; Ishibuchi K; Tamaru H; Kakishita M; Ibuki M; Hasegawa K; Ishii R; Nakabayashi S; Higashino Y
Catheter Cardiovasc Interv; 2020 Oct; 96(4):E398-E405. PubMed ID: 32077557
[TBL] [Abstract][Full Text] [Related]
8. Association of morphologic characteristics on optical coherence tomography and angiographic progression patterns of late restenosis after drug-eluting stent implantation.
Yamaguchi H; Arikawa R; Takaoka J; Miyamura A; Atsuchi N; Ninomiya T; Atsuchi Y; Ohishi M; Terashima M; Kaneda H
Cardiovasc Revasc Med; 2015; 16(1):32-5. PubMed ID: 25617940
[TBL] [Abstract][Full Text] [Related]
9. Late Restenosis After Both First-Generation and Second-Generation Drug-Eluting Stent Implantations Occurs in Patients With Drug-Eluting Stent Restenosis.
Habara S; Kadota K; Kuwayama A; Shimada T; Ohya M; Miura K; Amano H; Kubo S; Hyodo Y; Otsuru S; Tada T; Tanaka H; Fuku Y; Goto T
Circ Cardiovasc Interv; 2016 Dec; 9(12):. PubMed ID: 27932532
[TBL] [Abstract][Full Text] [Related]
10. Comparison between drug-coated balloon angioplasty and second-generation drug-eluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation.
Kang IS; Shehata I; Shin DH; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK
Heart Vessels; 2016 Sep; 31(9):1405-11. PubMed ID: 26337620
[TBL] [Abstract][Full Text] [Related]
11. Challenging treatment of in-stent restenosis in a coronary bifurcation by implantation of a bioresorbable scaffold under optical coherence tomography guidance.
Zuk G; Ciecwierz D; Drewla P; Gruchała M; Gutiérrez-Chico JL; Jaguszewski M
Cardiol J; 2019; 26(3):304-306. PubMed ID: 31246271
[No Abstract] [Full Text] [Related]
12. Neoatherosclerosis assessed with optical coherence tomography in restenotic bare metal and first- and second-generation drug-eluting stents.
Song L; Mintz GS; Yin D; Yamamoto MH; Chin CY; Matsumura M; Fall K; Kirtane AJ; Parikh MA; Moses JW; Ali ZA; Shlofmitz RA; Maehara A
Int J Cardiovasc Imaging; 2017 Aug; 33(8):1115-1124. PubMed ID: 28281026
[TBL] [Abstract][Full Text] [Related]
13. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study.
Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W
EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717
[TBL] [Abstract][Full Text] [Related]
14. Biological effect on drug distribution and vascular healing via paclitaxel-coated balloon technology in drug eluting stent restenosis swine model.
Li Y; Tellez A; Rousselle SD; Dillon KN; Garza JA; Barry C; Granada JF
Catheter Cardiovasc Interv; 2016 Jul; 88(1):89-98. PubMed ID: 26613810
[TBL] [Abstract][Full Text] [Related]
15. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.
Wang G; Sun Z; Jin Q; Xu K; Li Y; Wang X; Ma Y; Liu H; Zhao X; Wang B; Deng J; Guan S; Ge M; Wang X; Xu B; Han Y
Catheter Cardiovasc Interv; 2015 Mar; 85 Suppl 1():744-51. PubMed ID: 25630447
[TBL] [Abstract][Full Text] [Related]
16. Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy.
Martí D; López E; Álvarez S; Palazuelos J; Rada I; Alfonso F
Cardiovasc Revasc Med; 2016 Dec; 17(8):584-585. PubMed ID: 27743816
[TBL] [Abstract][Full Text] [Related]
17. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
[TBL] [Abstract][Full Text] [Related]
18. Paclitaxel-coated balloon for the treatment of drug-eluting stent restenosis: subanalysis results from the Valentines I trial.
Loh JP; Stella PR; Sangiorgi G; Silber S; Stahnke S; von Strandmann RP; Torguson R; Waksman R
Cardiovasc Revasc Med; 2014 Jan; 15(1):23-8. PubMed ID: 24444473
[TBL] [Abstract][Full Text] [Related]
19. Very early in-stent neoatherosclerosis assessed by optical coherence tomography.
Vergara-Martel A; Pizzato PE; Dallan LAP; Pereira GTR; Richmond HCT; Attizzani GF; Jones MR
Int J Cardiovasc Imaging; 2019 Oct; 35(10):1793-1794. PubMed ID: 31175526
[No Abstract] [Full Text] [Related]
20. Two-year results and subgroup analyses of the PEPCAD China in-stent restenosis trial: A prospective, multicenter, randomized trial for the treatment of drug-eluting stent in-stent restenosis.
Xu B; Qian J; Ge J; Wang J; Chen F; Chen J; Wei M; Chen Y; Yang Y; Gao R;
Catheter Cardiovasc Interv; 2016 Mar; 87 Suppl 1():624-9. PubMed ID: 26775079
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]