170 related articles for article (PubMed ID: 27534824)
1. A lab-on-a-disc with reversible and thermally stable diaphragm valves. Kim TH; Sunkara V; Park J; Kim CJ; Woo HK; Cho YK Lab Chip; 2016 Oct; 16(19):3741-9. PubMed ID: 27534824 [TBL] [Abstract][Full Text] [Related]
2. Low-High-Low Rotationally Pulse-Actuated Serial Dissolvable Film Valves Applied to Solid Phase Extraction and LAMP Isothermal Amplification for Plant Pathogen Detection on a Lab-on-a-Disc. Julius LA; Saeed MM; Kuijpers T; Sandu S; Henihan G; Dreo T; Schoen CD; Mishra R; Dunne NJ; Carthy E; Ducrée J; Kinahan DJ ACS Omega; 2024 Jan; 9(3):3262-3275. PubMed ID: 38284094 [TBL] [Abstract][Full Text] [Related]
3. Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves. Mishra R; Julius LA; Condon J; Pavelskopfa P; Early PL; Dorrian M; Mrvova K; Henihan G; Mangwanya F; Dreo T; Ducrée J; Macdonald NP; Schoen C; Kinahan DJ Anal Chim Acta; 2023 Jun; 1258():341070. PubMed ID: 37087288 [TBL] [Abstract][Full Text] [Related]
4. Wirelessly powered and remotely controlled valve-array for highly multiplexed analytical assay automation on a centrifugal microfluidic platform. Torres Delgado SM; Kinahan DJ; Nirupa Julius LA; Mallette A; Ardila DS; Mishra R; Miyazaki CM; Korvink JG; Ducrée J; Mager D Biosens Bioelectron; 2018 Jun; 109():214-223. PubMed ID: 29567566 [TBL] [Abstract][Full Text] [Related]
5. Microvalves for Applications in Centrifugal Microfluidics. Peshin S; Madou M; Kulinsky L Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433550 [TBL] [Abstract][Full Text] [Related]
6. Automated solid phase DNA extraction on a lab-on-a-disc with two-degrees of freedom instrumentation. Carthy É; Hughes B; Higgins E; Early P; Merne C; Walsh D; Parle-McDermott A; Kinahan DJ Anal Chim Acta; 2023 Nov; 1280():341859. PubMed ID: 37858565 [TBL] [Abstract][Full Text] [Related]
7. From cellular lysis to microarray detection, an integrated thermoplastic elastomer (TPE) point of care Lab on a Disc. Roy E; Stewart G; Mounier M; Malic L; Peytavi R; Clime L; Madou M; Bossinot M; Bergeron MG; Veres T Lab Chip; 2015 Jan; 15(2):406-16. PubMed ID: 25385141 [TBL] [Abstract][Full Text] [Related]
11. PMMA/PDMS valves and pumps for disposable microfluidics. Zhang W; Lin S; Wang C; Hu J; Li C; Zhuang Z; Zhou Y; Mathies RA; Yang CJ Lab Chip; 2009 Nov; 9(21):3088-94. PubMed ID: 19823724 [TBL] [Abstract][Full Text] [Related]
12. Capillary Flow-Driven and Magnetically Actuated Multi-Use Wax Valves for Controlled Sealing and Releasing of Fluids on Centrifugal Microfluidic Platforms. Peshin S; George D; Shiri R; Kulinsky L; Madou M Micromachines (Basel); 2022 Feb; 13(2):. PubMed ID: 35208427 [TBL] [Abstract][Full Text] [Related]
13. Autonomous lab-on-a-chip generic architecture for disposables with integrated actuation. Suska A; Filippini D Sci Rep; 2019 Dec; 9(1):20320. PubMed ID: 31889049 [TBL] [Abstract][Full Text] [Related]
14. A paper-based microfluidic platform with shape-memory-polymer-actuated fluid valves for automated multi-step immunoassays. Fu H; Song P; Wu Q; Zhao C; Pan P; Li X; Li-Jessen NYK; Liu X Microsyst Nanoeng; 2019; 5():50. PubMed ID: 31636936 [TBL] [Abstract][Full Text] [Related]
15. Monolithic Teflon membrane valves and pumps for harsh chemical and low-temperature use. Willis PA; Hunt BD; White VE; Lee MC; Ikeda M; Bae S; Pelletier MJ; Grunthaner FJ Lab Chip; 2007 Nov; 7(11):1469-74. PubMed ID: 17960273 [TBL] [Abstract][Full Text] [Related]
16. Power-free chip enzyme immunoassay for detection of prostate specific antigen (PSA) in serum. Adel Ahmed H; Azzazy HM Biosens Bioelectron; 2013 Nov; 49():478-84. PubMed ID: 23811482 [TBL] [Abstract][Full Text] [Related]
17. A novel electromagnet-triggered pillar valve and its application in immunoassay on a centrifugal platform. Chen Y; Shen M; Zhu Y; Xu Y Lab Chip; 2019 May; 19(10):1728-1735. PubMed ID: 31020298 [TBL] [Abstract][Full Text] [Related]
18. A versatile valving toolkit for automating fluidic operations in paper microfluidic devices. Toley BJ; Wang JA; Gupta M; Buser JR; Lafleur LK; Lutz BR; Fu E; Yager P Lab Chip; 2015 Mar; 15(6):1432-44. PubMed ID: 25606810 [TBL] [Abstract][Full Text] [Related]
19. Robust temperature change rate actuated valving and switching for highly integrated centrifugal microfluidics. Keller M; Czilwik G; Schott J; Schwarz I; Dormanns K; von Stetten F; Zengerle R; Paust N Lab Chip; 2017 Feb; 17(5):864-875. PubMed ID: 28181607 [TBL] [Abstract][Full Text] [Related]
20. Digital process control of multi-step assays on centrifugal platforms using high-low-high rotational-pulse triggered valving. Early PL; Kilcawley NA; McArdle NA; Renou M; Kearney SM; Mishra R; Dimov N; Glynn MT; Ducrée J; Kinahan DJ PLoS One; 2023; 18(9):e0291165. PubMed ID: 37682949 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]