These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
265 related articles for article (PubMed ID: 27534971)
1. Combined PET/MRI: from Status Quo to Status Go. Summary Report of the Fifth International Workshop on PET/MR Imaging; February 15-19, 2016; Tübingen, Germany. Bailey DL; Pichler BJ; Gückel B; Barthel H; Beer AJ; Botnar R; Gillies R; Goh V; Gotthardt M; Hicks RJ; Lanzenberger R; la Fougere C; Lentschig M; Nekolla SG; Niederdraenk T; Nikolaou K; Nuyts J; Olego D; Riklund KÅ; Signore A; Schäfers M; Sossi V; Suminski M; Veit-Haibach P; Umutlu L; Wissmeyer M; Beyer T Mol Imaging Biol; 2016 Oct; 18(5):637-50. PubMed ID: 27534971 [TBL] [Abstract][Full Text] [Related]
2. Combined PET/MRI: Multi-modality Multi-parametric Imaging Is Here: Summary Report of the 4th International Workshop on PET/MR Imaging; February 23-27, 2015, Tübingen, Germany. Bailey DL; Pichler BJ; Gückel B; Barthel H; Beer AJ; Bremerich J; Czernin J; Drzezga A; Franzius C; Goh V; Hartenbach M; Iida H; Kjaer A; la Fougère C; Ladefoged CN; Law I; Nikolaou K; Quick HH; Sabri O; Schäfer J; Schäfers M; Wehrl HF; Beyer T Mol Imaging Biol; 2015 Oct; 17(5):595-608. PubMed ID: 26286794 [TBL] [Abstract][Full Text] [Related]
3. Combined PET/MR: The Real Work Has Just Started. Summary Report of the Third International Workshop on PET/MR Imaging; February 17-21, 2014, Tübingen, Germany. Bailey DL; Antoch G; Bartenstein P; Barthel H; Beer AJ; Bisdas S; Bluemke DA; Boellaard R; Claussen CD; Franzius C; Hacker M; Hricak H; la Fougère C; Gückel B; Nekolla SG; Pichler BJ; Purz S; Quick HH; Sabri O; Sattler B; Schäfer J; Schmidt H; van den Hoff J; Voss S; Weber W; Wehrl HF; Beyer T Mol Imaging Biol; 2015 Jun; 17(3):297-312. PubMed ID: 25672749 [TBL] [Abstract][Full Text] [Related]
4. Combined PET/MRI: Global Warming-Summary Report of the 6th International Workshop on PET/MRI, March 27-29, 2017, Tübingen, Germany. Bailey DL; Pichler BJ; Gückel B; Antoch G; Barthel H; Bhujwalla ZM; Biskup S; Biswal S; Bitzer M; Boellaard R; Braren RF; Brendle C; Brindle K; Chiti A; la Fougère C; Gillies R; Goh V; Goyen M; Hacker M; Heukamp L; Knudsen GM; Krackhardt AM; Law I; Morris JC; Nikolaou K; Nuyts J; Ordonez AA; Pantel K; Quick HH; Riklund K; Sabri O; Sattler B; Troost EGC; Zaiss M; Zender L; Beyer T Mol Imaging Biol; 2018 Feb; 20(1):4-20. PubMed ID: 28971346 [TBL] [Abstract][Full Text] [Related]
5. Combined PET/MR: Where are we now? Summary report of the second international workshop on PET/MR imaging April 8-12, 2013, Tubingen, Germany. Bailey DL; Barthel H; Beuthin-Baumann B; Beyer T; Bisdas S; Boellaard R; Czernin J; Drzezga A; Ernemann U; Franzius C; Gückel B; Handgretinger R; Hartenbach M; Hellwig D; Nadel H; Nekolla SG; Pfluger T; Pichler BJ; Quick HH; Sabri O; Sattler B; Schäfer J; Schick F; Siegel BA; Schlemmer HP; Schwenzer NF; van den Hoff J; Veit-Haibach P; Wehrl HF Mol Imaging Biol; 2014 Jun; 16(3):295-310. PubMed ID: 24668195 [TBL] [Abstract][Full Text] [Related]
6. Summary report of the First International Workshop on PET/MR imaging, March 19-23, 2012, Tübingen, Germany. Bailey DL; Barthel H; Beyer T; Boellaard R; Gückel B; Hellwig D; Herzog H; Pichler BJ; Quick HH; Sabri O; Scheffler K; Schlemmer HP; Schwenzer NF; Wehrl HF Mol Imaging Biol; 2013 Aug; 15(4):361-71. PubMed ID: 23515982 [TBL] [Abstract][Full Text] [Related]
7. Variations in PET/MRI Operations: Results from an International Survey Among 39 Active Sites. Fendler WP; Czernin J; Herrmann K; Beyer T J Nucl Med; 2016 Dec; 57(12):2016-2021. PubMed ID: 27516448 [TBL] [Abstract][Full Text] [Related]
8. From PET/CT to PET/MRI: advances in instrumentation and clinical applications. Hu Z; Yang W; Liu H; Wang K; Bao C; Song T; Wang J; Tian J Mol Pharm; 2014 Nov; 11(11):3798-809. PubMed ID: 25058336 [TBL] [Abstract][Full Text] [Related]
9. MR-based truncation and attenuation correction in integrated PET/MR hybrid imaging using HUGE with continuous table motion. Lindemann ME; Oehmigen M; Blumhagen JO; Gratz M; Quick HH Med Phys; 2017 Sep; 44(9):4559-4572. PubMed ID: 28675598 [TBL] [Abstract][Full Text] [Related]
10. Hybrid PET-MRI Applications in Movement Disorders. Tondo G; Esposito M; Dervenoulas G; Wilson H; Politis M; Pagano G Int Rev Neurobiol; 2019; 144():211-257. PubMed ID: 30638455 [TBL] [Abstract][Full Text] [Related]
11. Comprehensive Oncologic Imaging in Infants and Preschool Children With Substantially Reduced Radiation Exposure Using Combined Simultaneous ¹⁸F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance Imaging: A Direct Comparison to ¹⁸F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography. Gatidis S; Schmidt H; Gücke B; Bezrukov I; Seitz G; Ebinger M; Reimold M; Pfannenberg CA; Nikolaou K; Schwenzer NF; Schäfer JF Invest Radiol; 2016 Jan; 51(1):7-14. PubMed ID: 26309185 [TBL] [Abstract][Full Text] [Related]
12. Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging. Grueneisen J; Nagarajah J; Buchbender C; Hoffmann O; Schaarschmidt BM; Poeppel T; Forsting M; Quick HH; Umutlu L; Kinner S Invest Radiol; 2015 Aug; 50(8):505-13. PubMed ID: 26115367 [TBL] [Abstract][Full Text] [Related]
13. Whole-body PET/MRI: the effect of bone attenuation during MR-based attenuation correction in oncology imaging. Aznar MC; Sersar R; Saabye J; Ladefoged CN; Andersen FL; Rasmussen JH; Löfgren J; Beyer T Eur J Radiol; 2014 Jul; 83(7):1177-1183. PubMed ID: 24780817 [TBL] [Abstract][Full Text] [Related]
14. Hybrid Positron Emission Tomography/Magnetic Resonance Imaging: Challenges, Methods, and State of the Art of Hardware Component Attenuation Correction. Paulus DH; Quick HH Invest Radiol; 2016 Oct; 51(10):624-34. PubMed ID: 27175550 [TBL] [Abstract][Full Text] [Related]