253 related articles for article (PubMed ID: 27538708)
21. Widening of the safe trajectory range during subaxial cervical pedicle screw placement: advantages of a curved pedicle probe and laterally located starting point without creating a funnel-shaped hole.
Lee S; Seo J; Lee MK; Jeon SR; Roh SW; Rhim SC; Park JH
J Neurosurg Spine; 2017 Aug; 27(2):150-157. PubMed ID: 28524752
[TBL] [Abstract][Full Text] [Related]
22. The medial cortical pedicle screw--a new technique for cervical pedicle screw placement with partial drilling of medial cortex.
Mahesh B; Upendra B; Mahan RS
Spine J; 2014 Feb; 14(2):371-80. PubMed ID: 24444420
[TBL] [Abstract][Full Text] [Related]
23. A New Entrance Technique for C2 Pedicle Screw Placement and the Use in Patients With Atlantoaxial Instability.
Liu JM; Jiang J; Liu ZL; Long XH; Chen WZ; Zhou Y; Gao S; He LC; Huang SH
Clin Spine Surg; 2017 Jun; 30(5):E573-E577. PubMed ID: 28525480
[TBL] [Abstract][Full Text] [Related]
24. Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine.
Zhao L; Li G; Liu J; Benedict GM; Ebraheim NA; Ma W; Sun S; Xu R; Ruan C
Eur Spine J; 2014 Oct; 23(10):2175-81. PubMed ID: 25056398
[TBL] [Abstract][Full Text] [Related]
25. The accuracy of a novel pedicle screw insertion technique assisted by a special angular scale in the subaxial cervical spine using lateral mass as a reference marker.
Shi H; Zhu L; Ma J; Zhu YC; Wu XT
J Orthop Surg Res; 2020 Nov; 15(1):551. PubMed ID: 33228707
[TBL] [Abstract][Full Text] [Related]
26. Optimal screw positioning in cervical pedicles to avoid complications.
Atalar K; Coşkun ZK; Kaymaz AM
Turk J Med Sci; 2022 Aug; 52(4):1118-1129. PubMed ID: 36326362
[TBL] [Abstract][Full Text] [Related]
27. Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology.
Theologis AA; Burch S
Spine (Phila Pa 1976); 2015 Sep; 40(18):1397-406. PubMed ID: 26426710
[TBL] [Abstract][Full Text] [Related]
28. Application of a novel 3D drill template for cervical pedicle screw tunnel design: a cadaveric study.
Yu Z; Zhang G; Chen X; Chen X; Wu C; Lin Y; Huang W; Lin H
Eur Spine J; 2017 Sep; 26(9):2348-2356. PubMed ID: 28601990
[TBL] [Abstract][Full Text] [Related]
29. Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.
Sakamoto T; Neo M; Nakamura T
Spine (Phila Pa 1976); 2004 Nov; 29(22):2510-4; discussion 2515. PubMed ID: 15543062
[TBL] [Abstract][Full Text] [Related]
30. Comparison of Morphometric Measurements of Traditional Posterior Cervical Screw and Paravertebral Foramen Screw in Chinese Population.
Chen X; Yang Q; Kalisi KUMM; Yuan S; Tian Y; Liu X
Spine (Phila Pa 1976); 2021 Apr; 46(7):E443-E449. PubMed ID: 33181767
[TBL] [Abstract][Full Text] [Related]
31. Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae.
Lee DH; Lee SW; Kang SJ; Hwang CJ; Kim NH; Bae JY; Kim YT; Lee CS; Daniel Riew K
Eur Spine J; 2011 Jun; 20(6):905-11. PubMed ID: 21475996
[TBL] [Abstract][Full Text] [Related]
32. Does Navigation Improve Pedicle Screw Placement Accuracy? Comparison Between Navigated and Non-navigated Percutaneous and Open Fixations.
Innocenzi G; Bistazzoni S; D'Ercole M; Cardarelli G; Ricciardi F
Acta Neurochir Suppl; 2017; 124():289-295. PubMed ID: 28120086
[TBL] [Abstract][Full Text] [Related]
33. Minimally invasive guidewireless, navigated pedicle screw placement: a technical report and case series.
Smith BW; Joseph JR; Kirsch M; Strasser MO; Smith J; Park P
Neurosurg Focus; 2017 Aug; 43(2):E9. PubMed ID: 28760033
[TBL] [Abstract][Full Text] [Related]
34. Percutaneous Pedicle Screw Fixation Technique in the Thoracic and Lumbar Spine-Tips and Tricks.
Gazzeri R
Surg Technol Int; 2016 Apr; 28():303-10. PubMed ID: 27121407
[TBL] [Abstract][Full Text] [Related]
35. Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique.
Desai S; Sethi A; Ninh CC; Bartol S; Vaidya R
Eur Spine J; 2010 Nov; 19(11):1953-9. PubMed ID: 20640455
[TBL] [Abstract][Full Text] [Related]
36. Anatomic study of individualized and improved pedicle screw implantation in the lower cervical spine.
Liu Y; Zhang B; Dai M; Xiong HC; Gao S; Li BH; Yao HQ; Cao K; Liu ZL
Int Surg; 2015 Feb; 100(2):328-33. PubMed ID: 25692438
[TBL] [Abstract][Full Text] [Related]
37. A novel screw guiding method with a screw guide template system for posterior C-2 fixation: clinical article.
Kaneyama S; Sugawara T; Sumi M; Higashiyama N; Takabatake M; Mizoi K
J Neurosurg Spine; 2014 Aug; 21(2):231-8. PubMed ID: 24785974
[TBL] [Abstract][Full Text] [Related]
38. [Feasibility of a novel type of complex anterior cervical fixation by using Mimics software].
Hou ZP; Ye SQ; Zhang JH; Zhao LJ; Gu YJ; Yu L
Zhongguo Gu Shang; 2024 Jan; 37(1):81-5. PubMed ID: 38286456
[TBL] [Abstract][Full Text] [Related]
39. Coronal Multiplane Reconstructed Computed Tomography Image Determining Lateral Vertebral Notch-Referred Pedicle Screw Entry Point in Subaxial Cervical Spine: A Preclinical Study.
Wu C; Huang Z; Pan Z; Luo J; Li Z; Zhong J; Chen Y; Han Z; Abumi K; Ha Y; Cao K
World Neurosurg; 2017 Jul; 103():322-329. PubMed ID: 28434954
[TBL] [Abstract][Full Text] [Related]
40. [Accuracy of related parameters to screw placement in lower cervical pedicle measured by spinal virtual surgery system].
Cao J; He F; Li C; Liang Q; Li Z; Jiang Z
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Mar; 25(3):316-22. PubMed ID: 21500585
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]