These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 27542821)

  • 21. Unmeasured anions in critically ill patients: can they predict mortality?
    Rocktaeschel J; Morimatsu H; Uchino S; Bellomo R
    Crit Care Med; 2003 Aug; 31(8):2131-6. PubMed ID: 12973170
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Blood gas and acid-base analysis of arterial blood in 57 newborn calves.
    Bleul U; Lejeune B; Schwantag S; Kähn W
    Vet Rec; 2007 Nov; 161(20):688-91. PubMed ID: 18024924
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of complete blood counts in samples obtained from healthy dogs and cats by use of standard and microsample blood collection tubes.
    Whittemore JC; Flatland B
    J Am Vet Med Assoc; 2010 Aug; 237(3):281-7. PubMed ID: 20673108
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Unmeasured anions identified by the Fencl-Stewart method predict mortality better than base excess, anion gap, and lactate in patients in the pediatric intensive care unit.
    Balasubramanyan N; Havens PL; Hoffman GM
    Crit Care Med; 1999 Aug; 27(8):1577-81. PubMed ID: 10470767
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Venous blood gases, pH and bicarbonate values in oestrus-synchronised cows.
    Taşal I; Ceylan E; Keleş I; Gülyüz F
    Vet Rec; 2005 Jan; 156(2):50-2. PubMed ID: 15675525
    [No Abstract]   [Full Text] [Related]  

  • 26. Influence of spurious hemolysis on blood gas analysis.
    Lippi G; Fontana R; Avanzini P; Sandei F; Ippolito L
    Clin Chem Lab Med; 2013 Aug; 51(8):1651-4. PubMed ID: 23314547
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparison of syringes to collect blood for analysis of gases, electrolytes and glucose.
    Carter BG; Tibballs J; Hochmann M; Osborne A; Chiriano A; Murray G
    Anaesth Intensive Care; 1994 Dec; 22(6):698-702. PubMed ID: 7892975
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Seasonal and maternal effects on acid-base, l-lactate, electrolyte, and hematological status of 205 dairy calves born to eutocic dams.
    Kovács L; Kézér FL; Albert E; Ruff F; Szenci O
    J Dairy Sci; 2017 Sep; 100(9):7534-7543. PubMed ID: 28711257
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparison of venous blood gas analysis with paired specimens collected in syringes and evacuated blood collection tubes.
    Tang NY; Leanse JH; Tesic V; van Wijk XMR
    Clin Chim Acta; 2020 Nov; 510():671-674. PubMed ID: 32818493
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Measured and calculated variables of global oxygenation in healthy neonatal foals.
    Wong DM; Hepworth-Warren KL; Sponseller BT; Howard JM; Wang C
    Am J Vet Res; 2017 Feb; 78(2):230-238. PubMed ID: 28140639
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of a hand-held blood gas analyzer for rapid determination of blood gases, electrolytes and metabolites in intensive care setting.
    Luukkonen AA; Lehto TM; Hedberg PS; Vaskivuo TE
    Clin Chem Lab Med; 2016 Apr; 54(4):585-94. PubMed ID: 26457784
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of two portable clinical analyzers to one stationary analyzer for the determination of blood gas partial pressures and blood electrolyte concentrations in horses.
    Kirsch K; Detilleux J; Serteyn D; Sandersen C
    PLoS One; 2019; 14(2):e0211104. PubMed ID: 30768603
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses.
    Jousi M; Saikko S; Nurmi J
    Scand J Trauma Resusc Emerg Med; 2017 Sep; 25(1):92. PubMed ID: 28893316
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer.
    Uyanik M; Sertoglu E; Kayadibi H; Tapan S; Serdar MA; Bilgi C; Kurt I
    Scand J Clin Lab Invest; 2015 Apr; 75(2):97-105. PubMed ID: 25431133
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Changes in arterial, mixed venous and intraerythrocytic concentrations of ions in supramaximally exercising horses.
    Bayly WM; Kingston JK; Brown JA; Keegan RD; Greene SA; Sides RH
    Equine Vet J Suppl; 2006 Aug; (36):294-7. PubMed ID: 17402435
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Reference intervals and age and gender dependency for arterial blood gases and electrolytes in adults.
    Klæstrup E; Trydal T; Pedersen JF; Larsen JM; Lundbye-Christensen S; Kristensen SR
    Clin Chem Lab Med; 2011 Sep; 49(9):1495-500. PubMed ID: 21619466
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Venous blood gas and lactate values in adult giraffe trained for voluntary jugular phlebotomy.
    Cole JE; Dadone L; Rao S; Bapodra-Villaverde P; Schilz A; Johnston M
    Zoo Biol; 2024; 43(4):371-375. PubMed ID: 38566545
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of syringe type and storage temperature on results of blood gas analysis in arterial blood of horses.
    Picandet V; Jeanneret S; Lavoie JP
    J Vet Intern Med; 2007; 21(3):476-81. PubMed ID: 17552454
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparison of simultaneously collected arterial, mixed venous, jugular venous and cephalic venous blood samples in the assessment of blood-gas and acid-base status in the dog.
    Ilkiw JE; Rose RJ; Martin IC
    J Vet Intern Med; 1991; 5(5):294-8. PubMed ID: 1748981
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of Enterprise Point-of-Care and Nova Biomedical Critical Care Xpress analyzers for determination of arterial pH, blood gas, and electrolyte values in canine and equine blood.
    Elmeshreghi TN; Grubb TL; Greene SA; Ragle CA; Wardrop JA
    Vet Clin Pathol; 2018 Sep; 47(3):415-424. PubMed ID: 29989207
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.