156 related articles for article (PubMed ID: 27552123)
1. Estimating thickness of the inner dead-layer of n-type HPGe detector.
Chuong HD; Thanh TT; Ngoc Trang le T; Nguyen VH; Tao CV
Appl Radiat Isot; 2016 Oct; 116():174-7. PubMed ID: 27552123
[TBL] [Abstract][Full Text] [Related]
2. Dead layer estimation of an HPGe detector using MCNP6 and Geant4.
Lee H; Sung SH; Shin SH; Kim HR
Appl Radiat Isot; 2023 Feb; 192():110597. PubMed ID: 36508955
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo analysis of the influence of germanium dead layer thickness on the HPGe gamma detector experimental efficiency measured by use of extended sources.
Chham E; García FP; El Bardouni T; Ferro-García MA; Azahra M; Benaalilou K; Krikiz M; Elyaakoubi H; El Bakkali J; Kaddour M
Appl Radiat Isot; 2015 Jan; 95():30-35. PubMed ID: 25464173
[TBL] [Abstract][Full Text] [Related]
4. Monte Carlo simulation of the full energy peak efficiency of an HPGe detector.
Khan W; Zhang Q; He C; Saleh M
Appl Radiat Isot; 2018 Jan; 131():67-70. PubMed ID: 29173810
[TBL] [Abstract][Full Text] [Related]
5. MODELING AND OPTIMIZATION OF HPGE DETECTOR GC0518 USING MCNP5 CODE.
Stríbrnský B; Hinca R; Farkas G; Petriska M; Slugeň V
Radiat Prot Dosimetry; 2022 Aug; 198(9-11):704-711. PubMed ID: 36005998
[TBL] [Abstract][Full Text] [Related]
6. Experimental HPGe coaxial detector response and efficiency compared to Monte Carlo simulations.
Maidana NL; Vanin VR; García-Alvarez JA; Hermida-López M; Brualla L
Appl Radiat Isot; 2016 Feb; 108():64-74. PubMed ID: 26704703
[TBL] [Abstract][Full Text] [Related]
7. A novel method to estimate the dead layer of HPGe detector for Monte Carlo FEPE computation.
Satti KH; Siddique MT; Dilband M; Rehman SU; Mansoor S; Malik AH
Appl Radiat Isot; 2023 Dec; 202():111067. PubMed ID: 37857176
[TBL] [Abstract][Full Text] [Related]
8. Determination of detection efficiency on HPGe detector for point-like and volumetric samples based on Geant4 simulations.
Lin M; Wang Y; Qin Z
Appl Radiat Isot; 2023 Oct; 200():110989. PubMed ID: 37611498
[TBL] [Abstract][Full Text] [Related]
9. Re-construction of a HPGe detector precise modeling for efficiency calibration.
Zhang C; Hu G; Zeng J; Xiang Q; Guo X; Gong J
Appl Radiat Isot; 2022 Feb; 180():110059. PubMed ID: 34929611
[TBL] [Abstract][Full Text] [Related]
10. Verification of physical parameters of insity p-type HPGe detector by scan method using collimated low energy photon beam and MNCP simulation.
Ba VN; Giang LTH; Thien BN; Hong Loan TT; Huy NQ
Appl Radiat Isot; 2020 Sep; 163():109229. PubMed ID: 32561062
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo calculations of the HPGe detector efficiency for radioactivity measurement of large volume environmental samples.
Azbouche A; Belgaid M; Mazrou H
J Environ Radioact; 2015 Aug; 146():119-24. PubMed ID: 25982445
[TBL] [Abstract][Full Text] [Related]
12. Performance revaluation of a N-type coaxial HPGe detector with front edges crystal using MCNPX.
Azli T; Chaoui ZE
Appl Radiat Isot; 2015 Mar; 97():106-112. PubMed ID: 25569199
[TBL] [Abstract][Full Text] [Related]
13. Gamma-ray efficiency of a HPGe detector as a function of energy and geometry.
Challan MB
Appl Radiat Isot; 2013 Dec; 82():166-9. PubMed ID: 24007787
[TBL] [Abstract][Full Text] [Related]
14. Using standard calibrated geometries to characterize a coaxial high purity germanium gamma detector for Monte Carlo simulations.
van der Graaf ER; Dendooven P; Brandenburg S
Rev Sci Instrum; 2014 Jun; 85(6):065110. PubMed ID: 24985855
[TBL] [Abstract][Full Text] [Related]
15. Study of the response of an ORTEC GMX45 HPGe detector with a multi-radionuclide volume source using Monte Carlo simulations.
Saraiva A; Oliveira C; Reis M; Portugal L; Paiva I; Cruz C
Appl Radiat Isot; 2016 Jul; 113():47-52. PubMed ID: 27131096
[TBL] [Abstract][Full Text] [Related]
16. Dead layer thickness characterization of an HPGe detector by measurements and Monte Carlo simulations.
Elanique A; Marzocchi O; Leone D; Hegenbart L; Breustedt B; Oufni L
Appl Radiat Isot; 2012 Mar; 70(3):538-42. PubMed ID: 22115878
[TBL] [Abstract][Full Text] [Related]
17. Characterizing the coaxial HPGe detector using Monte Carlo simulations and evolutionary algorithms.
Prozorova IV; Ghal-Eh N; Bedenko SV; Popov YA; Prozorov AA; Vega-Carrillo HR
Appl Radiat Isot; 2021 Aug; 174():109748. PubMed ID: 33957481
[TBL] [Abstract][Full Text] [Related]
18. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.
Chagren S; Tekaya MB; Reguigui N; Gharbi F
Appl Radiat Isot; 2016 Jan; 107():359-365. PubMed ID: 26623928
[TBL] [Abstract][Full Text] [Related]
19. Corrections of HPGe detector efficiency curve due to true coincidence summing by program EFFTRAN and by Monte Carlo simulations.
Knezevic J; Mrdja D; Hansman J; Bikit K; Forkapic S; Bikit I; Velimirovic D; Kuzmanovic P
Appl Radiat Isot; 2022 Nov; 189():110421. PubMed ID: 36037728
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo based geometrical model for efficiency calculation of an n-type HPGe detector.
Cabal FP; Lopez-Pino N; Bernal-Castillo JL; Martinez-Palenzuela Y; Aguilar-Mena J; D'Alessandro K; Arbelo Y; Corrales Y; Diaz O
Appl Radiat Isot; 2010 Dec; 68(12):2403-8. PubMed ID: 20643556
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]