These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 27560678)

  • 1. In Vitro Assessment of Primary Stability of BoneTrust Sinus Implant Design.
    Gülses A; Ayna M; Güçlü H; Sencimen M; Basiry MN; Gierloff M; Açil Y
    Int J Periodontics Restorative Dent; 2016; 36(5):731-5. PubMed ID: 27560678
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Primary implant stability in the atrophic sinus floor of human cadaver maxillae: impact of residual ridge height, bone density, and implant diameter.
    Pommer B; Hof M; Fädler A; Gahleitner A; Watzek G; Watzak G
    Clin Oral Implants Res; 2014 Feb; 25(2):e109-13. PubMed ID: 23167282
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of Dental Implant Stability in Areas Previously Submitted to Maxillary Sinus Elevation.
    Silva KC; Zenóbio EG; Souza PEA; Soares RV; Cosso MG; Horta MCR
    J Oral Implantol; 2018 Apr; 44(2):109-113. PubMed ID: 29303412
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Does Length, Diameter, or Bone Quality Affect Primary and Secondary Stability in Self-Tapping Dental Implants?
    Gómez-Polo M; Ortega R; Gómez-Polo C; Martín C; Celemín A; Del Río J
    J Oral Maxillofac Surg; 2016 Jul; 74(7):1344-53. PubMed ID: 27070843
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Resonance frequency analysis of implants placed with osteotome sinus floor elevation in posterior maxillae.
    Qian SJ; Gu YX; Mo JJ; Qiao SC; Zhuang LF; Lai HC
    Clin Oral Implants Res; 2016 Jan; 27(1):113-9. PubMed ID: 25521163
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro comparison of resonance frequency analysis devices to evaluate implant stability of narrow diameter implants at varying drilling speeds in dense artificial bone blocks.
    Romanos GE; Bastardi DJ; Kakar A; Moore R; Delgado-Ruiz RA; Javed F
    Clin Implant Dent Relat Res; 2019 Oct; 21(5):1023-1027. PubMed ID: 31464362
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: II. Implant surface modifications and implant diameter.
    Han J; Lulic M; Lang NP
    Clin Oral Implants Res; 2010 Jun; 21(6):605-11. PubMed ID: 20666787
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.
    Romanos GE; Basha-Hijazi A; Gupta B; Ren YF; Malmstrom H
    Clin Implant Dent Relat Res; 2014 Apr; 16(2):166-71. PubMed ID: 22726877
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stability evaluation of implants integrated in grafted and nongrafted maxillary bone: a clinical study from implant placement to abutment connection.
    Rasmusson L; Thor A; Sennerby L
    Clin Implant Dent Relat Res; 2012 Mar; 14(1):61-6. PubMed ID: 20491814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dental implant stability is influenced by implant diameter and localization and by the use of plasma rich in growth factors.
    Quesada-García MP; Prados-Sánchez E; Olmedo-Gaya MV; Muñoz-Soto E; Vallecillo-Capilla M; Bravo M
    J Oral Maxillofac Surg; 2012 Dec; 70(12):2761-7. PubMed ID: 23010369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants.
    Sul YT; Jönsson J; Yoon GS; Johansson C
    Clin Oral Implants Res; 2009 Oct; 20(10):1146-55. PubMed ID: 19719742
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Resonance frequency analysis of stability on ITI implants with osteotome sinus floor elevation technique without grafting: a 5-month prospective study.
    Lai HC; Zhang ZY; Wang F; Zhuang LF; Liu X
    Clin Oral Implants Res; 2008 May; 19(5):469-75. PubMed ID: 18371099
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implant restoration 3 months after one stage sinus lift surgery in severely resorbed maxillae: 2-year results of a multicenter prospective clinical study.
    Canullo L; Patacchia O; Sisti A; Heinemann F
    Clin Implant Dent Relat Res; 2012 Jun; 14(3):412-20. PubMed ID: 20964803
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro comparison of primary stability of two implant designs in D3 bone.
    González-Serrano J; Ortega-Aranegui R; López-Quiles J
    Med Oral Patol Oral Cir Bucal; 2017 Jul; 22(4):e473-e477. PubMed ID: 28578374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bone reformation with sinus membrane elevation: a new surgical technique for maxillary sinus floor augmentation.
    Lundgren S; Andersson S; Gualini F; Sennerby L
    Clin Implant Dent Relat Res; 2004; 6(3):165-73. PubMed ID: 15726851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length.
    Sim CP; Lang NP
    Clin Oral Implants Res; 2010 Jun; 21(6):598-604. PubMed ID: 20666786
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative Assessment of the Primary Stability of Straumann BLX Implant Design Using an In Vitro Sinus Lift-Simultaneous Implant Insertion Model.
    Emmert M; Spille J; Behrens E; Ayna M; Karayürek F; Wiltfang J; Acil Y; Gülses A
    J Oral Implantol; 2022 Aug; 48(4):269-275. PubMed ID: 34494117
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A collagenated porcine bone substitute for augmentation at Neoss implant sites: a prospective 1-year multicenter case series study with histology.
    Pagliani L; Andersson P; Lanza M; Nappo A; Verrocchi D; Volpe S; Sennerby L
    Clin Implant Dent Relat Res; 2012 Oct; 14(5):746-58. PubMed ID: 20977615
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro assessment of primary stability of Straumann® implant designs.
    Romanos GE; Ciornei G; Jucan A; Malmstrom H; Gupta B
    Clin Implant Dent Relat Res; 2014 Feb; 16(1):89-95. PubMed ID: 22691157
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Reliability of 3 Resonance Frequency Analysis Devices: An In Vitro Study.
    Diker B; Diker N; Tak Ö
    J Oral Implantol; 2022 Feb; 48(1):9-14. PubMed ID: 33760051
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.