These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 27566904)

  • 1. Complex coronary bifurcation revascularization by means of very minimal crushing and ultrathin biodegradable polymer DES: Feasibility and 1-year outcomes of the "Nano-crush" technique.
    Rigatelli G; Dell'Avvocata F; Zuin M; Vassiliev D; Mazza A; Dinh HD
    Cardiovasc Revasc Med; 2017; 18(1):22-27. PubMed ID: 27566904
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Culotte versus the novel nano-crush technique for unprotected complex bifurcation left main stenting: difference in procedural time, contrast volume and X-ray exposure and 3-years outcomes.
    Rigatelli G; Zuin M; Vassilev D; Dinh H; Giatti S; Carraro M; Zanon F; Roncon L; Dung HT
    Int J Cardiovasc Imaging; 2019 Feb; 35(2):207-214. PubMed ID: 30446919
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical outcome after crush versus culotte stenting of coronary artery bifurcation lesions: the Nordic Stent Technique Study 36-month follow-up results.
    Kervinen K; Niemelä M; Romppanen H; Erglis A; Kumsars I; Maeng M; Holm NR; Lassen JF; Gunnes P; Stavnes S; Jensen JS; Galløe A; Narbute I; Sondore D; Christiansen EH; Ravkilde J; Steigen TK; Mannsverk J; Thayssen P; Hansen KN; Helqvist S; Vikman S; Wiseth R; Aarøe J; Jokelainen J; Thuesen L;
    JACC Cardiovasc Interv; 2013 Nov; 6(11):1160-5. PubMed ID: 24262616
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Complex coronary bifurcation treatment by a novel stenting technique: Bench test, fluid dynamic study and clinical outcomes.
    Rigatelli G; Zuin M; Dell'Avvocata F; Vassilev D; Daggubati R; Nguyen T; Nguyễn MTN; Foin N
    Catheter Cardiovasc Interv; 2018 Nov; 92(5):907-914. PubMed ID: 29368394
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of coronary flow conditions in complex coronary artery bifurcations stenting using computational fluid dynamics: Impact of final proximal optimization technique on different double-stent techniques.
    Rigatelli G; Zuin M; Dell'Avvocata F; Vassilev D; Daggubati R; Nguyen T; Van Viet Thang N; Foin N
    Cardiovasc Revasc Med; 2017 Jun; 18(4):233-240. PubMed ID: 28108202
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term outcomes of bifurcation lesions after implantation of drug-eluting stents with the "mini-crush technique".
    Galassi AR; Colombo A; Buchbinder M; Grasso C; Tomasello SD; Ussia GP; Tamburino C
    Catheter Cardiovasc Interv; 2007 Jun; 69(7):976-83. PubMed ID: 17295334
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Angiographic and clinical outcomes after implantation of drug eluting stents in bifurcation lesions with crush or kissing stent technique.
    Cheema AN; Jolly SS; Burstein JM; Sharieff W; Mohammad A; Yeoh E; Mancini GB; Cantor WJ; Kutryk MJ; Strauss BH; Chisholm RJ
    J Interv Cardiol; 2013 Apr; 26(2):145-52. PubMed ID: 23406435
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Long-term clinical and angiographic outcomes after implantation of sirolimus-eluting stents with a "modified mini-crush" technique in coronary bifurcation lesions.
    Yang HM; Tahk SJ; Woo SI; Lim HS; Choi BJ; Choi SY; Yoon MH; Park JS; Zheng M; Hwang GS; Kang SJ; Shin JH
    Catheter Cardiovasc Interv; 2009 Jul; 74(1):76-84. PubMed ID: 19360861
    [TBL] [Abstract][Full Text] [Related]  

  • 9. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
    Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Paclitaxel-eluting balloon and everolimus-eluting stent for provisional stenting of coronary bifurcations: 12-month results of the multicenter BIOLUX-I study.
    Worthley S; Hendriks R; Worthley M; Whelan A; Walters DL; Whitbourn R; Meredith I
    Cardiovasc Revasc Med; 2015; 16(7):413-7. PubMed ID: 26346023
    [TBL] [Abstract][Full Text] [Related]  

  • 11. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.
    Wang G; Sun Z; Jin Q; Xu K; Li Y; Wang X; Ma Y; Liu H; Zhao X; Wang B; Deng J; Guan S; Ge M; Wang X; Xu B; Han Y
    Catheter Cardiovasc Interv; 2015 Mar; 85 Suppl 1():744-51. PubMed ID: 25630447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.
    Serruys PW; Farooq V; Kalesan B; de Vries T; Buszman P; Linke A; Ischinger T; Klauss V; Eberli F; Wijns W; Morice MC; Di Mario C; Corti R; Antoni D; Sohn HY; Eerdmans P; Rademaker-Havinga T; van Es GA; Meier B; Jüni P; Windecker S
    JACC Cardiovasc Interv; 2013 Aug; 6(8):777-89. PubMed ID: 23968698
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations.
    Costopoulos C; Latib A; Naganuma T; Sticchi A; Ferrarello S; Regazzoli D; Chieffo A; Figini F; Carlino M; Montorfano M; Naim C; Kawaguchi M; Gerasimou A; Giannini F; Godino C; Colombo A
    Catheter Cardiovasc Interv; 2014 May; 83(6):889-95. PubMed ID: 23804318
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial.
    Gao RL; Xu B; Lansky AJ; Yang YJ; Ma CS; Han YL; Chen SL; Li H; Zhang RY; Fu GS; Yuan ZY; Jiang H; Huo Y; Li W; Zhang YJ; Leon MB;
    EuroIntervention; 2013 May; 9(1):75-83. PubMed ID: 23685298
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of coronary anatomy and stenting technique on long-term outcome after drug-eluting stent implantation for unprotected left main coronary artery disease.
    Tiroch K; Mehilli J; Byrne RA; Schulz S; Massberg S; Laugwitz KL; Vorpahl M; Seyfarth M; Kastrati A;
    JACC Cardiovasc Interv; 2014 Jan; 7(1):29-36. PubMed ID: 24332416
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Angiographic and clinical outcomes of patients treated with everolimus-eluting bioresorbable stents in routine clinical practice: Results of the ISAR-ABSORB registry.
    Hoppmann P; Kufner S; Cassese S; Wiebe J; Schneider S; Pinieck S; Scheler L; Bernlochner I; Joner M; Schunkert H; Laugwitz KL; Kastrati A; Byrne RA
    Catheter Cardiovasc Interv; 2016 Apr; 87(5):822-9. PubMed ID: 26708019
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial.
    Stella PR; Belkacemi A; Dubois C; Nathoe H; Dens J; Naber C; Adriaenssens T; van Belle E; Doevendans P; Agostoni P
    Catheter Cardiovasc Interv; 2012 Dec; 80(7):1138-46. PubMed ID: 22422607
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Clinical and angiographic outcomes after implantation of drug-eluting stents in bifurcation lesions with the crush stent technique].
    Cohen R; Foucher R; Sfaxi A; Hakim M; Domniez T; Elhadad S
    Ann Cardiol Angeiol (Paris); 2009 Aug; 58(4):208-14. PubMed ID: 19457465
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real polymer-free sirolimus- and probucol-eluting versus biodegradable polymer sirolimus-eluting stents for obstructive coronary artery disease: DKPLUS-Wave 1, a multicenter, randomized, prospective trial.
    Chen SL; Ye F; Zhang JJ; Zou JJ; Qian XS; Li F; Yang S; Ge Z; Shan SJ; Li XB; Xu T; Kan J; Lin L; Han YL
    Cardiovasc Ther; 2013 Aug; 31(4):193-200. PubMed ID: 22954234
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The long-term clinical outcome of T-stenting and small protrusion technique for coronary bifurcation lesions.
    Naganuma T; Latib A; Basavarajaiah S; Chieffo A; Figini F; Carlino M; Montorfano M; Godino C; Ferrarello S; Hasegawa T; Kawaguchi M; Nakamura S; Colombo A
    JACC Cardiovasc Interv; 2013 Jun; 6(6):554-61. PubMed ID: 23683737
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.