406 related articles for article (PubMed ID: 27566982)
1. Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing.
Galbraith JG; Daly CJ; Harty JA; Dailey HL
Clin Biomech (Bristol, Avon); 2016 Oct; 38():42-9. PubMed ID: 27566982
[TBL] [Abstract][Full Text] [Related]
2. The role of fibular fixation in combined fractures of the tibia and fibula: a biomechanical investigation.
Weber TG; Harrington RM; Henley MB; Tencer AF
J Orthop Trauma; 1997 Apr; 11(3):206-11. PubMed ID: 9181505
[TBL] [Abstract][Full Text] [Related]
3. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
[TBL] [Abstract][Full Text] [Related]
4. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation.
Morin PM; Reindl R; Harvey EJ; Beckman L; Steffen T
Can J Surg; 2008 Feb; 51(1):45-50. PubMed ID: 18248705
[TBL] [Abstract][Full Text] [Related]
5. Effect of fibular plate fixation on rotational stability of simulated distal tibial fractures treated with intramedullary nailing.
Kumar A; Charlebois SJ; Cain EL; Smith RA; Daniels AU; Crates JM
J Bone Joint Surg Am; 2003 Apr; 85(4):604-8. PubMed ID: 12672833
[TBL] [Abstract][Full Text] [Related]
6. The Flexible Axial Stimulation (FAST) intramedullary nail provides interfragmentary micromotion and enhanced torsional stability.
Dailey HL; Daly CJ; Galbraith JG; Cronin M; Harty JA
Clin Biomech (Bristol, Avon); 2013 Jun; 28(5):579-85. PubMed ID: 23684088
[TBL] [Abstract][Full Text] [Related]
7. The influence of distal locking on the need for fibular plating in intramedullary nailing of distal metaphyseal tibiofibular fractures.
Attal R; Maestri V; Doshi HK; Onder U; Smekal V; Blauth M; Schmoelz W
Bone Joint J; 2014 Mar; 96-B(3):385-9. PubMed ID: 24589796
[TBL] [Abstract][Full Text] [Related]
8. Does fibular plating improve alignment after intramedullary nailing of distal metaphyseal tibia fractures?
Egol KA; Weisz R; Hiebert R; Tejwani NC; Koval KJ; Sanders RW
J Orthop Trauma; 2006 Feb; 20(2):94-103. PubMed ID: 16462561
[TBL] [Abstract][Full Text] [Related]
9. Are extra locking bolts or fibular plating more important in extreme nailing of distal tibia fractures? A cadaveric biomechanical analysis.
Cunningham DJ; Lawrence JE; Kovvur M; Turner KE; Oppizzi G; Xu D; Zhang LQ; Johnson DJ; Mittwede P; Sepehri A; Brand J; O'Toole RV; Gage MJ
Injury; 2024 Jun; 55(6):111540. PubMed ID: 38622039
[TBL] [Abstract][Full Text] [Related]
10. Distal leg fractures: How critical is the fibular fracture and its fixation?
Bonnevialle P; Lafosse JM; Pidhorz L; Poichotte A; Asencio G; Dujardin F;
Orthop Traumatol Surg Res; 2010 Oct; 96(6):667-73. PubMed ID: 20851076
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures.
Högel F; Hoffmann S; Panzer S; Wimber J; Bühren V; Augat P
Arch Orthop Trauma Surg; 2013 Jan; 133(1):59-64. PubMed ID: 23076657
[TBL] [Abstract][Full Text] [Related]
14. Does Concurrent Tibial Intramedullary Nailing and Fibular Fixation Increase Rates of Tibial Nonunion? A Matched Cohort Study.
Githens M; Haller J; Agel J; Firoozabadi R
J Orthop Trauma; 2017 Jun; 31(6):316-320. PubMed ID: 28538453
[TBL] [Abstract][Full Text] [Related]
15. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
[TBL] [Abstract][Full Text] [Related]
16. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
[TBL] [Abstract][Full Text] [Related]
17. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
[TBL] [Abstract][Full Text] [Related]
18. Intramedullary tibial nailing of distal tibiofibular fractures: additional fibular fixation or not?
Van Maele M; Molenaers B; Geusens E; Nijs S; Hoekstra H
Eur J Trauma Emerg Surg; 2018 Jun; 44(3):433-441. PubMed ID: 28584887
[TBL] [Abstract][Full Text] [Related]
19. Biomechanics of the Injured Fibula Following Plate Fixation of a Concomitant Tibia Fracture To Fix or Not to Fix?
Onyekwelu I; Sinicrope BJ; Riehl JT; Roberts CS; Voor MJ
Bull Hosp Jt Dis (2013); 2018 Sep; 76(3):176-182. PubMed ID: 31513521
[TBL] [Abstract][Full Text] [Related]
20. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]