557 related articles for article (PubMed ID: 27572616)
1. Incidence and predictors of new-onset atrioventricular block requiring pacemaker implantation after sutureless aortic valve replacement.
Toledano B; Bisbal F; Camara ML; Labata C; Berastegui E; Gálvez-Montón C; Villuendas R; Sarrias A; Oliveres T; Pereferrer D; Ruyra X; Bayés-Genís A
Interact Cardiovasc Thorac Surg; 2016 Dec; 23(6):861-868. PubMed ID: 27572616
[TBL] [Abstract][Full Text] [Related]
2. Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?
Vogt F; Pfeiffer S; Dell'Aquila AM; Fischlein T; Santarpino G
Interact Cardiovasc Thorac Surg; 2016 Mar; 22(3):253-8. PubMed ID: 26614526
[TBL] [Abstract][Full Text] [Related]
3. Postoperative conduction disorders after implantation of the self-expandable sutureless Perceval S bioprosthesis.
van Boxtel AG; Houthuizen P; Hamad MA; Sjatskig J; Tan E; Prinzen FW; van Straten AH
J Heart Valve Dis; 2014 May; 23(3):319-24. PubMed ID: 25296456
[TBL] [Abstract][Full Text] [Related]
4. Patients without prolonged QRS after TAVI with CoreValve device do not experience high-degree atrio-ventricular block.
Mouillet G; Lellouche N; Lim P; Meguro K; Yamamoto M; Deux JF; Monin JL; Bergoënd E; Dubois-Randé JL; Teiger E
Catheter Cardiovasc Interv; 2013 Apr; 81(5):882-7. PubMed ID: 22972678
[TBL] [Abstract][Full Text] [Related]
5. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
[TBL] [Abstract][Full Text] [Related]
6. Conduction Disorders After Sutureless Aortic Valve Replacement.
Bouhout I; Mazine A; Rivard L; Ghoneim A; El-Hamamsy I; Lamarche Y; Carrier M; Demers P; Bouchard D
Ann Thorac Surg; 2017 Apr; 103(4):1254-1260. PubMed ID: 27717423
[TBL] [Abstract][Full Text] [Related]
7. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
[TBL] [Abstract][Full Text] [Related]
8. Electrocardiographic and clinical predictors of permanent pacemaker insertion following Perceval sutureless aortic valve implantation.
Mugnai G; Moran D; Nijs J; Chierchia GB; Velagic V; Ströker E; Hunuk B; Czapla J; Brugada P; La Meir M; de Asmundis C
J Electrocardiol; 2019; 56():10-14. PubMed ID: 31229677
[TBL] [Abstract][Full Text] [Related]
9. Predictors for new-onset conduction block in patients with pure native aortic regurgitation after transcatheter aortic valve replacement with a new-generation self-expanding valve (VitaFlow Liberty
Zhang X; Liang C; Zha L; Zuo Q; Hu G; Ding J; Tang S
BMC Cardiovasc Disord; 2024 Jan; 24(1):77. PubMed ID: 38281925
[TBL] [Abstract][Full Text] [Related]
10. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve.
Urena M; Mok M; Serra V; Dumont E; Nombela-Franco L; DeLarochellière R; Doyle D; Igual A; Larose E; Amat-Santos I; Côté M; Cuéllar H; Pibarot P; de Jaegere P; Philippon F; Garcia del Blanco B; Rodés-Cabau J
J Am Coll Cardiol; 2012 Oct; 60(18):1743-52. PubMed ID: 23040577
[TBL] [Abstract][Full Text] [Related]
11. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
[TBL] [Abstract][Full Text] [Related]
12. New postoperative conduction abnormalities after the implantation of a rapid-deployment aortic valve prosthesis.
Mogilansky C; Balan R; Deutsch C; Czesla M; Massoudy P
Interact Cardiovasc Thorac Surg; 2019 Apr; 28(4):581-586. PubMed ID: 30412244
[TBL] [Abstract][Full Text] [Related]
13. High-degree atrioventricular block in patients with preexisting bundle branch block or bundle branch block occurring during transcatheter aortic valve implantation.
Egger F; Nürnberg M; Rohla M; Weiss TW; Unger G; Smetana P; Geppert A; Gruber SC; Bambazek A; Falkensammer J; Waldenberger FR; Huber K; Freynhofer MK
Heart Rhythm; 2014 Dec; 11(12):2176-82. PubMed ID: 25034184
[TBL] [Abstract][Full Text] [Related]
14. Atrioventricular block after transcatheter balloon expandable aortic valve implantation.
Sinhal A; Altwegg L; Pasupati S; Humphries KH; Allard M; Martin P; Cheung A; Ye J; Kerr C; Lichtenstein SV; Webb JG
JACC Cardiovasc Interv; 2008 Jun; 1(3):305-9. PubMed ID: 19463318
[TBL] [Abstract][Full Text] [Related]
15. Sutureless and Transcatheter Aortic Valve Replacement: When Rivals Become Allies.
Ellouze M; Mazine A; Carrier M; Bouchard D
Semin Thorac Cardiovasc Surg; 2020 Autumn; 32(3):427-430. PubMed ID: 31330180
[TBL] [Abstract][Full Text] [Related]
16. Sutureless versus Transfemoral Transcatheter Aortic Valve Implant: A Propensity Score Matching Study.
Santarpino G; Vogt F; Pfeiffer S; Dell'Aquila AM; Jessl J; Cuomo F; von Wardenburg C; Fischlein T; Pauschinger M; Schwab J
J Heart Valve Dis; 2017 May; 26(3):255-261. PubMed ID: 29092108
[TBL] [Abstract][Full Text] [Related]
17. Early Conduction Disorders After Aortic Valve Replacement With the Sutureless Perceval Prosthesis.
Verlinden J; Bové T; de Kerchove L; Baert J; Radermecker M; Durieux R; Gutermann H; Van Kerrebroeck C; Szecel D; Meuris B
Ann Thorac Surg; 2022 Jun; 113(6):1911-1917. PubMed ID: 34536377
[TBL] [Abstract][Full Text] [Related]
18. Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis.
Ferreira ND; Caeiro D; Adão L; Oliveira M; Gonçalves H; Ribeiro J; Teixeira M; Albuquerque A; Primo J; Braga P; Simões L; Ribeiro VG
Pacing Clin Electrophysiol; 2010 Nov; 33(11):1364-72. PubMed ID: 20723083
[TBL] [Abstract][Full Text] [Related]
19. Permanent pacemaker implantation after isolated aortic valve replacement: incidence, risk factors and surgical technical aspects.
Nardi P; Pellegrino A; Scafuri A; Bellos K; De Propris S; Polisca P; Chiariello L
J Cardiovasc Med (Hagerstown); 2010 Jan; 11(1):14-9. PubMed ID: 19829137
[TBL] [Abstract][Full Text] [Related]
20. Immediate outcome after sutureless versus transcatheter aortic valve replacement.
Biancari F; Barbanti M; Santarpino G; Deste W; Tamburino C; Gulino S; Immè S; Di Simone E; Todaro D; Pollari F; Fischlein T; Kasama K; Meuris B; Dalén M; Sartipy U; Svenarud P; Lahtinen J; Heikkinen J; Juvonen T; Gatti G; Pappalardo A; Mignosa C; Rubino AS
Heart Vessels; 2016 Mar; 31(3):427-33. PubMed ID: 25573258
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]