These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 27574322)

  • 1. PATIENT SIZE BASED GUIDING EQUATIONS FOR AUTOMATIC mAs AND kVp SELECTIONS IN GENERAL MEDICAL X-RAY PROJECTION RADIOGRAPHY.
    Zheng X
    Radiat Prot Dosimetry; 2017 May; 174(4):545-550. PubMed ID: 27574322
    [TBL] [Abstract][Full Text] [Related]  

  • 2. General equations for optimal selection of diagnostic image acquisition parameters in clinical X-ray imaging.
    Zheng X
    Radiol Phys Technol; 2017 Dec; 10(4):415-421. PubMed ID: 28822074
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Body size and tube voltage-dependent guiding equations for optimal selection of image acquisition parameters in clinical X-ray imaging.
    Zheng X
    Radiol Phys Technol; 2018 Jun; 11(2):212-218. PubMed ID: 29667102
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system.
    Huda W; Sajewicz AM; Ogden KM; Dance DR
    Med Phys; 2003 Mar; 30(3):442-8. PubMed ID: 12674245
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.
    Brisse HJ; Madec L; Gaboriaud G; Lemoine T; Savignoni A; Neuenschwander S; Aubert B; Rosenwald JC
    Med Phys; 2007 Jul; 34(7):3018-33. PubMed ID: 17822010
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A qualitative and quantitative analysis of radiation dose and image quality of computed tomography images using adaptive statistical iterative reconstruction.
    Hussain FA; Mail N; Shamy AM; Suliman A; Saoudi A
    J Appl Clin Med Phys; 2016 May; 17(3):419-432. PubMed ID: 27167261
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using 100- instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality.
    Björkdahl P; Nyman U
    Acta Radiol; 2010 Apr; 51(3):260-70. PubMed ID: 20121673
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Synthetic CT: simulating low dose single and dual energy protocols from a dual energy scan.
    Wang AS; Pelc NJ
    Med Phys; 2011 Oct; 38(10):5551-62. PubMed ID: 21992373
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dose optimization in pediatric cardiac x-ray imaging.
    Gislason AJ; Davies AG; Cowen AR
    Med Phys; 2010 Oct; 37(10):5258-69. PubMed ID: 21089760
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: a phantom study.
    Schindera ST; Winklehner A; Alkadhi H; Goetti R; Fischer M; Gnannt R; Szucs-Farkas Z
    Clin Radiol; 2013 Feb; 68(2):e79-86. PubMed ID: 23219454
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients: Initial experience with 3
    Hagelstein C; Henzler T; Haubenreisser H; Meyer M; Sudarski S; Schoenberg SO; Neff KW; Weis M
    Z Med Phys; 2016 Dec; 26(4):349-361. PubMed ID: 26702762
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimal multidetector row CT parameters for evaluations of the breast: a phantom and specimen study.
    Yi A; Seo BK; Cho PK; Pisano ED; Lee KY; Je BK; Kim HY; Min BW; Son GS
    Acad Radiol; 2010 Jun; 17(6):744-51. PubMed ID: 20457417
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic CT simulation optimization for radiation therapy: A general strategy.
    Li H; Yu L; Anastasio MA; Chen HC; Tan J; Gay H; Michalski JM; Low DA; Mutic S
    Med Phys; 2014 Mar; 41(3):031913. PubMed ID: 24593731
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Association between subjective evaluation and physical parameters for radiographic images optimization.
    Alves AF; Alvarez M; Ribeiro SM; Duarte SB; Miranda JR; Pina DR
    Phys Med; 2016 Jan; 32(1):123-32. PubMed ID: 26573131
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultra-low peak voltage CT colonography: effect of iterative reconstruction algorithms on performance of radiologists who use anthropomorphic colonic phantoms.
    Shin CI; Kim SH; Lee ES; Lee DH; Hwang EJ; Chung SY; Lee JM; Han JK; Choi BI
    Radiology; 2014 Dec; 273(3):759-71. PubMed ID: 25010640
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study.
    Schindera ST; Nelson RC; Yoshizumi T; Toncheva G; Nguyen G; DeLong DM; Szucs-Farkas Z
    Acad Radiol; 2009 Aug; 16(8):997-1002. PubMed ID: 19409820
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Circle of Willis at CT angiography: dose reduction and image quality--reducing tube voltage and increasing tube current settings.
    Waaijer A; Prokop M; Velthuis BK; Bakker CJ; de Kort GA; van Leeuwen MS
    Radiology; 2007 Mar; 242(3):832-9. PubMed ID: 17229873
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimising automatic exposure control in computed radiography and the impact on patient dose.
    Doyle P; Gentle D; Martin CJ
    Radiat Prot Dosimetry; 2005; 114(1-3):236-9. PubMed ID: 15933114
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography.
    Gkanatsios NA; Huda W; Peters KR
    Med Phys; 2002 Aug; 29(8):1643-50. PubMed ID: 12201409
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluating radiographic parameters for mobile chest computed radiography: phantoms, image quality and effective dose.
    Rill LN; Brateman L; Arreola M
    Med Phys; 2003 Oct; 30(10):2727-35. PubMed ID: 14596311
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.