These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 27574327)

  • 1. SINGLE ANODE TRIPLE GEM TISSUE EQUIVALENT PROPORTIONAL COUNTER AS THE BASIS FOR A PERSONAL NEUTRON DOSIMETER.
    Seydaliev M; Dubeau J; Ali F
    Radiat Prot Dosimetry; 2017 Apr; 174(3):337-347. PubMed ID: 27574327
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microdosimetric Measurements in Gamma and neutron Fields with a Tissue Equivalent Proportional Counter Based on a Gas Electron Multiplier.
    De Nardo L; Dal Corso F; Pegoraro M
    Radiat Prot Dosimetry; 2017 Jun; 175(2):260-266. PubMed ID: 27881795
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and test of a GEM-based TEPC for neutron protection dosimetry.
    Wang CK; Seidaliev M; Mandapaka A
    Health Phys; 2008 May; 94(5):440-8. PubMed ID: 18403965
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Neutron microdosimetric response of a gas electron multiplier.
    Dubeau J; Waker AJ
    Radiat Prot Dosimetry; 2008; 128(4):413-20. PubMed ID: 17951607
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of an advanced two-dimensional microdosimetric detector based on THick Gas Electron Multipliers.
    Darvish-Molla S; Prestwich WV; Byun SH
    Med Phys; 2018 Mar; 45(3):1241-1254. PubMed ID: 29344955
    [TBL] [Abstract][Full Text] [Related]  

  • 6. DOSIMETRIC response of a REM-500 in low energy neutron fields typical of nuclear power plants.
    Aslam ; Matysiak W; Atanackovic J; Waker AJ
    Health Phys; 2012 Jun; 102(6):603-13. PubMed ID: 22570919
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and simulation of a GEM-based TEPC as a neutron REM meter.
    Wang CK; Seidaliev M; Mandapaka AK
    Radiat Prot Dosimetry; 2007; 126(1-4):559-63. PubMed ID: 17502312
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo Simulations Comparing the Response of a Novel Hemispherical Tepc to Existing Spherical and Cylindrical Tepcs for Neutron Monitoring and Dosimetry.
    Broughton DP; Waker AJ
    Health Phys; 2017 May; 112(5):430-438. PubMed ID: 28350696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of a new tissue equivalent proportional counter for dosimetry of neutron and photon fields: comparison of measurements and Monte Carlo simulations.
    Malimban J; Nam UW; Pyo J; Youn S; Ye SJ
    Phys Med Biol; 2019 Sep; 64(17):17NT02. PubMed ID: 31269471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Environmental neutron measurements around nuclear facilities with moderated-type neutron detector.
    Nakamura T; Kosako T; Iwai S
    Health Phys; 1984 Nov; 47(5):729-43. PubMed ID: 6511417
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Study of microdosimetric energy deposition patterns in tissue-equivalent medium due to low-energy neutron fields using a graphite-walled proportional counter.
    Waker AJ; Aslam
    Radiat Res; 2011 Jun; 175(6):806-13. PubMed ID: 21476858
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of a cylindrical tissue-equivalent proportional counter for use in neutron monitoring.
    Chau Q; Lahaye T; Ménard S; Donadille L; Bolognese T; Rannou A
    Radiat Prot Dosimetry; 2004; 110(1-4):297-300. PubMed ID: 15353662
    [TBL] [Abstract][Full Text] [Related]  

  • 13. THE DETERMINATION OF NEUTRON FLUENCE TO ABSORBED DOSE CONVERSION COEFFICIENTS AND RELATIVE BIOLOGICAL EFFECT BASED ON MICRODOSIMETRY MEASUREMENTS.
    Zhang W; Li C; Zou Y; Liu Y; Luo H
    Radiat Prot Dosimetry; 2019 Dec; 187(2):262-267. PubMed ID: 31251366
    [TBL] [Abstract][Full Text] [Related]  

  • 14. First microdosimetric measurements with a TEPC based on a GEM.
    Farahmand M; Bos AJ; De Nardo L; van Eijk CW
    Radiat Prot Dosimetry; 2004; 110(1-4):839-43. PubMed ID: 15353756
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems.
    Farah J; Mares V; Romero-Expósito M; Trinkl S; Domingo C; Dufek V; Klodowska M; Kubancak J; Knežević Ž; Liszka M; Majer M; Miljanić S; Ploc O; Schinner K; Stolarczyk L; Trompier F; Wielunski M; Olko P; Harrison RM
    Med Phys; 2015 May; 42(5):2572-84. PubMed ID: 25979049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MICRODOSIMETRIC MEASUREMENTS OF A TISSUE-EQUIVALENT PROPORTIONAL COUNTER BASED ON A GAS ELECTRON MULTIPLIER DOWN TO 140 nm SIMULATED SITE SIZES.
    Farahmand M; De Nardo L
    Radiat Prot Dosimetry; 2016 Nov; 171(3):304-312. PubMed ID: 26359335
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of lineal-energy distributions for neutrons of 8 keV to 65 MeV by using a tissue-equivalent proportional counter.
    Nunomiya T; Kim E; Kurosaw T; Taniguchi S; Nakamura T; Nakane Y; Sakamoto Y; Tanaka S
    Radiat Prot Dosimetry; 2002; 102(1):49-59. PubMed ID: 12212902
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intercomparison of Monte Carlo radiation transport codes to model TEPC response in low-energy neutron and gamma-ray fields.
    Ali F; Waker AJ; Waller EJ
    Radiat Prot Dosimetry; 2014 Oct; 161(1-4):257-60. PubMed ID: 24162375
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications.
    Aslam ; Prestwich WV; McNeill FE; Waker AJ
    Radiat Prot Dosimetry; 2003; 103(4):311-22. PubMed ID: 12797554
    [TBL] [Abstract][Full Text] [Related]  

  • 20. TISSUE-EQUIVALENCE OF H2 GAS FOR MICRODOSIMETRY IN NEUTRON FIELDS: A GEANT4 MONTE CARLO STUDY.
    Chattaraj A; Selvam TP
    Radiat Prot Dosimetry; 2021 Dec; 197(3-4):202-211. PubMed ID: 34977947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.