160 related articles for article (PubMed ID: 27577701)
1. Positive detection of exfoliated colon cancer cells on linear stapler cartridges was associated with depth of tumor invasion and preoperative bowel preparation in colon cancer.
Ikehara K; Endo S; Kumamoto K; Hidaka E; Ishida F; Tanaka J; Kudo SE
World J Surg Oncol; 2016 Aug; 14(1):233. PubMed ID: 27577701
[TBL] [Abstract][Full Text] [Related]
2. Influence of multiple stapler firings used for rectal division on colorectal anastomotic leak rate.
Braunschmid T; Hartig N; Baumann L; Dauser B; Herbst F
Surg Endosc; 2017 Dec; 31(12):5318-5326. PubMed ID: 28634627
[TBL] [Abstract][Full Text] [Related]
3. A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis.
Mori S; Kita Y; Baba K; Tanabe K; Wada M; Yoshino S; Nishida N; Iino S; Setoyama T; Maemura K; Ohtsuka T
Colorectal Dis; 2024 Apr; 26(4):754-759. PubMed ID: 38443753
[TBL] [Abstract][Full Text] [Related]
4. Risk factors for anastomotic leakage after laparoscopic intracorporeal colorectal anastomosis with a double stapling technique.
Kim JS; Cho SY; Min BS; Kim NK
J Am Coll Surg; 2009 Dec; 209(6):694-701. PubMed ID: 19959036
[TBL] [Abstract][Full Text] [Related]
5. Single-Incision Laparoscopic Anterior Resection Using a Curved Stapler.
Watanabe J; Ota M; Suwa Y; Ishibe A; Masui H; Nagahori K
Dis Colon Rectum; 2016 Nov; 59(11):1105-1109. PubMed ID: 27749488
[TBL] [Abstract][Full Text] [Related]
6. Technical characteristics can make the difference in a surgical linear stapler. Or not?
Giaccaglia V; Antonelli MS; Addario Chieco P; Cocorullo G; Cavallini M; Gulotta G
J Surg Res; 2015 Jul; 197(1):101-6. PubMed ID: 25918006
[TBL] [Abstract][Full Text] [Related]
7. [Total laparoscopic left colectomy intracorporeal anastomosis].
He L; Chen Y; Wang Q
Zhonghua Wei Chang Wai Ke Za Zhi; 2020 Nov; 23(11):1110-1112. PubMed ID: 33212564
[TBL] [Abstract][Full Text] [Related]
8. Circular stapler introducer: a novel device to facilitate stapled colorectal anastomosis.
Guweidhi A; Steffen R; Metzger A; Teuscher J; Flückiger P; Z'graggen K
Dis Colon Rectum; 2009 Apr; 52(4):746-8. PubMed ID: 19404085
[TBL] [Abstract][Full Text] [Related]
9. Dysmotility by mechanical bowel preparation using polyethylene glycol.
Yamada T; Kan H; Matsumoto S; Koizumi M; Matsuda A; Shinji S; Sasaki J; Uchida E
J Surg Res; 2014 Sep; 191(1):84-90. PubMed ID: 24857541
[TBL] [Abstract][Full Text] [Related]
10. Extent of intraluminal exfoliated malignant cells during surgery for colon cancer: Differences in cell abundance ratio between laparoscopic and open surgery.
Kobayashi S; Inoue Y; Fujita F; Ito S; Yamaguchi I; Nakayama M; Kanetaka K; Takatsuki M; Eguchi S
Asian J Endosc Surg; 2019 Apr; 12(2):145-149. PubMed ID: 29992749
[TBL] [Abstract][Full Text] [Related]
11. Assessment of a circular powered stapler for creation of anastomosis in left-sided colorectal surgery: A prospective cohort study.
Herzig DO; Ogilvie JW; Chudzinski A; Ferrara A; Ashraf SQ; Jimenez-Rodriguez RM; Van der Speeten K; Kinross J; Schimmelpenning H; Sagar PM; Cannon JA; Schwiers ML; Singleton DW; Waggoner JR; Fryrear R; Sylla P
Int J Surg; 2020 Dec; 84():140-146. PubMed ID: 33176211
[TBL] [Abstract][Full Text] [Related]
12. The impact of bowel preparation on the severity of anastomotic leak in colon cancer patients.
Haskins IN; Fleshman JW; Amdur RL; Agarwal S
J Surg Oncol; 2016 Dec; 114(7):810-813. PubMed ID: 27634398
[TBL] [Abstract][Full Text] [Related]
13. [Benefits of mechanical suture in our experience].
Coroş MF; Sorlea S; Crăciun C; Rareş G; Pascarenco G; Corhan T; György C
Chirurgia (Bucur); 2012; 107(3):325-31. PubMed ID: 22844830
[TBL] [Abstract][Full Text] [Related]
14. Right hemicolectomy: mechanical bowel preparation is not required.
Jansen JO; O'Kelly TJ; Krukowski ZH; Keenan RA
J R Coll Surg Edinb; 2002 Jun; 47(3):557-60. PubMed ID: 12109610
[TBL] [Abstract][Full Text] [Related]
15. Triangulating stapling technique for reconstruction after colectomy.
Fukunaga Y; Higashino M; Tanimura S; Osugi H
Hepatogastroenterology; 2007 Mar; 54(74):414-7. PubMed ID: 17523286
[TBL] [Abstract][Full Text] [Related]
16. Is mechanical bowel preparation mandatory for left-sided colonic anastomosis? Results of a prospective randomized trial.
Zmora O; Mahajna A; Bar-Zakai B; Hershko D; Shabtai M; Krausz MM; Ayalon A
Tech Coloproctol; 2006 Jul; 10(2):131-5. PubMed ID: 16773286
[TBL] [Abstract][Full Text] [Related]
17. Laparoscopic colorectal anastomosis using the novel Chex(®) circular stapler: a case-control study.
Maggiori L; Bretagnol F; Ferron M; Chevalier Y; Panis Y
Colorectal Dis; 2011 Jun; 13(6):711-5. PubMed ID: 20184634
[TBL] [Abstract][Full Text] [Related]
18. Exfoliated malignant cells at the anastomosis site in colon cancer surgery: the impact of surgical bowel occlusion and intraluminal cleaning.
Hasegawa J; Nishimura J; Yamamoto S; Yoshida Y; Iwase K; Kawano K; Nezu R
Int J Colorectal Dis; 2011 Jul; 26(7):875-80. PubMed ID: 21302117
[TBL] [Abstract][Full Text] [Related]
19. Mechanical bowel preparation or not? Outcome of a multicenter, randomized trial in elective open colon surgery.
Fa-Si-Oen P; Roumen R; Buitenweg J; van de Velde C; van Geldere D; Putter H; Verwaest C; Verhoef L; de Waard JW; Swank D; D'Hoore A; Croiset van Uchelen F
Dis Colon Rectum; 2005 Aug; 48(8):1509-16. PubMed ID: 15981065
[TBL] [Abstract][Full Text] [Related]
20. The circular stapling device as a risk factor for anastomotic leakage.
Folkesson J; Nilsson J; Påhlman L; Glimelius B; Gunnarsson U
Colorectal Dis; 2004 Jul; 6(4):275-9. PubMed ID: 15206973
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]