217 related articles for article (PubMed ID: 27580519)
1. Multi-phase passband balanced SSFP fMRI with 50ms sampling rate at 7Tesla enables high precision in resolving 100ms neuronal events.
Chen Z; Xue R; Zhang P; Sun K; Zuo Z; An J; Chen J; He S; Chen L; Wang DJJ
Magn Reson Imaging; 2017 Jan; 35():20-28. PubMed ID: 27580519
[TBL] [Abstract][Full Text] [Related]
2. Integrated SSFP for functional brain mapping at 7T with reduced susceptibility artifact.
Sun K; Xue R; Zhang P; Zuo Z; Chen Z; Wang B; Martin T; Wang Y; Chen L; He S; Wang DJJ
J Magn Reson; 2017 Mar; 276():22-30. PubMed ID: 28092785
[TBL] [Abstract][Full Text] [Related]
3. Fat-suppressed alternating-SSFP for whole-brain fMRI using breath-hold and visual stimulus paradigms.
Jou T; Patterson S; Pauly JM; Bowen CV
Magn Reson Med; 2016 May; 75(5):1978-88. PubMed ID: 26037220
[TBL] [Abstract][Full Text] [Related]
4. Full-brain coverage and high-resolution imaging capabilities of passband b-SSFP fMRI at 3T.
Lee JH; Dumoulin SO; Saritas EU; Glover GH; Wandell BA; Nishimura DG; Pauly JM
Magn Reson Med; 2008 May; 59(5):1099-110. PubMed ID: 18421687
[TBL] [Abstract][Full Text] [Related]
5. High-resolution mapping of neuronal activation with balanced SSFP at 9.4 tesla.
Scheffler K; Ehses P
Magn Reson Med; 2016 Jul; 76(1):163-71. PubMed ID: 26302451
[TBL] [Abstract][Full Text] [Related]
6. Multi-echo balanced SSFP with a sequential phase-encoding order for functional MR imaging at 7T.
Liang H; Pan Z; Qian C; Liu C; Sun K; Weng D; An J; Zhuo Y; Wang DJJ; Guo H; Xue R
Magn Reson Med; 2022 Sep; 88(3):1303-1313. PubMed ID: 35657055
[TBL] [Abstract][Full Text] [Related]
7. Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla.
Zhong K; Leupold J; Hennig J; Speck O
Magn Reson Med; 2007 Jan; 57(1):67-73. PubMed ID: 17191247
[TBL] [Abstract][Full Text] [Related]
8. Effects of phase regression on high-resolution functional MRI of the primary visual cortex.
Stanley OW; Kuurstra AB; Klassen LM; Menon RS; Gati JS
Neuroimage; 2021 Feb; 227():117631. PubMed ID: 33316391
[TBL] [Abstract][Full Text] [Related]
9. Comparison between multi-shot gradient echo EPI and balanced SSFP in unenhanced 3T MRA of thoracic aorta in healthy volunteers.
Iyama Y; Nakaura T; Nagayama Y; Oda S; Utsunomiya D; Kidoh M; Yuki H; Hirata K; Namimoto T; Kitajima M; Morita K; Funama Y; Takemura A; Tokuyasu S; Okuaki T; Yamashita Y
Eur J Radiol; 2017 Nov; 96():85-90. PubMed ID: 29103481
[TBL] [Abstract][Full Text] [Related]
10. Signal and noise characteristics of SSFP FMRI: a comparison with GRE at multiple field strengths.
Miller KL; Smith SM; Jezzard P; Wiggins GC; Wiggins CJ
Neuroimage; 2007 Oct; 37(4):1227-36. PubMed ID: 17706432
[TBL] [Abstract][Full Text] [Related]
11. Multi-slice passband bSSFP for human and rodent fMRI at ultra-high field.
Reynaud O; da Silva AR; Gruetter R; Jelescu IO
J Magn Reson; 2019 Aug; 305():31-40. PubMed ID: 31195214
[TBL] [Abstract][Full Text] [Related]
12. Multiline balanced SSFP for rapid functional imaging at ultrahigh field.
Ehses P; Scheffler K
Magn Reson Med; 2018 Feb; 79(2):994-1000. PubMed ID: 28547846
[TBL] [Abstract][Full Text] [Related]
13. Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging.
Posse S; Ackley E; Mutihac R; Rick J; Shane M; Murray-Krezan C; Zaitsev M; Speck O
Neuroimage; 2012 May; 61(1):115-30. PubMed ID: 22398395
[TBL] [Abstract][Full Text] [Related]
14. High-resolution FMRI at 1.5T using balanced SSFP.
Miller KL; Smith SM; Jezzard P; Pauly JM
Magn Reson Med; 2006 Jan; 55(1):161-70. PubMed ID: 16345040
[TBL] [Abstract][Full Text] [Related]
15. Three-dimensional functional MRI with parallel acceleration: balanced SSFP versus PRESTO.
Vallée E; Håberg AK; Kristoffersen A
J Magn Reson Imaging; 2014 Mar; 39(3):656-64. PubMed ID: 23720400
[TBL] [Abstract][Full Text] [Related]
16. Effect of echo spacing and readout bandwidth on basic performances of EPI-fMRI acquisition sequences implemented on two 1.5 T MR scanner systems.
Giannelli M; Diciotti S; Tessa C; Mascalchi M
Med Phys; 2010 Jan; 37(1):303-10. PubMed ID: 20175493
[TBL] [Abstract][Full Text] [Related]
17. BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI.
Bhavsar S; Zvyagintsev M; Mathiak K
Neuroimage; 2014 Jan; 84():65-75. PubMed ID: 23954488
[TBL] [Abstract][Full Text] [Related]
18. Whole-head rapid fMRI acquisition using echo-shifted magnetic resonance inverse imaging.
Chang WT; Nummenmaa A; Witzel T; Ahveninen J; Huang S; Tsai KW; Chu YH; Polimeni JR; Belliveau JW; Lin FH
Neuroimage; 2013 Sep; 78():325-38. PubMed ID: 23563228
[TBL] [Abstract][Full Text] [Related]
19. Concurrent electrophysiological and hemodynamic measurements of evoked neural oscillations in human visual cortex using sparsely interleaved fast fMRI and EEG.
Lee HJ; Huang SY; Kuo WJ; Graham SJ; Chu YH; Stenroos M; Lin FH
Neuroimage; 2020 Aug; 217():116910. PubMed ID: 32389729
[TBL] [Abstract][Full Text] [Related]
20. Spatial sensitivity and temporal response of spin echo and gradient echo bold contrast at 3 T using peak hemodynamic activation time.
Hulvershorn J; Bloy L; Gualtieri EE; Leigh JS; Elliott MA
Neuroimage; 2005 Jan; 24(1):216-23. PubMed ID: 15588613
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]