BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

2765 related articles for article (PubMed ID: 27585995)

  • 1. Quantitative O-glycomics based on improvement of the one-pot method for nonreductive O-glycan release and simultaneous stable isotope labeling with 1-(d
    Wang C; Zhang P; Jin W; Li L; Qiang S; Zhang Y; Huang L; Wang Z
    J Proteomics; 2017 Jan; 150():18-30. PubMed ID: 27585995
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Separation of one-pot procedure released O-glycans as 1-phenyl-3-methyl-5-pyrazolone derivatives by hydrophilic interaction and reversed-phase liquid chromatography followed by identification using electrospray mass spectrometry and tandem mass spectrometry.
    Wang C; Yuan J; Wang Z; Huang L
    J Chromatogr A; 2013 Jan; 1274():107-17. PubMed ID: 23274074
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous Release and Labeling of O- and N-Glycans Allowing for Rapid Glycomic Analysis by Online LC-UV-ESI-MS/MS.
    Wang C; Lu Y; Han J; Jin W; Li L; Zhang Y; Song X; Huang L; Wang Z
    J Proteome Res; 2018 Jul; 17(7):2345-2357. PubMed ID: 29775069
    [TBL] [Abstract][Full Text] [Related]  

  • 4. One-pot nonreductive O-glycan release and labeling with 1-phenyl-3-methyl-5-pyrazolone followed by ESI-MS analysis.
    Wang C; Fan W; Zhang P; Wang Z; Huang L
    Proteomics; 2011 Nov; 11(21):4229-42. PubMed ID: 21956845
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative fingerprinting of O-linked glycans released from proteins using isotopic coded labeling with deuterated 1-phenyl-3-methyl-5-pyrazolone.
    Sić S; Maier NM; Rizzi AM
    J Chromatogr A; 2015 Aug; 1408():93-100. PubMed ID: 26184710
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel, simplified strategy of relative quantification N-glycan: Quantitative glycomics using electrospray ionization mass spectrometry through the stable isotopic labeling by transglycosylation reaction of mutant enzyme Endo-M-N175Q.
    Shi Q; Hashimoto R; Otsubo T; Ikeda K; Todoroki K; Mizuno H; Jin D; Toyo'oka T; Jiang Z; Min JZ
    J Pharm Biomed Anal; 2018 Feb; 149():365-373. PubMed ID: 29145098
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative profiling of O-glycans by electrospray ionization- and matrix-assisted laser desorption ionization-time-of-flight-mass spectrometry after in-gel derivatization with isotope-coded 1-phenyl-3-methyl-5-pyrazolone.
    Sić S; Maier NM; Rizzi AM
    Anal Chim Acta; 2016 Sep; 935():187-96. PubMed ID: 27543027
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relative quantitation of glycans using stable isotopic labels 1-(d0/d5) phenyl-3-methyl-5-pyrazolone by mass spectrometry.
    Zhang P; Zhang Y; Xue X; Wang C; Wang Z; Huang L
    Anal Biochem; 2011 Nov; 418(1):1-9. PubMed ID: 21803021
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simplified quantitative glycomics using the stable isotope label Girard's reagent p by electrospray ionization mass spectrometry.
    Wang C; Wu Z; Yuan J; Wang B; Zhang P; Zhang Y; Wang Z; Huang L
    J Proteome Res; 2014 Feb; 13(2):372-84. PubMed ID: 24274809
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nonreductive chemical release of intact N-glycans for subsequent labeling and analysis by mass spectrometry.
    Yuan J; Wang C; Sun Y; Huang L; Wang Z
    Anal Biochem; 2014 Oct; 462():1-9. PubMed ID: 24912132
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reductive chemical release of N-glycans as 1-amino-alditols and subsequent 9-fluorenylmethyloxycarbonyl labeling for MS and LC/MS analysis.
    Wang C; Qiang S; Jin W; Song X; Zhang Y; Huang L; Wang Z
    J Proteomics; 2018 Sep; 187():47-58. PubMed ID: 29885470
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relative quantitation of neutral and sialylated N-glycans using stable isotopic labeled d0/d5-benzoyl chloride by MALDI-MS.
    Wang C; Wu Y; Zhang L; Liu BF; Lin Y; Liu X
    Anal Chim Acta; 2018 Mar; 1002():50-61. PubMed ID: 29306413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mass spectrometric O-glycan analysis after combined O-glycan release by beta-elimination and 1-phenyl-3-methyl-5-pyrazolone labeling.
    Zauner G; Koeleman CA; Deelder AM; Wuhrer M
    Biochim Biophys Acta; 2012 Sep; 1820(9):1420-8. PubMed ID: 21803123
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stable isotopic labeling-based quantitative targeted glycomics (i-QTaG).
    Kim KJ; Kim YW; Kim YG; Park HM; Jin JM; Hwan Kim Y; Yang YH; Kyu Lee J; Chung J; Lee SG; Saghatelian A
    Biotechnol Prog; 2015; 31(3):840-8. PubMed ID: 25832445
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-sensitivity quantification of glycosphingolipid glycans by ESI-MS utilizing ozonolysis-based release and isotopic Girard's reagent labeling.
    Wang C; Wen Y; Yang M; Huang L; Wang Z; Fan J
    Anal Biochem; 2019 Oct; 582():113355. PubMed ID: 31276651
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relative quantitation of glycans in cetuximab using ultra-high-performance liquid chromatography-high-resolution mass spectrometry by Pronase E digestion.
    Li XL; Han C; Luo M; Xiao S; Li J; Yu C; Cheng S; Jin Y; Han Y; Todoroki K; Shi Q; Min JZ
    J Chromatogr A; 2022 Aug; 1677():463302. PubMed ID: 35820231
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 8-plex LC-MS/MS Analysis of Permethylated
    Dong X; Peng W; Yu CY; Zhou S; Donohoo KB; Tang H; Mechref Y
    Anal Chem; 2019 Sep; 91(18):11794-11802. PubMed ID: 31356052
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Glycan reductive isotope labeling for quantitative glycomics.
    Xia B; Feasley CL; Sachdev GP; Smith DF; Cummings RD
    Anal Biochem; 2009 Apr; 387(2):162-70. PubMed ID: 19454239
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Metabolic labeling of glycans with isotopic glucose for quantitative glycomics in yeast.
    Kim JY; Joo WH; Shin DS; Lee YI; Teo CF; Lim JM
    Anal Biochem; 2021 May; 621():114152. PubMed ID: 33726981
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis.
    Giménez E; Balmaña M; Figueras J; Fort E; Bolós C; Sanz-Nebot V; Peracaula R; Rizzi A
    Anal Chim Acta; 2015 Mar; 866():59-68. PubMed ID: 25732693
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 139.