These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 27587150)

  • 1. A magnetically actuated cellular strain assessment tool for quantitative analysis of strain induced cellular reorientation and actin alignment.
    Khademolhosseini F; Liu CC; Lim CJ; Chiao M
    Rev Sci Instrum; 2016 Aug; 87(8):085004. PubMed ID: 27587150
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Specificity of endothelial cell reorientation in response to cyclic mechanical stretching.
    Wang JH; Goldschmidt-Clermont P; Wille J; Yin FC
    J Biomech; 2001 Dec; 34(12):1563-72. PubMed ID: 11716858
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cyclic tensile strain controls cell shape and directs actin stress fiber formation and focal adhesion alignment in spreading cells.
    Greiner AM; Chen H; Spatz JP; Kemkemer R
    PLoS One; 2013; 8(10):e77328. PubMed ID: 24204809
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reorientation dynamics and structural interdependencies of actin, microtubules and intermediate filaments upon cyclic stretch application.
    Zielinski A; Linnartz C; Pleschka C; Dreissen G; Springer R; Merkel R; Hoffmann B
    Cytoskeleton (Hoboken); 2018 Sep; 75(9):385-394. PubMed ID: 30176121
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Actin stress fiber dynamics in laterally confined cells.
    Müller A; Müller S; Nasufovic V; Arndt HD; Pompe T
    Integr Biol (Camb); 2019 May; 11(5):175-185. PubMed ID: 31297541
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Shearing-Stretching Device That Can Apply Physiological Fluid Shear Stress and Cyclic Stretch Concurrently to Endothelial Cells.
    Meza D; Abejar L; Rubenstein DA; Yin W
    J Biomech Eng; 2016 Mar; 138(3):4032550. PubMed ID: 26810848
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Contribution of actin filaments to the global compressive properties of fibroblasts.
    Ujihara Y; Nakamura M; Miyazaki H; Wada S
    J Mech Behav Biomed Mater; 2012 Oct; 14():192-8. PubMed ID: 23026698
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cyclic stress at mHz frequencies aligns fibroblasts in direction of zero strain.
    Faust U; Hampe N; Rubner W; Kirchgessner N; Safran S; Hoffmann B; Merkel R
    PLoS One; 2011; 6(12):e28963. PubMed ID: 22194961
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetically actuated microstructured surfaces can actively modify cell migration behaviour.
    Khademolhosseini F; Liu CC; Lim CJ; Chiao M
    Biomed Microdevices; 2016 Feb; 18(1):13. PubMed ID: 26825323
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical force mobilizes zyxin from focal adhesions to actin filaments and regulates cytoskeletal reinforcement.
    Yoshigi M; Hoffman LM; Jensen CC; Yost HJ; Beckerle MC
    J Cell Biol; 2005 Oct; 171(2):209-15. PubMed ID: 16247023
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Structural alteration of the endothelial glycocalyx: contribution of the actin cytoskeleton.
    Li W; Wang W
    Biomech Model Mechanobiol; 2018 Feb; 17(1):147-158. PubMed ID: 28808796
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A mathematical model of cell reorientation in response to substrate stretching.
    Lazopoulos KA; Stamenović D
    Mol Cell Biomech; 2006 Mar; 3(1):43-8. PubMed ID: 16711071
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cellular strain assessment tool (CSAT): precision-controlled cyclic uniaxial tensile loading.
    Yung YC; Vandenburgh H; Mooney DJ
    J Biomech; 2009 Jan; 42(2):178-82. PubMed ID: 19121524
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Unbiased pattern analysis reveals highly diverse responses of cytoskeletal systems to cyclic straining.
    Springer R; Zielinski A; Pleschka C; Hoffmann B; Merkel R
    PLoS One; 2019; 14(3):e0210570. PubMed ID: 30865622
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Drebrin preserves endothelial integrity by stabilizing nectin at adherens junctions.
    Rehm K; Panzer L; van Vliet V; Genot E; Linder S
    J Cell Sci; 2013 Aug; 126(Pt 16):3756-69. PubMed ID: 23750010
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Time-dependent modulation of alignment and differentiation of smooth muscle cells seeded on a porous substrate undergoing cyclic mechanical strain.
    Cha JM; Park SN; Noh SH; Suh H
    Artif Organs; 2006 Apr; 30(4):250-8. PubMed ID: 16643383
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Strain waveform dependence of stress fiber reorientation in cyclically stretched osteoblastic cells: effects of viscoelastic compression of stress fibers.
    Nagayama K; Kimura Y; Makino N; Matsumoto T
    Am J Physiol Cell Physiol; 2012 May; 302(10):C1469-78. PubMed ID: 22357736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cellular strain avoidance is mediated by a functional actin cap - observations in an
    Tamiello C; Halder M; Kamps MA; Baaijens FP; Broers JL; Bouten CV
    J Cell Sci; 2017 Feb; 130(4):779-790. PubMed ID: 28062850
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Temporal responses of human endothelial and smooth muscle cells exposed to uniaxial cyclic tensile strain.
    Greiner AM; Biela SA; Chen H; Spatz JP; Kemkemer R
    Exp Biol Med (Maywood); 2015 Oct; 240(10):1298-309. PubMed ID: 25687334
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Role of nesprin-1 in nuclear deformation in endothelial cells under static and uniaxial stretching conditions.
    Anno T; Sakamoto N; Sato M
    Biochem Biophys Res Commun; 2012 Jul; 424(1):94-9. PubMed ID: 22728879
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.