194 related articles for article (PubMed ID: 27589225)
1. Continuous CD34+ cell collection by a new device is safe and more efficient than by a standard collection procedure: results of a two-center, crossover, randomized trial.
Cancelas JA; Scott EP; Bill JR
Transfusion; 2016 Nov; 56(11):2824-2832. PubMed ID: 27589225
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of the Spectra Optia apheresis system for mononuclear cell (MNC) collection in G-CSF mobilized and nonmobilized healthy donors: results of a multicenter study.
Karafin MS; Graminske S; Erickson P; Walters MC; Scott EP; Carter S; Padmanabhan A
J Clin Apher; 2014 Oct; 29(5):273-80. PubMed ID: 24677347
[TBL] [Abstract][Full Text] [Related]
3. Optia® continuous mononuclear collection (CMNC) system is a safe and efficient system for hematopoietic progenitor cells-apheresis (HPC-a) collection and yields a lower product hematocrit (HCT%) than the COBE® spectra system: A retrospective study.
Pandey S; Cottler-Fox M
J Clin Apher; 2018 Aug; 33(4):505-513. PubMed ID: 29603795
[TBL] [Abstract][Full Text] [Related]
4. Allogeneic donor peripheral blood "stem cell" apheresis: prospective comparison of two apheresis systems.
Brauninger S; Bialleck H; Thorausch K; Felt T; Seifried E; Bonig H
Transfusion; 2012 May; 52(5):1137-45. PubMed ID: 22044384
[TBL] [Abstract][Full Text] [Related]
5. [Effect of Different Procedures from Blood Cell Separators on Autologous PBSC Collection Efficiency].
Wang XN; Yao JN; Liu F; Wang XJ; Ma JJ; Guo CL; Liu HS; He PC; Zhang M; Sun CH
Zhongguo Shi Yan Xue Ye Xue Za Zhi; 2016 Oct; 24(5):1529-1532. PubMed ID: 27784387
[TBL] [Abstract][Full Text] [Related]
6. Spectra Optia granulocyte apheresis collections result in higher collection efficiency of viable, functional neutrophils in a randomized, crossover, multicenter trial.
Cancelas JA; Padmanabhan A; Le T; Ambruso DR; Rugg N; Worsham DN; Pinkard SL; Graminske S; Buck J; Goldberg J; Bill J
Transfusion; 2015 Apr; 55(4):748-55. PubMed ID: 25382805
[TBL] [Abstract][Full Text] [Related]
7. Peripheral blood stem cells collection on spectra optia apheresis system using the continuous mononuclear cell collection protocol: A single center report of 39 procedures.
Sanderson F; Poullin P; Smith R; Nicolino-Brunet C; Philip P; Chaib A; Costello R
J Clin Apher; 2017 Jun; 32(3):182-190. PubMed ID: 27442837
[TBL] [Abstract][Full Text] [Related]
8. Comparison between intermittent and continuous leukapheresis protocols for autologous hematopoietic stem cell collections in children.
Ali S; Chiang KY; Even-Or E; Di Mola M; Schechter T; Ali M; McDougall E; Svajger G; Licht C; Krueger J
J Clin Apher; 2019 Dec; 34(6):646-655. PubMed ID: 31424127
[TBL] [Abstract][Full Text] [Related]
9. Granulocyte collection using a novel apheresis system eases the procedure and provides concentrates of high quality.
Leitner GC; Kolovratova V; Horvath M; Worel N
Transfusion; 2015 May; 55(5):991-5. PubMed ID: 25412946
[TBL] [Abstract][Full Text] [Related]
10. Prospective randomized and crossover comparison of two apheresis machines for peripheral blood stem cell collection: a multicenter study.
Ikeda K; Minakawa K; Muroi K; Fujiwara SI; Yamada-Fujiwara M; Fujimori Y; Tanosaki R; Ohto H;
Transfusion; 2016 Nov; 56(11):2839-2847. PubMed ID: 27572290
[TBL] [Abstract][Full Text] [Related]
11. Evolution of MNC and lymphocyte collection settings employing different Spectra Optia
Punzel M; Kozlova A; Quade A; Schmidt AH; Smith R
Vox Sang; 2017 Aug; 112(6):586-594. PubMed ID: 28809049
[TBL] [Abstract][Full Text] [Related]
12. Comparison between intermittent and continuous spectra optia leukapheresis systems for autologous peripheral blood stem cell collection.
Lisenko K; Pavel P; Bruckner T; Puthenparambil J; Hundemer M; Schmitt A; Witzens-Harig M; Ho AD; Wuchter P
J Clin Apher; 2017 Feb; 32(1):27-34. PubMed ID: 27095367
[TBL] [Abstract][Full Text] [Related]
13. Automated collection of peripheral blood stem cells with the COBE spectra for autotransplantation.
Heuft HG; Dubiel M; Kingreen D; Oertel J; De Reys S; Rick O; Serke S; Schwella N
Vox Sang; 2000; 79(2):94-9. PubMed ID: 11054047
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of the new continuous mononuclear cell collection protocol versus an older version on two different apheresis machines.
Spoerl S; Wäscher D; Nagel S; Peschel C; Verbeek M; Götze K; Krackhardt AM
Transfusion; 2018 Jul; 58(7):1772-1780. PubMed ID: 29732573
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the spectra Optia® mononuclear cell collection procedure in multiple myeloma patients.
Long G; Waller EK; Gregurek S; Tricot G; Marschner S; Bill J
J Clin Apher; 2015 Feb; 30(1):1-7. PubMed ID: 24941931
[TBL] [Abstract][Full Text] [Related]
16. Mobilized allogeneic peripheral stem/progenitor cell apheresis with Spectra Optia v.5·0, a novel, automatic interface-controlled apheresis system: results from the first feasibility trial.
Brauninger S; Bialleck H; Thorausch K; Seifried E; Bonig H
Vox Sang; 2011 Oct; 101(3):237-46. PubMed ID: 21517897
[TBL] [Abstract][Full Text] [Related]
17. Evaluating the efficiency and safety of large-volume leukapheresis using the Spectra Optia continuous mononuclear cell collection protocol for peripheral blood stem cell collection from healthy donors: A retrospective study.
Sumii Y; Fujii K; Kondo T; Urata T; Kimura M; Fujiwara H; Asada N; Ennishi D; Nishimori H; Matsuoka KI; Otsuka F; Maeda Y; Fujii N
Transfusion; 2023 Nov; 63(11):2120-2130. PubMed ID: 37792312
[TBL] [Abstract][Full Text] [Related]
18. Clinical impact of a new automated system employed for peripheral blood stem cell collection.
Del Fante C; Perotti C; Viarengo G; Bellotti L; Parisi C; Marchesi A; Tinelli C; Salvaneschi L
J Clin Apher; 2006 Dec; 21(4):227-32. PubMed ID: 16847939
[TBL] [Abstract][Full Text] [Related]
19. A prospective randomized trial of two popular mononuclear cell collection sets for autologous peripheral blood stem cell collection in multiple myeloma.
Cooling L; Hoffmann S; Herrst M; Muck C; Armelagos H; Davenport R
Transfusion; 2010 Jan; 50(1):100-19. PubMed ID: 19719472
[TBL] [Abstract][Full Text] [Related]
20. Retrospective comparison between COBE SPECTRA and SPECTRA OPTIA apheresis systems for hematopoietic progenitor cells collection for autologous and allogeneic transplantation in a single center.
López-Pereira P; Sola Aparicio E; Vicuña Andrés I; Cámara Montejano C; Muñoz Calleja C; Alegre Amor A; Aguado Bueno B
J Clin Apher; 2020 Sep; 35(5):453-459. PubMed ID: 32798328
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]