156 related articles for article (PubMed ID: 27596344)
1. [Influence of trabecular microstructure modeling on finite element analysis of dental implant].
Shen MJ; Wang GG; Zhu XH; Ding X
Zhonghua Kou Qiang Yi Xue Za Zhi; 2016 Sep; 51(9):542-5. PubMed ID: 27596344
[TBL] [Abstract][Full Text] [Related]
2. Influence of Trabecular Bone on Peri-Implant Stress and Strain Based on Micro-CT Finite Element Modeling of Beagle Dog.
Liao SH; Zhu XH; Xie J; Sohodeb VK; Ding X
Biomed Res Int; 2016; 2016():3926941. PubMed ID: 27403424
[TBL] [Abstract][Full Text] [Related]
3. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
[TBL] [Abstract][Full Text] [Related]
4. The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis.
Robau-Porrua A; Pérez-Rodríguez Y; Soris-Rodríguez LM; Pérez-Acosta O; González JE
Biomed Mater Eng; 2020; 30(5-6):541-558. PubMed ID: 31903978
[TBL] [Abstract][Full Text] [Related]
5. [Three dimensional finite element analysis of biomechanical distribution of dental implants with immediate loading].
Han XL; Liu ZW; Li YT
Hua Xi Kou Qiang Yi Xue Za Zhi; 2011 Apr; 29(2):121-4. PubMed ID: 21598477
[TBL] [Abstract][Full Text] [Related]
6. Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.
Kan B; Coskunses FM; Mutlu I; Ugur L; Meral DG
Int J Oral Maxillofac Surg; 2015 Jul; 44(7):908-13. PubMed ID: 25818310
[TBL] [Abstract][Full Text] [Related]
7. Stress analysis at bone-implant interface of single- and two-implant-retained mandibular overdenture using three-dimensional finite element analysis.
Lahoti K; Pathrabe A; Gade J
Indian J Dent Res; 2016; 27(6):597-601. PubMed ID: 28169256
[TBL] [Abstract][Full Text] [Related]
8. Trabecular bone strains around a dental implant and associated micromotions--a micro-CT-based three-dimensional finite element study.
Limbert G; van Lierde C; Muraru OL; Walboomers XF; Frank M; Hansson S; Middleton J; Jaecques S
J Biomech; 2010 May; 43(7):1251-61. PubMed ID: 20170921
[TBL] [Abstract][Full Text] [Related]
9. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.
Bulaqi HA; Mousavi Mashhadi M; Safari H; Samandari MM; Geramipanah F
J Prosthet Dent; 2015 Jun; 113(6):548-57. PubMed ID: 25794917
[TBL] [Abstract][Full Text] [Related]
10. Three-Dimensional Nonlinear Contact Finite Element Analysis of Mandibular All-on-4 Design.
Hussein MO; Rabie ME
J Oral Implantol; 2015 Apr; 41(2):e12-8. PubMed ID: 24032471
[TBL] [Abstract][Full Text] [Related]
11. Comparison of the effects of different implant apical designs on the magnitude and distribution of stress and strain in bone: a finite element analysis study.
Kadkhodazadeh M; Lafzi A; Raoofi S; Khademi M; Amid R; Movahhedy MR; Torabi H
J Long Term Eff Med Implants; 2014; 24(2-3):109-19. PubMed ID: 25272209
[TBL] [Abstract][Full Text] [Related]
12. Effect of surface treatment on stress distribution in immediately loaded dental implants--a 3D finite element analysis.
Bahrami B; Shahrbaf S; Mirzakouchaki B; Ghalichi F; Ashtiani M; Martin N
Dent Mater; 2014 Apr; 30(4):e89-97. PubMed ID: 24559526
[TBL] [Abstract][Full Text] [Related]
13. [Establishment of a three-dimensional finite element model of mandible with dental implants for immediate loading].
Ding X; Zhu XH; Liao SH; Tong RF; Fang YM; Zhang L
Shanghai Kou Qiang Yi Xue; 2006 Aug; 15(4):391-4. PubMed ID: 16955165
[TBL] [Abstract][Full Text] [Related]
14. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis.
Frisardi G; Barone S; Razionale AV; Paoli A; Frisardi F; Tullio A; Lumbau A; Chessa G
Head Face Med; 2012 May; 8():18. PubMed ID: 22642768
[TBL] [Abstract][Full Text] [Related]
15. Stress analysis in simulation models with or without implant threads representation.
Assunção WG; Gomes EA; Barão VA; de Sousa EA
Int J Oral Maxillofac Implants; 2009; 24(6):1040-4. PubMed ID: 20162107
[TBL] [Abstract][Full Text] [Related]
16. Regular and platform switching: bone stress analysis varying implant type.
Gurgel-Juarez NC; de Almeida EO; Rocha EP; Freitas AC; Anchieta RB; de Vargas LC; Kina S; França FM
J Prosthodont; 2012 Apr; 21(3):160-6. PubMed ID: 22372756
[TBL] [Abstract][Full Text] [Related]
17. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant.
Hudieb MI; Wakabayashi N; Kasugai S
J Periodontol; 2011 Jul; 82(7):1061-70. PubMed ID: 21189091
[TBL] [Abstract][Full Text] [Related]
18. Finite element analysis of dental implant loading on atrophic and non-atrophic cancellous and cortical mandibular bone - a feasibility study.
Marcián P; Borák L; Valášek J; Kaiser J; Florian Z; Wolff J
J Biomech; 2014 Dec; 47(16):3830-6. PubMed ID: 25468296
[TBL] [Abstract][Full Text] [Related]
19. The biomechanical analysis of simulating implants in function under osteoporotic jawbone by comparing cylindrical, apical tapered, neck tapered, and expandable type implants: a 3-dimensional finite element analysis.
Xiao JR; Li YF; Guan SM; Song L; Xu LX; Kong L
J Oral Maxillofac Surg; 2011 Jul; 69(7):e273-81. PubMed ID: 21367505
[TBL] [Abstract][Full Text] [Related]
20. [Three dimension finite element analysis of anisotropic mandible with dental implants effect on implant-bone interface].
Ding X; Zhu XH; Zhang XH; Liao SH; Zhang-Lin ; Chen H
Zhonghua Kou Qiang Yi Xue Za Zhi; 2009 Jan; 44(1):41-5. PubMed ID: 19489259
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]