1. Theoretical quantification of the effects of plastic wall thickness on phantom measurements in electromagnetic hyperthermia. Ross MP; Paulsen KD IEEE Trans Biomed Eng; 1989 Aug; 36(8):869-72. PubMed ID: 2759648 [TBL] [Abstract][Full Text] [Related]
2. The polyacrylamide as a phantom material for electromagnetic hyperthermia studies. Bini MG; Ignesti A; Millanta L; Olmi R; Rubino N; Vanni R IEEE Trans Biomed Eng; 1984 Mar; 31(3):317-22. PubMed ID: 6715003 [No Abstract] [Full Text] [Related]
3. A water-cooled EM applicator radiating in a phantom equivalent tissue--experiments and numerical analysis. Gentili GB; Gori F; Lachi L; Leoncini M IEEE Trans Biomed Eng; 1991 Sep; 38(9):924-8. PubMed ID: 1743741 [TBL] [Abstract][Full Text] [Related]
4. Fabrication and analysis of plastic hypodermic needles. Kim H; Colton JS J Med Eng Technol; 2005; 29(4):181-6. PubMed ID: 16012070 [TBL] [Abstract][Full Text] [Related]
5. A quasi-static model for the ring capacitor applicator. Sowiński MJ; van Putten MH; van den Berg PM; van Rhoon GC IEEE Trans Biomed Eng; 1989 Oct; 36(10):995-1003. PubMed ID: 2793200 [TBL] [Abstract][Full Text] [Related]
6. Measurement of the thermal conductivity of polyacrylamide tissue-equivalent material. Davidson SR; Sherar MD Int J Hyperthermia; 2003; 19(5):551-62. PubMed ID: 12944169 [TBL] [Abstract][Full Text] [Related]
7. Theoretical electric field distributions produced by three types of regional hyperthermia devices in a three-dimensional homogeneous model of man. Paulsen KD; Strohbehn JW; Lynch DR IEEE Trans Biomed Eng; 1988 Jan; 35(1):36-45. PubMed ID: 3338810 [No Abstract] [Full Text] [Related]
8. Design of a UHF applicator for rewarming of cryopreserved biomaterials. Evans S; Rachman MJ; Pegg DE IEEE Trans Biomed Eng; 1992 Mar; 39(3):217-25. PubMed ID: 1555851 [TBL] [Abstract][Full Text] [Related]
9. [Measures of specific absorption rate (SAR) in microwave hyperthermic oncology and the influence of the dynamic bolus on clinical practice]. Marini P; Guiot C; Baiotto B; Gabriele P Radiol Med; 2001 Sep; 102(3):159-67. PubMed ID: 11677459 [TBL] [Abstract][Full Text] [Related]
11. The influence of artificial sealing on the capillary barrier's function. Trpkosová D; Mls J Waste Manag; 2010 Jan; 30(1):125-31. PubMed ID: 19853432 [TBL] [Abstract][Full Text] [Related]
12. Mathematical model of a double-coil inductive transducer for measuring electrical conductivity. Kusmierz J Rev Sci Instrum; 2007 Aug; 78(8):084704. PubMed ID: 17764344 [TBL] [Abstract][Full Text] [Related]
13. Toroidal coil models for transcutaneous magnetic stimulation of nerves. Carbunaru R; Durand DM IEEE Trans Biomed Eng; 2001 Apr; 48(4):434-41. PubMed ID: 11322531 [TBL] [Abstract][Full Text] [Related]
14. Design optimization of interstitial antennas. Iskander MF; Tumeh AM IEEE Trans Biomed Eng; 1989 Feb; 36(2):238-46. PubMed ID: 2917769 [TBL] [Abstract][Full Text] [Related]
15. Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method. de Bruijne M; Samaras T; Chavannes N; van Rhoon GC Phys Med Biol; 2007 Jun; 52(11):3075-88. PubMed ID: 17505090 [TBL] [Abstract][Full Text] [Related]
16. Influence of pixel size on quantification of airway wall thickness in computed tomography. Achenbach T; Weinheimer O; Dueber C; Heussel CP J Comput Assist Tomogr; 2009; 33(5):725-30. PubMed ID: 19820501 [TBL] [Abstract][Full Text] [Related]
17. [Anisotropic electric conductivity of bacterial suspensions induced by external electric field]. Voĭtylov VV; Kakorin SA; Trusov AA Biofizika; 1990; 35(4):634-6. PubMed ID: 2245228 [TBL] [Abstract][Full Text] [Related]
18. Design criterions for active shielding of inhomogeneous magnetic fields for biomagnetic applications. Urankar L; Oppelt R IEEE Trans Biomed Eng; 1996 Jul; 43(7):697-707. PubMed ID: 9216141 [TBL] [Abstract][Full Text] [Related]
19. An edge-element based finite element model of microwave heating in hyperthermia: method and verification. Kumaradas JC; Sherar MD Int J Hyperthermia; 2002; 18(5):426-40. PubMed ID: 12227929 [TBL] [Abstract][Full Text] [Related]
20. A 3-D SAR model for current source interstitial hyperthermia. de Bree J; van der Koijk JF; Lagendijk JJ IEEE Trans Biomed Eng; 1996 Oct; 43(10):1038-45. PubMed ID: 9214821 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]