BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 2760330)

  • 1. [A symmetry approach to electrocardiogram analysis].
    Dmitrieva NV
    Izv Akad Nauk SSSR Biol; 1989; (3):450-7. PubMed ID: 2760330
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Subject-specific heart rate dependency of electrocardiographic QT, PQ, and QRS intervals.
    Malik M; Hnatkova K; Sisakova M; Schmidt G
    J Electrocardiol; 2008; 41(6):491-7. PubMed ID: 18817925
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The electrocardiogram of the Beagle dog: reference values and effect of sex, genetic strain, body position and heart rate.
    Hanton G; Rabemampianina Y
    Lab Anim; 2006 Apr; 40(2):123-36. PubMed ID: 16600072
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A dynamical model for generating synthetic electrocardiogram signals.
    McSharry PE; Clifford GD; Tarassenko L; Smith LA
    IEEE Trans Biomed Eng; 2003 Mar; 50(3):289-94. PubMed ID: 12669985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Study of repolarization heterogeneity and electrocardiographic morphology with a modeling approach.
    Xue J; Gao W; Chen Y; Han X
    J Electrocardiol; 2008; 41(6):581-7. PubMed ID: 18804785
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Localization of the site of origin of cardiac activation by means of a heart-model-based electrocardiographic imaging approach.
    Li G; He B
    IEEE Trans Biomed Eng; 2001 Jun; 48(6):660-9. PubMed ID: 11396596
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The influence of carbamazepine plasma level on blood pressure and some ECG parameters in patients with acute intoxication.
    Ciszowski K; Szpak D; Jenner B
    Przegl Lek; 2007; 64(4-5):248-51. PubMed ID: 17724878
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling QRS complex in dECG.
    Kamath C; Ananthapadmanabha TV
    IEEE Trans Biomed Eng; 2007 Jan; 54(1):156-8. PubMed ID: 17260867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sample size, power calculations, and their implications for the cost of thorough studies of drug induced QT interval prolongation.
    Malik M; Hnatkova K; Batchvarov V; Gang Y; Smetana P; Camm AJ
    Pacing Clin Electrophysiol; 2004 Dec; 27(12):1659-69. PubMed ID: 15613131
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of ECG indices of ventricular repolarization heterogeneity: a computer simulation study.
    Van Huysduynen BH; Swenne CA; Draisma HH; Antoni ML; Van De Vooren H; Van Der Wall EE; Schalij MJ
    J Cardiovasc Electrophysiol; 2005 Oct; 16(10):1097-103. PubMed ID: 16191120
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The U wave in the electrocardiogram: a solution for a 100-year-old riddle.
    Ritsema van Eck HJ; Kors JA; van Herpen G
    Cardiovasc Res; 2005 Aug; 67(2):256-62. PubMed ID: 15913583
    [TBL] [Abstract][Full Text] [Related]  

  • 12. QT analysis: a complex answer to a 'simple' problem.
    Li L; Desai M; Desta Z; Flockhart D
    Stat Med; 2004 Sep; 23(17):2625-43. PubMed ID: 15316947
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multiparametric electrocardiographic evaluation of left ventricular hypertrophy in idiopathic and hypertensive cardiomyopathy.
    Lazzeri C; Barletta G; Badia T; Capalbio A; Del Bene R; Franchi F; Gensini GF; Michelucci A
    Ital Heart J; 2005 Apr; 6(4):304-10. PubMed ID: 15902928
    [TBL] [Abstract][Full Text] [Related]  

  • 14. QT variability and HRV interactions in ECG: quantification and reliability.
    Almeida R; Gouveia S; Rocha AP; Pueyo E; MartĂ­nez JP; Laguna P
    IEEE Trans Biomed Eng; 2006 Jul; 53(7):1317-29. PubMed ID: 16830936
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Air pollution effects on ventricular repolarization.
    Lux RL; Pope CA
    Res Rep Health Eff Inst; 2009 May; (141):3-20; discussion 21-8. PubMed ID: 19579527
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Investigating the effect of sotalol on the repolarization intervals in healthy young individuals.
    Couderc JP; Zhou M; Sarapa N; Zareba W
    J Electrocardiol; 2008; 41(6):595-602. PubMed ID: 18801493
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computer simulation of fibrillation threshold measurements and electrophysiologic testing procedures.
    Grumbach MP; Saxberg BE; Cohen RJ
    Comput Cardiol; 1987; 13():449-52. PubMed ID: 11541829
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Simulation application of whole-heart electophysiological model].
    Zhu H; Yin B; Zhu D
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Mar; 20(1):86-90. PubMed ID: 12744171
    [TBL] [Abstract][Full Text] [Related]  

  • 19. QT interval variability and adaptation to heart rate changes in patients with long QT syndrome.
    Nemec J; Buncová M; Shusterman V; Winter B; Shen WK; Ackerman MJ
    Pacing Clin Electrophysiol; 2009 Jan; 32(1):72-81. PubMed ID: 19140916
    [TBL] [Abstract][Full Text] [Related]  

  • 20. T(p-e)/QT ratio as an index of arrhythmogenesis.
    Gupta P; Patel C; Patel H; Narayanaswamy S; Malhotra B; Green JT; Yan GX
    J Electrocardiol; 2008; 41(6):567-74. PubMed ID: 18790499
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.