These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
228 related articles for article (PubMed ID: 27604905)
1. Verification of in vivo accuracy of Trumatch™ patient-specific instrumentation in total knee replacement using pin-less computer navigation. Briffa N; Imam MA; Mallina R; Abdelkafy A; Adhikari A Eur J Orthop Surg Traumatol; 2017 Jan; 27(1):125-132. PubMed ID: 27604905 [TBL] [Abstract][Full Text] [Related]
2. Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation. Kerens B; Leenders AM; Schotanus MGM; Boonen B; Tuinebreijer WE; Emans PJ; Jong B; Kort NP Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1823-1830. PubMed ID: 29282486 [TBL] [Abstract][Full Text] [Related]
3. Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation. Scholes C; Sahni V; Lustig S; Parker DA; Coolican MR Knee Surg Sports Traumatol Arthrosc; 2014 Mar; 22(3):660-5. PubMed ID: 24042965 [TBL] [Abstract][Full Text] [Related]
4. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting. Suero EM; Lueke U; Stuebig T; Hawi N; Krettek C; Liodakis E Orthop Traumatol Surg Res; 2018 Nov; 104(7):971-975. PubMed ID: 29704634 [TBL] [Abstract][Full Text] [Related]
5. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial. Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560 [TBL] [Abstract][Full Text] [Related]
6. Do manual cutting guides for total knee arthroplasty introduce systematic error? Hohmann E; Tetsworth K Int Orthop; 2016 Feb; 40(2):277-84. PubMed ID: 26298536 [TBL] [Abstract][Full Text] [Related]
7. Component position alignment with patient-specific jigs in total knee arthroplasty. Moopanar TR; Amaranath JE; Sorial RM ANZ J Surg; 2014 Sep; 84(9):628-32. PubMed ID: 24946273 [TBL] [Abstract][Full Text] [Related]
8. Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. Lustig S; Scholes CJ; Oussedik SI; Kinzel V; Coolican MR; Parker DA J Arthroplasty; 2013 Mar; 28(3):469-73. PubMed ID: 23151366 [TBL] [Abstract][Full Text] [Related]
9. Navigated total knee arthroplasty: is it error-free? Chua KH; Chen Y; Lingaraj K Knee Surg Sports Traumatol Arthrosc; 2014 Mar; 22(3):643-9. PubMed ID: 24061715 [TBL] [Abstract][Full Text] [Related]
10. Patient-specific instrumentation for total knee replacement verified by computer navigation: a case report. Chan KY; Teo YH J Orthop Surg (Hong Kong); 2012 Apr; 20(1):111-4. PubMed ID: 22535825 [TBL] [Abstract][Full Text] [Related]
11. Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty. Catani F; Biasca N; Ensini A; Leardini A; Bianchi L; Digennaro V; Giannini S J Bone Joint Surg Am; 2008 Apr; 90(4):765-71. PubMed ID: 18381314 [TBL] [Abstract][Full Text] [Related]
12. Does Patient-Specific Instrumentation Improve Femoral and Tibial Component Alignment in Total Knee Arthroplasty? A Prospective Randomized Study. Stolarczyk A; Nagraba L; Mitek T; Stolarczyk M; Deszczyński JM; Jakucinski M Adv Exp Med Biol; 2018; 1096():11-17. PubMed ID: 29623574 [TBL] [Abstract][Full Text] [Related]
13. Assessing the accuracy of patient-specific guides for total knee arthroplasty. Seon JK; Park HW; Yoo SH; Song EK Knee Surg Sports Traumatol Arthrosc; 2016 Nov; 24(11):3678-3683. PubMed ID: 25399345 [TBL] [Abstract][Full Text] [Related]
14. Accelerometer-Based and Computer-Assisted Navigation in Total Knee Arthroplasty: A Reduction in Mechanical Axis Outliers Does Not Lead to Improvement in Functional Outcomes or Quality of Life When Compared to Conventional Total Knee Arthroplasty. Goh GS; Liow MHL; Tay DK; Lo NN; Yeo SJ; Tan MH J Arthroplasty; 2018 Feb; 33(2):379-385. PubMed ID: 29054725 [TBL] [Abstract][Full Text] [Related]
15. Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes. Yamamura K; Minoda Y; Sugama R; Ohta Y; Nakamura S; Ueyama H; Nakamura H Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1560-1567. PubMed ID: 31240377 [TBL] [Abstract][Full Text] [Related]
16. Radiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty. Nam D; Cross M; Deshmane P; Jerabek S; Kang M; Mayman DJ Orthopedics; 2011 Oct; 34(10):e615-21. PubMed ID: 21956055 [TBL] [Abstract][Full Text] [Related]
17. Accuracy of a hand-held surgical navigation system for tibial resection in total knee arthroplasty. Bugbee WD; Kermanshahi AY; Munro MM; McCauley JC; Copp SN Knee; 2014 Dec; 21(6):1225-8. PubMed ID: 25311515 [TBL] [Abstract][Full Text] [Related]
18. Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis. Kievit AJ; Dobbe JGG; Streekstra GJ; Blankevoort L; Schafroth MU Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1751-1758. PubMed ID: 28948339 [TBL] [Abstract][Full Text] [Related]
19. A systematic review and meta-analysis of patient-specific instrumentation for improving alignment of the components in total knee replacement. Thienpont E; Schwab PE; Fennema P Bone Joint J; 2014 Aug; 96-B(8):1052-61. PubMed ID: 25086121 [TBL] [Abstract][Full Text] [Related]