These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

446 related articles for article (PubMed ID: 27612053)

  • 1. A new metal artifact reduction algorithm based on a deteriorated CT image.
    Kano T; Koseki M
    J Xray Sci Technol; 2016 Nov; 24(6):901-912. PubMed ID: 27612053
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A metal artifact reduction method for a dental CT based on adaptive local thresholding and prior image generation.
    Hegazy MA; Cho MH; Lee SY
    Biomed Eng Online; 2016 Nov; 15(1):119. PubMed ID: 27814775
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Metal artifact reduction in computed tomography using local models in an image block-iterative scheme.
    Van Slambrouck K; Nuyts J
    Med Phys; 2012 Nov; 39(11):7080-93. PubMed ID: 23127099
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Suppression of metal artifacts in CT using a reconstruction procedure that combines MAP and projection completion.
    Lemmens C; Faul D; Nuyts J
    IEEE Trans Med Imaging; 2009 Feb; 28(2):250-60. PubMed ID: 19188112
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new approach for reducing beam hardening artifacts in polychromatic X-ray computed tomography using more accurate prior image.
    Wang H; Xu Y; Shi H
    J Xray Sci Technol; 2018; 26(4):593-602. PubMed ID: 29562575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model.
    Fang J; Zhang D; Wilcox C; Heidinger B; Raptopoulos V; Brook A; Brook OR
    Abdom Radiol (NY); 2017 Mar; 42(3):742-748. PubMed ID: 28044188
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A CT metal artifact reduction algorithm based on sinogram surgery.
    Jeon S; Lee CO
    J Xray Sci Technol; 2018; 26(3):413-434. PubMed ID: 29562579
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A hybrid metal artifact reduction algorithm for x-ray CT.
    Zhang Y; Yan H; Jia X; Yang J; Jiang SB; Mou X
    Med Phys; 2013 Apr; 40(4):041910. PubMed ID: 23556904
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Segmentation of artifacts and anatomy in CT metal artifact reduction.
    Karimi S; Cosman P; Wald C; Martz H
    Med Phys; 2012 Oct; 39(10):5857-68. PubMed ID: 23039624
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic Value of Model-Based Iterative Reconstruction Combined with a Metal Artifact Reduction Algorithm during CT of the Oral Cavity.
    Kubo Y; Ito K; Sone M; Nagasawa H; Onishi Y; Umakoshi N; Hasegawa T; Akimoto T; Kusumoto M
    AJNR Am J Neuroradiol; 2020 Nov; 41(11):2132-2138. PubMed ID: 32972957
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Frequency split metal artifact reduction (FSMAR) in computed tomography.
    Meyer E; Raupach R; Lell M; Schmidt B; Kachelrieß M
    Med Phys; 2012 Apr; 39(4):1904-16. PubMed ID: 22482612
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of metal artifact reduction on the retrieval of attenuation values.
    Ziemann C; Stille M; Cremers F; Rades D; Buzug TM
    J Appl Clin Med Phys; 2017 Jan; 18(1):243-250. PubMed ID: 28291909
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gaussian diffusion sinogram inpainting for X-ray CT metal artifact reduction.
    Peng C; Qiu B; Li M; Guan Y; Zhang C; Wu Z; Zheng J
    Biomed Eng Online; 2017 Jan; 16(1):1. PubMed ID: 28086973
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improvement of dose calculation in radiation therapy due to metal artifact correction using the augmented likelihood image reconstruction.
    Ziemann C; Stille M; Cremers F; Buzug TM; Rades D
    J Appl Clin Med Phys; 2018 May; 19(3):227-233. PubMed ID: 29664225
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.
    Wuest W; May MS; Brand M; Bayerl N; Krauss A; Uder M; Lell M
    AJNR Am J Neuroradiol; 2015 Oct; 36(10):1988-93. PubMed ID: 26272971
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sequentially reweighted TV minimization for CT metal artifact reduction.
    Zhang X; Xing L
    Med Phys; 2013 Jul; 40(7):071907. PubMed ID: 23822444
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prior-based metal artifact reduction algorithm for x-ray CT.
    Li M; Zheng J; Zhang T; Guan Y; Xu P; Sun M
    J Xray Sci Technol; 2015; 23(2):229-41. PubMed ID: 25882733
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization.
    Zhang X; Wang J; Xing L
    Med Phys; 2011 Feb; 38(2):701-11. PubMed ID: 21452707
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Usefulness of a metal artifact reduction algorithm for orthopedic implants in abdominal CT: phantom and clinical study results.
    Jeong S; Kim SH; Hwang EJ; Shin CI; Han JK; Choi BI
    AJR Am J Roentgenol; 2015 Feb; 204(2):307-17. PubMed ID: 25615752
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Superiorized method for metal artifact reduction.
    Humphries T; Wang BJ
    Med Phys; 2020 Sep; 47(9):3984-3995. PubMed ID: 32542688
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.