BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

295 related articles for article (PubMed ID: 27612794)

  • 1. Wear studies on ZrO2-filled PEEK as coating bearing materials for artificial cervical discs of Ti6Al4V.
    Song J; Liu Y; Liao Z; Wang S; Tyagi R; Liu W
    Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():985-94. PubMed ID: 27612794
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications.
    Berni M; Lopomo N; Marchiori G; Gambardella A; Boi M; Bianchi M; Visani A; Pavan P; Russo A; Marcacci M
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():643-55. PubMed ID: 26952468
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
    Siskey R; Ciccarelli L; Lui MK; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of polyetheretherketone coatings on the Ti-13Nb-13Zr titanium alloy's bio-tribological properties and corrosion resistance.
    Sak A; Moskalewicz T; Zimowski S; Cieniek Ł; Dubiel B; Radziszewska A; Kot M; Łukaszczyk A
    Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():52-61. PubMed ID: 27040195
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wear studies on plasma-sprayed Al2O3 and 8mole% of Yttrium-stabilized ZrO2 composite coating on biomedical Ti-6Al-4V alloy for orthopedic joint application.
    Ganapathy P; Manivasagam G; Rajamanickam A; Natarajan A
    Int J Nanomedicine; 2015; 10 Suppl 1(Suppl 1):213-22. PubMed ID: 26491323
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An investigation into PEEK-on-PEEK as a bearing surface candidate for cervical total disc replacement.
    Kraft M; Koch DK; Bushelow M
    Spine J; 2012 Jul; 12(7):603-11. PubMed ID: 22964013
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Processing and evaluation of bioactive coatings on polymeric implants.
    Rabiei A; Sandukas S
    J Biomed Mater Res A; 2013 Sep; 101(9):2621-9. PubMed ID: 23412996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tribocorrosion behavior of veneering biomedical PEEK to Ti6Al4V structures.
    Sampaio M; Buciumeanu M; Henriques B; Silva FS; Souza JC; Gomes JR
    J Mech Behav Biomed Mater; 2016 Feb; 54():123-30. PubMed ID: 26454136
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison between PEEK and Ti6Al4V concerning micro-scale abrasion wear on dental applications.
    Sampaio M; Buciumeanu M; Henriques B; Silva FS; Souza JCM; Gomes JR
    J Mech Behav Biomed Mater; 2016 Jul; 60():212-219. PubMed ID: 26849309
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Study on improved tribological properties by alloying copper to CP-Ti and Ti-6Al-4V alloy.
    Wang S; Ma Z; Liao Z; Song J; Yang K; Liu W
    Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():123-32. PubMed ID: 26354247
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical and bioactive properties of PVD TiO
    Barhoumi N; Khlifi K; Attia-Essaies S
    J Mech Behav Biomed Mater; 2023 Aug; 144():105935. PubMed ID: 37290169
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of thick titanium plasma spray coatings on PEEK materials used for medical implants and the influence on the mechanical properties.
    Vogel D; Dempwolf H; Baumann A; Bader R
    J Mech Behav Biomed Mater; 2018 Jan; 77():600-608. PubMed ID: 29096126
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new material for hip prosthesis without considerable debris release.
    Borruto A
    Med Eng Phys; 2010 Oct; 32(8):908-13. PubMed ID: 20643571
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In Vivo Osseointegration Performance of Titanium Dioxide Coating Modified Polyetheretherketone Using Arc Ion Plating for Spinal Implant Application.
    Tsou HK; Chi MH; Hung YW; Chung CJ; He JL
    Biomed Res Int; 2015; 2015():328943. PubMed ID: 26504800
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination?
    Kienle A; Graf N; Wilke HJ
    Spine J; 2016 Feb; 16(2):235-42. PubMed ID: 26409208
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of intermediate ZrO2-CaO coatings deposited by cold thermal spraying on the titanium-porcelain bond in dental restorations.
    Marcelli E; Costantino ML; Villa T; Bagnoli P; Zannoli R; Corazza I; Cercenelli L
    J Prosthet Dent; 2014 Nov; 112(5):1201-11. PubMed ID: 24993377
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of working gas pressure on zirconium dioxide thin film prepared by pulsed plasma deposition: roughness, wettability, friction and wear characteristics.
    Berni M; Marchiori G; Gambardella A; Boi M; Bianchi M; Russo A; Visani A; Marcacci M; Pavan PG; Lopomo NF
    J Mech Behav Biomed Mater; 2017 Aug; 72():200-208. PubMed ID: 28500999
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multilayers of poly(ethyleneimine)/poly(acrylic acid) coatings on Ti6Al4V acting as lubricated polymer-bearing interface.
    Deng Y; Sun J; Ni X; Xiong D
    J Biomed Mater Res B Appl Biomater; 2020 Jul; 108(5):2141-2152. PubMed ID: 31904181
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimizing surface characteristics for cell adhesion and proliferation on titanium plasma spray coatings on polyetheretherketone.
    Yoon BJ; Xavier F; Walker BR; Grinberg S; Cammisa FP; Abjornson C
    Spine J; 2016 Oct; 16(10):1238-1243. PubMed ID: 27241209
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved biotribological properties of PEEK by photo-induced graft polymerization of acrylic acid.
    Zhao X; Xiong D; Wang K; Wang N
    Mater Sci Eng C Mater Biol Appl; 2017 Jun; 75():777-783. PubMed ID: 28415528
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.