295 related articles for article (PubMed ID: 27612794)
1. Wear studies on ZrO2-filled PEEK as coating bearing materials for artificial cervical discs of Ti6Al4V.
Song J; Liu Y; Liao Z; Wang S; Tyagi R; Liu W
Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():985-94. PubMed ID: 27612794
[TBL] [Abstract][Full Text] [Related]
2. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications.
Berni M; Lopomo N; Marchiori G; Gambardella A; Boi M; Bianchi M; Visani A; Pavan P; Russo A; Marcacci M
Mater Sci Eng C Mater Biol Appl; 2016 May; 62():643-55. PubMed ID: 26952468
[TBL] [Abstract][Full Text] [Related]
3. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
Siskey R; Ciccarelli L; Lui MK; Kurtz SM
Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
[TBL] [Abstract][Full Text] [Related]
4. Influence of polyetheretherketone coatings on the Ti-13Nb-13Zr titanium alloy's bio-tribological properties and corrosion resistance.
Sak A; Moskalewicz T; Zimowski S; Cieniek Ł; Dubiel B; Radziszewska A; Kot M; Łukaszczyk A
Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():52-61. PubMed ID: 27040195
[TBL] [Abstract][Full Text] [Related]
5. Wear studies on plasma-sprayed Al2O3 and 8mole% of Yttrium-stabilized ZrO2 composite coating on biomedical Ti-6Al-4V alloy for orthopedic joint application.
Ganapathy P; Manivasagam G; Rajamanickam A; Natarajan A
Int J Nanomedicine; 2015; 10 Suppl 1(Suppl 1):213-22. PubMed ID: 26491323
[TBL] [Abstract][Full Text] [Related]
6. An investigation into PEEK-on-PEEK as a bearing surface candidate for cervical total disc replacement.
Kraft M; Koch DK; Bushelow M
Spine J; 2012 Jul; 12(7):603-11. PubMed ID: 22964013
[TBL] [Abstract][Full Text] [Related]
7. Processing and evaluation of bioactive coatings on polymeric implants.
Rabiei A; Sandukas S
J Biomed Mater Res A; 2013 Sep; 101(9):2621-9. PubMed ID: 23412996
[TBL] [Abstract][Full Text] [Related]
8. Tribocorrosion behavior of veneering biomedical PEEK to Ti6Al4V structures.
Sampaio M; Buciumeanu M; Henriques B; Silva FS; Souza JC; Gomes JR
J Mech Behav Biomed Mater; 2016 Feb; 54():123-30. PubMed ID: 26454136
[TBL] [Abstract][Full Text] [Related]
9. Comparison between PEEK and Ti6Al4V concerning micro-scale abrasion wear on dental applications.
Sampaio M; Buciumeanu M; Henriques B; Silva FS; Souza JCM; Gomes JR
J Mech Behav Biomed Mater; 2016 Jul; 60():212-219. PubMed ID: 26849309
[TBL] [Abstract][Full Text] [Related]
10. Study on improved tribological properties by alloying copper to CP-Ti and Ti-6Al-4V alloy.
Wang S; Ma Z; Liao Z; Song J; Yang K; Liu W
Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():123-32. PubMed ID: 26354247
[TBL] [Abstract][Full Text] [Related]
11. Mechanical and bioactive properties of PVD TiO
Barhoumi N; Khlifi K; Attia-Essaies S
J Mech Behav Biomed Mater; 2023 Aug; 144():105935. PubMed ID: 37290169
[TBL] [Abstract][Full Text] [Related]
12. Characterization of thick titanium plasma spray coatings on PEEK materials used for medical implants and the influence on the mechanical properties.
Vogel D; Dempwolf H; Baumann A; Bader R
J Mech Behav Biomed Mater; 2018 Jan; 77():600-608. PubMed ID: 29096126
[TBL] [Abstract][Full Text] [Related]
13. A new material for hip prosthesis without considerable debris release.
Borruto A
Med Eng Phys; 2010 Oct; 32(8):908-13. PubMed ID: 20643571
[TBL] [Abstract][Full Text] [Related]
14. In Vivo Osseointegration Performance of Titanium Dioxide Coating Modified Polyetheretherketone Using Arc Ion Plating for Spinal Implant Application.
Tsou HK; Chi MH; Hung YW; Chung CJ; He JL
Biomed Res Int; 2015; 2015():328943. PubMed ID: 26504800
[TBL] [Abstract][Full Text] [Related]
15. Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination?
Kienle A; Graf N; Wilke HJ
Spine J; 2016 Feb; 16(2):235-42. PubMed ID: 26409208
[TBL] [Abstract][Full Text] [Related]
16. Effect of intermediate ZrO2-CaO coatings deposited by cold thermal spraying on the titanium-porcelain bond in dental restorations.
Marcelli E; Costantino ML; Villa T; Bagnoli P; Zannoli R; Corazza I; Cercenelli L
J Prosthet Dent; 2014 Nov; 112(5):1201-11. PubMed ID: 24993377
[TBL] [Abstract][Full Text] [Related]
17. Effects of working gas pressure on zirconium dioxide thin film prepared by pulsed plasma deposition: roughness, wettability, friction and wear characteristics.
Berni M; Marchiori G; Gambardella A; Boi M; Bianchi M; Russo A; Visani A; Marcacci M; Pavan PG; Lopomo NF
J Mech Behav Biomed Mater; 2017 Aug; 72():200-208. PubMed ID: 28500999
[TBL] [Abstract][Full Text] [Related]
18. Multilayers of poly(ethyleneimine)/poly(acrylic acid) coatings on Ti6Al4V acting as lubricated polymer-bearing interface.
Deng Y; Sun J; Ni X; Xiong D
J Biomed Mater Res B Appl Biomater; 2020 Jul; 108(5):2141-2152. PubMed ID: 31904181
[TBL] [Abstract][Full Text] [Related]
19. Optimizing surface characteristics for cell adhesion and proliferation on titanium plasma spray coatings on polyetheretherketone.
Yoon BJ; Xavier F; Walker BR; Grinberg S; Cammisa FP; Abjornson C
Spine J; 2016 Oct; 16(10):1238-1243. PubMed ID: 27241209
[TBL] [Abstract][Full Text] [Related]
20. Improved biotribological properties of PEEK by photo-induced graft polymerization of acrylic acid.
Zhao X; Xiong D; Wang K; Wang N
Mater Sci Eng C Mater Biol Appl; 2017 Jun; 75():777-783. PubMed ID: 28415528
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]