These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

860 related articles for article (PubMed ID: 27612848)

  • 21. Erroneous measurement of the aortic annular diameter using 2-dimensional echocardiography resulting in inappropriate CoreValve size selection: a retrospective comparison with multislice computed tomography.
    Mylotte D; Dorfmeister M; Elhmidi Y; Mazzitelli D; Bleiziffer S; Wagner A; Noterdaeme T; Lange R; Piazza N
    JACC Cardiovasc Interv; 2014 Jun; 7(6):652-61. PubMed ID: 24947721
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
    Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK
    JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography.
    Khalique OK; Kodali SK; Paradis JM; Nazif TM; Williams MR; Einstein AJ; Pearson GD; Harjai K; Grubb K; George I; Leon MB; Hahn RT
    Circ Cardiovasc Imaging; 2014 Jan; 7(1):155-63. PubMed ID: 24221192
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement.
    Buellesfeld L; Stortecky S; Kalesan B; Gloekler S; Khattab AA; Nietlispach F; Delfine V; Huber C; Eberle B; Meier B; Wenaweser P; Windecker S
    JACC Cardiovasc Interv; 2013 Jan; 6(1):72-83. PubMed ID: 23347864
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A novel contribution towards coherent and reproducible intravalvular measurement of the aortic annulus by multidetector computed tomography ahead of transcatheter aortic valve implantation.
    Dementhon J; Rioufol G; Obadia JF; Vergnat M; Green L; Croisille P; Boussel L; Peron J; Revel D; Finet G
    Arch Cardiovasc Dis; 2015 May; 108(5):281-92. PubMed ID: 25863427
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Incidence, Predictors, and Outcome of Paravalvular Leak after Transcatheter Aortic Valve Implantation.
    Hagar A; Li Y; Wei X; Peng Y; Xu Y; Ou Y; Wang Z; Wang X; Shah JP; Sihag V; Chen M; Feng Y
    J Interv Cardiol; 2020; 2020():8249497. PubMed ID: 32523474
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Impact of Annular Oversizing on Paravalvular Regurgitation and Valve Hemodynamics: New Insights From PARTNER 3.
    Ihdayhid AR; Leipsic J; Hahn RT; Pibarot P; Thourani V; Makkar R; Kodali S; Russo M; Kapadia S; Chen Y; Mack M; Webb J; Bax J; Leon MB; Blanke P
    JACC Cardiovasc Interv; 2021 Oct; 14(19):2158-2169. PubMed ID: 34620395
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Predictors of paravalvular leak following implantation of the ACURATE neo transcatheter heart valve: the PREDICT PVL study.
    Brinkert M; De Boeck B; Stämpfli SF; Wolfrum M; Moccetti F; Attinger-Toller A; Bossard M; Cuculi F; Kobza R; Toggweiler S
    Open Heart; 2020 Nov; 7(2):. PubMed ID: 33243930
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Interobserver variability of CT angiography for evaluation of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI).
    Schmidkonz C; Marwan M; Klinghammer L; Mitschke M; Schuhbaeck A; Arnold M; Lell M; Achenbach S; Pflederer T
    Eur J Radiol; 2014 Sep; 83(9):1672-8. PubMed ID: 25022977
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography.
    Leetmaa T; Hansson NC; Leipsic J; Jensen K; Poulsen SH; Andersen HR; Jensen JM; Webb J; Blanke P; Tang M; Nørgaard BL
    Circ Cardiovasc Interv; 2015 Apr; 8(4):. PubMed ID: 25873726
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement.
    Buellesfeld L; Stortecky S; Heg D; Gloekler S; Meier B; Wenaweser P; Windecker S
    EuroIntervention; 2014 Oct; 10(6):732-8. PubMed ID: 25330505
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Paravalvular leak after transcatheter aortic valve implantation (TAVI): Short-term results. Data from Polish national POL-TAVI registry.
    Kleczyński P; Zasada W; Bagieński M; Rzeszutko Ł; Sorysz D; Sobczyński R; Trębacz J; Kapelak B; Zembala M; Dudek D
    Cardiol J; 2016; 23(2):163-8. PubMed ID: 26503080
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Computed tomography predictors of mortality, stroke and conduction disturbances in women undergoing TAVR: A sub-analysis of the WIN-TAVI registry.
    Spaziano M; Chieffo A; Watanabe Y; Chandrasekhar J; Sartori S; Lefèvre T; Petronio AS; Presbitero P; Tchetche D; Iadanza A; Van Mieghem NM; Mehilli J; Mehran R; Morice MC;
    J Cardiovasc Comput Tomogr; 2018; 12(4):338-343. PubMed ID: 29735255
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve.
    Tang GHL; Zaid S; George I; Khalique OK; Abramowitz Y; Maeno Y; Makkar RR; Jilaihawi H; Kamioka N; Thourani VH; Babaliaros V; Webb JG; Htun NM; Attinger-Toller A; Ahmad H; Kaple R; Sharma K; Kozina JA; Kaneko T; Shah P; Hirji SA; Desai ND; Anwaruddin S; Jagasia D; Herrmann HC; Basra SS; Szerlip MA; Mack MJ; Mathur M; Tan CW; Don CW; Sharma R; Gafoor S; Zhang M; Kapadia SR; Mick SL; Krishnaswamy A; Amoroso N; Salemi A; Wong SC; Kini AS; Rodés-Cabau J; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1377-1387. PubMed ID: 29960755
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Hemodynamic classification of paravalvular leakage after transcatheter aortic valve implantation compared with angiographic or echocardiographic classification for prediction of 1-year mortality.
    Schoechlin S; Brennemann T; Allali A; Ruile P; Jander N; Allgeier M; Gick M; Richardt G; Neumann FJ; Abdel-Wahab M
    Catheter Cardiovasc Interv; 2018 May; 91(6):E56-E63. PubMed ID: 29105984
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Association of Relative Left Ventricular Outflow Tract Area and Transcatheter Aortic Valve Replacement Related Paravalvular Leak.
    Gupta K; Villablanca P; Gonzalez PE; O'Neill B; O'Neill WW; Wang DD; Fang JX; Giustino G; Frisoli T; Lee JC
    J Soc Cardiovasc Angiogr Interv; 2024 Mar; 3(3Part B):101294. PubMed ID: 39131220
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Risk factors for paravalvular leak after transcatheter aortic valve replacement.
    Pollari F; Dell'Aquila AM; Söhn C; Marianowicz J; Wiehofsky P; Schwab J; Pauschinger M; Hitzl W; Fischlein T; Pfeiffer S
    J Thorac Cardiovasc Surg; 2019 Apr; 157(4):1406-1415.e3. PubMed ID: 30482527
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Multidetector row computed tomography parameters associated with paravalvular regurgitation after transcatheter aortic valve implantation.
    Katsanos S; Ewe SH; Debonnaire P; van der Kley F; de Weger A; Palmen M; Scholte AJ; Schalij MJ; Bax JJ; Marsan NA; Delgado V
    Am J Cardiol; 2013 Dec; 112(11):1800-6. PubMed ID: 24035163
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 43.