These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

296 related articles for article (PubMed ID: 2761546)

  • 1. [Clinical assessment of a new glucose reflectance meter (Glucoscot II) for the detection of neonatal hypoglycemias].
    Leibundgut KE; Bucher HU; Mieth D; Duc G
    Monatsschr Kinderheilkd; 1989 Jun; 137(6):330-2. PubMed ID: 2761546
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Assessment of neonatal hypoglycemia with 2 test strip methods].
    Leibundgut KE; Bucher HU; Mieth D; Duc G
    Monatsschr Kinderheilkd; 1988 Oct; 136(10):694-7. PubMed ID: 3237224
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical utility of a glucose reflectance meter for screening neonates for hypoglycemia.
    Garland J; Alex C; Gleisberg D; Havens P
    J Perinatol; 1996; 16(4):250-3; quiz 254-5. PubMed ID: 8866292
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical utility and accuracy of a blood glucose meter for the detection of neonatal hypoglycemia.
    Hamid MH; Chishti AL; Maqbool S
    J Coll Physicians Surg Pak; 2004 Apr; 14(4):225-8. PubMed ID: 15228827
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Determination of low blood glucose levels in newborns with the reflectance photometer (author's transl)].
    Dominick HC; Humbel R; Bachmann KD; Banauch D; Carstensen CA
    Geburtshilfe Frauenheilkd; 1979 Aug; 39(8):642-8. PubMed ID: 478265
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy and reliability of two methods of screening for hypoglycemia in neonates.
    Ho KL; Loke HL; Tan KW
    J Singapore Paediatr Soc; 1991; 33(3-4):156-8. PubMed ID: 1812332
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reflotest hypoglycemie--a more sensitive screening method for neonatal hypoglycaemia.
    Loke HL; Lun KC
    Singapore Med J; 1986 Aug; 27(4):321-5. PubMed ID: 3798145
    [No Abstract]   [Full Text] [Related]  

  • 8. Measuring neonatal blood glucose with a reflectance meter and test stripts.
    Levkoff AH; Duncan RC; Urquhart C; Gershanik JJ
    Isr J Med Sci; 1971 Apr; 7(4):598-600. PubMed ID: 5580788
    [No Abstract]   [Full Text] [Related]  

  • 9. [Is reliable blood glucose determination in the newborn infant possible with the small reflectance meter Reflolux S?].
    Schlebusch H; Niesen M; Paffenholz I
    Klin Padiatr; 1993; 205(2):111-5. PubMed ID: 8487477
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increased cerebral blood flow and plasma epinephrine in hypoglycemic, preterm neonates.
    Pryds O; Christensen NJ; Friis-Hansen B
    Pediatrics; 1990 Feb; 85(2):172-6. PubMed ID: 2296504
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of hypoglycemia by children with type 1 diabetes 6 to 11 years of age and their parents: a field study.
    Gonder-Frederick L; Zrebiec J; Bauchowitz A; Lee J; Cox D; Ritterband L; Kovatchev B; Clarke W
    Pediatrics; 2008 Mar; 121(3):e489-95. PubMed ID: 18310169
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of dextrostix and dextrostix reflectance meters in the diagnosis of neonatal hypoglycemia.
    Harvey DR; Cooper LV; Fancourt RF; Levene M; Schoberg T
    J Perinat Med; 1976; 4(2):106-10. PubMed ID: 966130
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of blood glucose concentrations determined by four visually read reagent strips.
    MacManus MP; Neely RD; Bell PM
    Ulster Med J; 1988 Apr; 57(1):76-9. PubMed ID: 3420725
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a dextrostix scale for hypoglycemia.
    Dorchy H; Leb H
    Helv Paediatr Acta; 1974 Dec; 29(6):565-73. PubMed ID: 4457514
    [No Abstract]   [Full Text] [Related]  

  • 15. Comparison of two methods of bedside blood glucose screening in the NICU: evaluation of accuracy and reliability.
    Martin S; Jensen R; Daly L; Jergenson C; Johnson MB; Buell T
    Neonatal Netw; 1997 Mar; 16(2):39-43. PubMed ID: 9087010
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice.
    Ho HT; Yeung WK; Young BW
    Arch Dis Child Fetal Neonatal Ed; 2004 Jul; 89(4):F356-9. PubMed ID: 15210675
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Biochemical glucose test x glucose strip test: results of 464 determinations in pre-term infants].
    Falcão MC; Ramos JL
    Rev Hosp Clin Fac Med Sao Paulo; 1997; 52(5):250-3. PubMed ID: 9595778
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a new glucose reflectance meter for use in the neonatal intensive care unit.
    Vitanza A; Giacoia GP; West K
    J Perinatol; 1988; 8(1):43-5. PubMed ID: 3236094
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Comparison of 2 semi-quantitative methods for evaluating blood glucose in newborn infants].
    Dupont G; Moriette G; Pajot N; Walti H; De Gamarra E; Relier JP
    Arch Fr Pediatr; 1986 Feb; 43(2):111-3. PubMed ID: 3718153
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection of neonatal hypoglycemia--a comparison of three reagent strips.
    Brown MS; Nelson S; Stewart BJ
    Nurse Pract; 1988 Oct; 13(10):15-6, 18, 23-4. PubMed ID: 3067153
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.