These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

512 related articles for article (PubMed ID: 27619317)

  • 1. Comparison of global cerebral blood flow measured by phase-contrast mapping MRI with
    Vestergaard MB; Lindberg U; Aachmann-Andersen NJ; Lisbjerg K; Christensen SJ; Rasmussen P; Olsen NV; Law I; Larsson HB; Henriksen OM
    J Magn Reson Imaging; 2017 Mar; 45(3):692-699. PubMed ID: 27619317
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive method for measurement of cerebral blood flow using O-15 water PET/MRI with ASL correlation.
    Okazawa H; Higashino Y; Tsujikawa T; Arishima H; Mori T; Kiyono Y; Kimura H; Kikuta KI
    Eur J Radiol; 2018 Aug; 105():102-109. PubMed ID: 30017265
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous phase-contrast MRI and PET for noninvasive quantification of cerebral blood flow and reactivity in healthy subjects and patients with cerebrovascular disease.
    Ishii Y; Thamm T; Guo J; Khalighi MM; Wardak M; Holley D; Gandhi H; Park JH; Shen B; Steinberg GK; Chin FT; Zaharchuk G; Fan AP
    J Magn Reson Imaging; 2020 Jan; 51(1):183-194. PubMed ID: 31044459
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Phase contrast mapping MRI measurements of global cerebral blood flow across different perfusion states - A direct comparison with
    Puig O; Vestergaard MB; Lindberg U; Hansen AE; Ulrich A; Andersen FL; Johannesen HH; Rostrup E; Law I; Larsson HB; Henriksen OM
    J Cereb Blood Flow Metab; 2019 Dec; 39(12):2368-2378. PubMed ID: 30200799
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative cerebral blood flow with bolus tracking perfusion MRI: measurements in porcine model and comparison with H(2)(15)O PET.
    Kellner E; Mix M; Reisert M; Förster K; Nguyen-Thanh T; Splitthoff DN; Gall P; Kiselev VG; Mader I
    Magn Reson Med; 2014 Dec; 72(6):1723-34. PubMed ID: 24375612
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantification of cerebral blood flow in healthy volunteers and type 1 diabetic patients: comparison of MRI arterial spin labeling and [(15)O]H2O positron emission tomography (PET).
    van Golen LW; Kuijer JP; Huisman MC; IJzerman RG; Barkhof F; Diamant M; Lammertsma AA
    J Magn Reson Imaging; 2014 Dec; 40(6):1300-9. PubMed ID: 24214919
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative cerebral perfusion imaging in children and young adults with Moyamoya disease: comparison of arterial spin-labeling-MRI and H(2)[(15)O]-PET.
    Goetti R; Warnock G; Kuhn FP; Guggenberger R; O'Gorman R; Buck A; Khan N; Scheer I
    AJNR Am J Neuroradiol; 2014 May; 35(5):1022-8. PubMed ID: 24335546
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography.
    Henriksen OM; Larsson HB; Hansen AE; Grüner JM; Law I; Rostrup E
    J Magn Reson Imaging; 2012 Jun; 35(6):1290-9. PubMed ID: 22246715
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive Quantification of Cerebral Blood Flow Using Hybrid PET/MR Imaging to Extract the [
    Narciso L; Ssali T; Liu L; Jesso S; Hicks JW; Anazodo U; Finger E; St Lawrence K
    J Magn Reson Imaging; 2022 Oct; 56(4):1243-1255. PubMed ID: 35226390
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of kinetic modeling of [
    Vestergaard MB; Calvo OP; Hansen AE; Rosenbaum S; Larsson HBW; Henriksen OM; Law I
    Neuroimage; 2021 Jun; 233():117950. PubMed ID: 33716159
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of regional tracer delay on CBF in healthy subjects measured with dynamic susceptibility contrast-enhanced MRI: comparison with 15O-PET.
    Ibaraki M; Shimosegawa E; Toyoshima H; Ishigame K; Ito H; Takahashi K; Miura S; Kanno I
    Magn Reson Med Sci; 2005; 4(1):27-34. PubMed ID: 16127251
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using (15)O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets.
    Andersen JB; Henning WS; Lindberg U; Ladefoged CN; Højgaard L; Greisen G; Law I
    J Cereb Blood Flow Metab; 2015 Nov; 35(11):1703-10. PubMed ID: 26058699
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of cerebral blood flow acquired by simultaneous [15O]water positron emission tomography and arterial spin labeling magnetic resonance imaging.
    Zhang K; Herzog H; Mauler J; Filss C; Okell TW; Kops ER; Tellmann L; Fischer T; Brocke B; Sturm W; Coenen HH; Shah NJ
    J Cereb Blood Flow Metab; 2014 Aug; 34(8):1373-80. PubMed ID: 24849665
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cerebrovascular occlusive disease: quantitative cerebral blood flow using dynamic susceptibility contrast mr imaging correlates with quantitative H2[15O] PET.
    Vakil P; Lee JJ; Mouannes-Srour JJ; Derdeyn CP; Carroll TJ
    Radiology; 2013 Mar; 266(3):879-86. PubMed ID: 23297337
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-invasive quantification of cerebral blood flow for rats by microPET imaging of 15O labelled water: the application of a cardiac time-activity curve for the tracer arterial input function.
    Yee SH; Jerabek PA; Fox PT
    Nucl Med Commun; 2005 Oct; 26(10):903-11. PubMed ID: 16160650
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T
    Larsson HBW; Vestergaard MB; Lindberg U; Iversen HK; Cramer SP
    J Magn Reson Imaging; 2017 Jun; 45(6):1809-1820. PubMed ID: 27731907
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cerebrovascular reactivity measurements using simultaneous
    Zhao MY; Fan AP; Chen DY; Sokolska MJ; Guo J; Ishii Y; Shin DD; Khalighi MM; Holley D; Halbert K; Otte A; Williams B; Rostami T; Park JH; Shen B; Zaharchuk G
    Neuroimage; 2021 Jun; 233():117955. PubMed ID: 33716155
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of simultaneous arterial spin labeling MRI and
    Puig O; Henriksen OM; Vestergaard MB; Hansen AE; Andersen FL; Ladefoged CN; Rostrup E; Larsson HB; Lindberg U; Law I
    J Cereb Blood Flow Metab; 2020 Aug; 40(8):1621-1633. PubMed ID: 31500521
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimization of phase-contrast MRI for the quantification of whole-brain cerebral blood flow.
    Peng SL; Su P; Wang FN; Cao Y; Zhang R; Lu H; Liu P
    J Magn Reson Imaging; 2015 Oct; 42(4):1126-33. PubMed ID: 25676350
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spectral analysis of 99mTc-HMPAO for estimating cerebral blood flow: a comparison with H2(15)O PET.
    Takasawa M; Murase K; Oku N; Kawamata M; Nagayoshi M; Imaizumi M; Yoshikawa T; Osaki Y; Kimura Y; Kajimoto K; Kitagawa K; Hori M; Hatazawa J
    Ann Nucl Med; 2004 May; 18(3):243-9. PubMed ID: 15233286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.