These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

386 related articles for article (PubMed ID: 27631849)

  • 1. HBA1C AND MEAN GLUCOSE DERIVED FROM SHORT-TERM CONTINUOUS GLUCOSE MONITORING ASSESSMENT DO NOT CORRELATE IN PATIENTS WITH HBA1C >8.
    Yamada E; Okada S; Nakajima Y; Bastie CC; Vatish M; Tagaya Y; Osaki A; Shimoda Y; Shibusawa R; Saito T; Okamura T; Ozawa A; Yamada M
    Endocr Pract; 2017 Jan; 23(1):10-16. PubMed ID: 27631849
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the relationship between glycated hemoglobin A1c and mean glucose levels derived from the professional continuous flash glucose monitoring system.
    Yamada M; Okada S; Oda H; Nakajima Y; C Bastie C; Kasai Y; Osaki A; Shimoda Y; Shibusawa R; Uehara R; Saito T; Ozawa A; Yamada E
    Endocr J; 2020 May; 67(5):531-536. PubMed ID: 32023560
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis.
    Yeh HC; Brown TT; Maruthur N; Ranasinghe P; Berger Z; Suh YD; Wilson LM; Haberl EB; Brick J; Bass EB; Golden SH
    Ann Intern Med; 2012 Sep; 157(5):336-47. PubMed ID: 22777524
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The importance of HbA1c and glucose variability in patients with type 1 and type 2 diabetes: outcome of continuous glucose monitoring (CGM).
    Sartore G; Chilelli NC; Burlina S; Di Stefano P; Piarulli F; Fedele D; Mosca A; Lapolla A
    Acta Diabetol; 2012 Dec; 49 Suppl 1():S153-60. PubMed ID: 22466072
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials.
    Dicembrini I; Cosentino C; Monami M; Mannucci E; Pala L
    Acta Diabetol; 2021 Apr; 58(4):401-410. PubMed ID: 32789691
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of short-term iPRO continuous glucose monitoring on hemoglobin A1c levels in clinical practice.
    Pepper GM; Steinsapir J; Reynolds K
    Diabetes Technol Ther; 2012 Aug; 14(8):654-7. PubMed ID: 22690923
    [TBL] [Abstract][Full Text] [Related]  

  • 7. SELF BLOOD GLUCOSE MONITORING UNDERESTIMATES HYPERGLYCEMIA AND HYPOGLYCEMIA AS COMPARED TO CONTINUOUS GLUCOSE MONITORING IN TYPE 1 AND TYPE 2 DIABETES.
    Mangrola D; Cox C; Furman AS; Krishnan S; Karakas SE
    Endocr Pract; 2018 Jan; 24(1):47-52. PubMed ID: 29144814
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Association of Real-time Continuous Glucose Monitoring With Glycemic Control and Acute Metabolic Events Among Patients With Insulin-Treated Diabetes.
    Karter AJ; Parker MM; Moffet HH; Gilliam LK; Dlott R
    JAMA; 2021 Jun; 325(22):2273-2284. PubMed ID: 34077502
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Poincaré plot quantification for assessing glucose variability from continuous glucose monitoring systems and a new risk marker for hypoglycemia: application to type 1 diabetes patients switching to continuous subcutaneous insulin infusion.
    Crenier L
    Diabetes Technol Ther; 2014 Apr; 16(4):247-54. PubMed ID: 24237387
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Beyond HbA1c.
    Bloomgarden Z
    J Diabetes; 2017 Dec; 9(12):1052-1053. PubMed ID: 28792665
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.
    Beck RW; Riddlesworth T; Ruedy K; Ahmann A; Bergenstal R; Haller S; Kollman C; Kruger D; McGill JB; Polonsky W; Toschi E; Wolpert H; Price D;
    JAMA; 2017 Jan; 317(4):371-378. PubMed ID: 28118453
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Personal continuous glucose monitoring (CGM) in diabetes management: review of the literature and implementation for practical use.
    Joubert M; Reznik Y
    Diabetes Res Clin Pract; 2012 Jun; 96(3):294-305. PubMed ID: 22209014
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of lowering nighttime and breakfast glucose levels with sensor-augmented pump therapy on hemoglobin A1c levels in type 1 diabetes.
    Maahs DM; Chase HP; Westfall E; Slover R; Huang S; Shin JJ; Kaufman FR; Pyle L; Snell-Bergeon JK
    Diabetes Technol Ther; 2014 May; 16(5):284-91. PubMed ID: 24450776
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Association Between HbA
    Seyed Ahmadi S; Westman K; Pivodic A; Ólafsdóttir AF; Dahlqvist S; Hirsch IB; Hellman J; Ekelund M; Heise T; Polonsky W; Wijkman M; Schwarcz E; Lind M
    Diabetes Care; 2020 Sep; 43(9):2017-2024. PubMed ID: 32641374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of internet monitoring with continuous glucose monitoring in insulin-requiring type 2 diabetes mellitus.
    Tildesley HD; Wright AM; Chan JH; Mazanderani AB; Ross SA; Tildesley HG; Lee AM; Tang TS; White AS
    Can J Diabetes; 2013 Oct; 37(5):305-8. PubMed ID: 24500556
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect on glycemic control by short- and long-term use of continuous glucose monitoring in clinical practice.
    Anderson J; Attvall S; Sternemalm L; Pivodic A; Fahlén M; Hanås R; Ekeroth G; Lind M
    J Diabetes Sci Technol; 2011 Nov; 5(6):1472-9. PubMed ID: 22226268
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of Continuous Glucose Monitoring on Hypoglycemia in Older Adults With Type 1 Diabetes: A Randomized Clinical Trial.
    Pratley RE; Kanapka LG; Rickels MR; Ahmann A; Aleppo G; Beck R; Bhargava A; Bode BW; Carlson A; Chaytor NS; Fox DS; Goland R; Hirsch IB; Kruger D; Kudva YC; Levy C; McGill JB; Peters A; Philipson L; Philis-Tsimikas A; Pop-Busui R; Shah VN; Thompson M; Vendrame F; Verdejo A; Weinstock RS; Young L; Miller KM;
    JAMA; 2020 Jun; 323(23):2397-2406. PubMed ID: 32543682
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Benefits of short-term professional continuous glucose monitoring in clinical practice.
    Leinung M; Nardacci E; Patel N; Bettadahalli S; Paika K; Thompson S
    Diabetes Technol Ther; 2013 Sep; 15(9):744-7. PubMed ID: 23786229
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Integrated sensor-augmented pump therapy systems [the MiniMed® Paradigm™ Veo system and the Vibe™ and G4® PLATINUM CGM (continuous glucose monitoring) system] for managing blood glucose levels in type 1 diabetes: a systematic review and economic evaluation.
    Riemsma R; Corro Ramos I; Birnie R; Büyükkaramikli N; Armstrong N; Ryder S; Duffy S; Worthy G; Al M; Severens J; Kleijnen J
    Health Technol Assess; 2016 Feb; 20(17):v-xxxi, 1-251. PubMed ID: 26933827
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relationship of continuous glucose monitoring-related metrics with HbA1c and residual β-cell function in Japanese patients with type 1 diabetes.
    Babaya N; Noso S; Hiromine Y; Taketomo Y; Niwano F; Yoshida S; Yasutake S; Kawabata Y; Ikegami H
    Sci Rep; 2021 Feb; 11(1):4006. PubMed ID: 33597626
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.