287 related articles for article (PubMed ID: 27632261)
1. The Impact of Force Transmission on Narrow-Body Dental Implants Made of Commercially Pure Titanium and Titanium Zirconia Alloy with a Conical Implant-Abutment Connection: An Experimental Pilot Study.
Nelson K; Schmelzeisen R; Taylor TD; Zabler S; Wiest W; Fretwurst T
Int J Oral Maxillofac Implants; 2016; 31(5):1066-71. PubMed ID: 27632261
[TBL] [Abstract][Full Text] [Related]
2. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.
Mühlemann S; Truninger TC; Stawarczyk B; Hämmerle CH; Sailer I
Clin Oral Implants Res; 2014 Jan; 25(1):74-81. PubMed ID: 23735182
[TBL] [Abstract][Full Text] [Related]
3. Rotational Load Fatigue Performance of Titanium vs Titanium-Zirconium Implant-Abutment Connections.
Leo SJ; Tan MY; Yee SHX; Lee FKF; Tan KBC
Int J Oral Maxillofac Implants; 2022; 37(4):740-747. PubMed ID: 35904830
[TBL] [Abstract][Full Text] [Related]
4. Implant-abutment interface: a comparison of the ultimate force to failure among narrow-diameter implant systems.
Imam AY; Moshaverinia A; McGlumphy EA
J Prosthet Dent; 2014 Aug; 112(2):136-42. PubMed ID: 24725612
[TBL] [Abstract][Full Text] [Related]
5. In vitro assessment of three types of zirconia implant abutments under static load.
Kim JS; Raigrodski AJ; Flinn BD; Rubenstein JE; Chung KH; Mancl LA
J Prosthet Dent; 2013 Apr; 109(4):255-63. PubMed ID: 23566607
[TBL] [Abstract][Full Text] [Related]
6. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept.
Sailer I; Asgeirsson AG; Thoma DS; Fehmer V; Aspelund T; Özcan M; Pjetursson BE
Clin Oral Implants Res; 2018 Apr; 29(4):411-423. PubMed ID: 29527740
[TBL] [Abstract][Full Text] [Related]
7. Bending moments and types of failure of zirconia and titanium abutments with internal implant-abutment connections: a laboratory study.
Leutert CR; Stawarczyk B; Truninger TC; Hämmerle CH; Sailer I
Int J Oral Maxillofac Implants; 2012; 27(3):505-12. PubMed ID: 22616042
[TBL] [Abstract][Full Text] [Related]
8. Implant deformation and implant-abutment fracture resistance after standardized artificial aging: An in vitro study.
Zhai Z; Nakano T; Chen Y; Watanabe S; Matsuoka T; Ishigaki S
Clin Implant Dent Relat Res; 2023 Feb; 25(1):107-117. PubMed ID: 36415012
[TBL] [Abstract][Full Text] [Related]
9. An in vitro pilot study of abutment stability during loading in new and fatigue-loaded conical dental implants using synchrotron-based radiography.
Rack T; Zabler S; Rack A; Riesemeier H; Nelson K
Int J Oral Maxillofac Implants; 2013; 28(1):44-50. PubMed ID: 23377046
[TBL] [Abstract][Full Text] [Related]
10. Fracture resistance of titanium and zirconia abutments: an in vitro study.
Foong JK; Judge RB; Palamara JE; Swain MV
J Prosthet Dent; 2013 May; 109(5):304-12. PubMed ID: 23684280
[TBL] [Abstract][Full Text] [Related]
11. Stress distribution and microgap formation in angulated zirconia abutments with a titanium base in narrow diameter implants: A 3D finite element analysis.
Zhang Y; Yu P; Yu H
Int J Numer Method Biomed Eng; 2022 Jul; 38(7):e3610. PubMed ID: 35490303
[TBL] [Abstract][Full Text] [Related]
12. Displacement and performance of abutments in narrow-diameter implants with different internal connections.
Jacobs N; Seghi R; Johnston WM; Yilmaz B
J Prosthet Dent; 2022 Jan; 127(1):100-106. PubMed ID: 33413986
[TBL] [Abstract][Full Text] [Related]
13. Comparison of fracture resistance of pressable metal ceramic custom implant abutment with a commercially fabricated CAD/CAM zirconia implant abutment.
Protopapadaki M; Monaco EA; Kim HI; Davis EL
J Prosthet Dent; 2013 Nov; 110(5):389-96. PubMed ID: 24011801
[TBL] [Abstract][Full Text] [Related]
14. Stiffness, strength, and failure modes of implant-supported monolithic lithium disilicate crowns: influence of titanium and zirconia abutments.
Joda T; Bürki A; Bethge S; Brägger U; Zysset P
Int J Oral Maxillofac Implants; 2015; 30(6):1272-9. PubMed ID: 26574852
[TBL] [Abstract][Full Text] [Related]
15. A pilot study of joint stability at the zirconium or titanium abutment/titanium implant interface.
Cavusoglu Y; Akça K; Gürbüz R; Cehreli MC
Int J Oral Maxillofac Implants; 2014; 29(2):338-43. PubMed ID: 24683559
[TBL] [Abstract][Full Text] [Related]
16. Load to failure of different zirconia abutments for an internal hexagon implant.
Yilmaz B; Salaita LG; Seidt JD; McGlumphy EA; Clelland NL
J Prosthet Dent; 2015 Sep; 114(3):373-7. PubMed ID: 25976709
[TBL] [Abstract][Full Text] [Related]
17. Wear at the titanium-zirconia implant-abutment interface: a pilot study.
Klotz MW; Taylor TD; Goldberg AJ
Int J Oral Maxillofac Implants; 2011; 26(5):970-5. PubMed ID: 22010078
[TBL] [Abstract][Full Text] [Related]
18. Fracture resistance of inter-joined zirconia abutment of dental implant system with injection molding technique.
Yang J; Wang K; Liu G; Wang D
Clin Oral Implants Res; 2013 Nov; 24(11):1247-50. PubMed ID: 22809060
[TBL] [Abstract][Full Text] [Related]
19. Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants.
Çaglar A; Bal BT; Karakoca S; Aydın C; Yılmaz H; Sarısoy S
Int J Oral Maxillofac Implants; 2011; 26(5):961-9. PubMed ID: 22010077
[TBL] [Abstract][Full Text] [Related]
20. Three-Dimensional Deformation and Wear of Internal Implant-Abutment Connection: A Comparative Biomechanical Study Using Titanium and Zirconia.
Nam RK; Lee SJ; Park EJ; Kwon HB; Yoon HI
Int J Oral Maxillofac Implants; 2018; 33(6):1279-1286. PubMed ID: 30427958
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]