BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

917 related articles for article (PubMed ID: 27633157)

  • 1. Comparison of the diagnostic performance of 2 core biopsy needles for EUS-guided tissue acquisition from solid pancreatic lesions.
    Nayar MK; Paranandi B; Dawwas MF; Leeds JS; Darne A; Haugk B; Majumdar D; Ahmed MM; Oppong KW
    Gastrointest Endosc; 2017 May; 85(5):1017-1024. PubMed ID: 27633157
    [TBL] [Abstract][Full Text] [Related]  

  • 2. EUS-guided reverse bevel fine-needle biopsy sampling and open tip fine-needle aspiration in solid pancreatic lesions - a prospective, comparative study.
    Hedenström P; Demir A; Khodakaram K; Nilsson O; Sadik R
    Scand J Gastroenterol; 2018 Feb; 53(2):231-237. PubMed ID: 29301477
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study.
    Lee YN; Moon JH; Kim HK; Choi HJ; Choi MH; Kim DC; Lee TH; Cha SW; Cho YD; Park SH
    Endoscopy; 2014 Dec; 46(12):1056-62. PubMed ID: 25098611
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles.
    Yang MJ; Yim H; Hwang JC; Lee D; Kim YB; Lim SG; Kim SS; Kang JK; Yoo BM; Kim JH
    BMC Gastroenterol; 2015 Sep; 15():122. PubMed ID: 26419845
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS fine-needle biopsy device.
    van Riet PA; Larghi A; Attili F; Rindi G; Nguyen NQ; Ruszkiewicz A; Kitano M; Chikugo T; Aslanian H; Farrell J; Robert M; Adeniran A; Van Der Merwe S; Roskams T; Chang K; Lin F; Lee JG; Arcidiacono PG; Petrone M; Doglioni C; Iglesias-Garcia J; Abdulkader I; Giovannini M; Bories E; Poizat F; Santo E; Scapa E; Marmor S; Bucobo JC; Buscaglia JM; Heimann A; Wu M; Baldaque-Silva F; Moro CF; Erler NS; Biermann K; Poley JW; Cahen DL; Bruno MJ
    Gastrointest Endosc; 2019 Feb; 89(2):329-339. PubMed ID: 30367877
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of EUS-guided fine-needle biopsy sampling with a new core needle on the need for onsite cytopathologic assessment: a preliminary study.
    Rodrigues-Pinto E; Jalaj S; Grimm IS; Baron TH
    Gastrointest Endosc; 2016 Dec; 84(6):1040-1046. PubMed ID: 27345131
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study.
    Larghi A; Iglesias-Garcia J; Poley JW; Monges G; Petrone MC; Rindi G; Abdulkader I; Arcidiacono PG; Costamagna G; Biermann K; Bories E; Doglioni C; Dominguez-Muñoz JE; Hassan C; Bruno M; Giovannini M
    Surg Endosc; 2013 Oct; 27(10):3733-8. PubMed ID: 23644834
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions.
    Iwashita T; Nakai Y; Samarasena JB; Park DH; Zhang Z; Gu M; Lee JG; Chang KJ
    Gastrointest Endosc; 2013 Jun; 77(6):909-15. PubMed ID: 23433596
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Core needle versus standard needle for endoscopic ultrasound-guided biopsy of solid pancreatic masses: a randomized crossover study.
    Vanbiervliet G; Napoléon B; Saint Paul MC; Sakarovitch C; Wangermez M; Bichard P; Subtil C; Koch S; Grandval P; Gincul R; Karsenti D; Heyries L; Duchmann JC; Bourgaux JF; Levy M; Calament G; Fumex F; Pujol B; Lefort C; Poincloux L; Pagenault M; Bonin EA; Fabre M; Barthet M
    Endoscopy; 2014 Dec; 46(12):1063-70. PubMed ID: 25098612
    [TBL] [Abstract][Full Text] [Related]  

  • 10. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.
    Kandel P; Tranesh G; Nassar A; Bingham R; Raimondo M; Woodward TA; Gomez V; Wallace MB
    Gastrointest Endosc; 2016 Dec; 84(6):1034-1039. PubMed ID: 27018087
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cohort study comparing the diagnostic yields of 2 different EUS fine-needle biopsy needles.
    Abdelfatah MM; Grimm IS; Gangarosa LM; Baron TH
    Gastrointest Endosc; 2018 Feb; 87(2):495-500. PubMed ID: 28882575
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the Diagnostic Yield of the Standard 22-Gauge Needle and the New 20-Gauge Forward-Bevel Core Biopsy Needle for Endoscopic Ultrasound-Guided Tissue Acquisition from Pancreatic Lesions.
    Fujie S; Ishiwatari H; Sasaki K; Sato J; Matsubayashi H; Yoshida M; Ito S; Kawata N; Imai K; Kakushima N; Takizawa K; Hotta K; Ono H
    Gut Liver; 2019 May; 13(3):349-355. PubMed ID: 30600677
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network meta-analysis.
    Facciorusso A; Wani S; Triantafyllou K; Tziatzios G; Cannizzaro R; Muscatiello N; Singh S
    Gastrointest Endosc; 2019 Dec; 90(6):893-903.e7. PubMed ID: 31310744
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions.
    Bang JY; Hebert-Magee S; Navaneethan U; Hasan MK; Hawes R; Varadarajulu S
    Gastrointest Endosc; 2018 Jun; 87(6):1432-1438. PubMed ID: 29305893
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The diagnostic and cellularity yield of reverse bevel versus fork-tip fine needle biopsy.
    Abdelfatah MM; Hamed A; Koutlas NJ; Aly FZ
    Diagn Cytopathol; 2018 Aug; 46(8):649-655. PubMed ID: 29737018
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endoscopic ultrasound-guided fine needle aspiration and biopsy using a 22-gauge needle with side fenestration in pancreatic cystic lesions.
    Barresi L; Tarantino I; Traina M; Granata A; Curcio G; Azzopardi N; Baccarini P; Liotta R; Fornelli A; Maimone A; Jovine E; Cennamo V; Fabbri C
    Dig Liver Dis; 2014 Jan; 46(1):45-50. PubMed ID: 23916241
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Histologic diagnosis of pancreatic masses using 25-gauge endoscopic ultrasound needles with and without a core trap: a multicenter randomized trial.
    Kamata K; Kitano M; Yasukawa S; Kudo M; Chiba Y; Ogura T; Higuchi K; Fukutake N; Ashida R; Yamasaki T; Nebiki H; Hirose S; Hoki N; Asada M; Yazumi S; Takaoka M; Okazaki K; Matsuda F; Okabe Y; Yanagisawa A
    Endoscopy; 2016 Jul; 48(7):632-8. PubMed ID: 27129137
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions.
    Bang JY; Hebert-Magee S; Trevino J; Ramesh J; Varadarajulu S
    Gastrointest Endosc; 2012 Aug; 76(2):321-7. PubMed ID: 22658389
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 22-Gauge biopsy needles have a better histological diagnostic yield in the discrimination of specific pancreatic solid neoplasms.
    Jiang H; Guo J; Wang K; Zhu H; Chen J; Xu C; Wang D; Jin Z
    Scand J Gastroenterol; 2019 Jan; 54(1):101-107. PubMed ID: 30731044
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Randomized trial comparing a side-port needle and standard needle for EUS-guided histology of pancreatic lesions.
    Ishiwatari H; Hayashi T; Kawakami H; Isayama H; Hisai H; Itoi T; Ono M; Kawakubo K; Yamamoto N; Tanaka M; Itokawa F; Oshiro H; Sonoda T; Hasegawa T;
    Gastrointest Endosc; 2016 Oct; 84(4):670-8. PubMed ID: 26995688
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 46.