BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

925 related articles for article (PubMed ID: 27633157)

  • 21. Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial.
    Noh DH; Choi K; Gu S; Cho J; Jang KT; Woo YS; Lee KT; Lee JK; Lee KH
    Scand J Gastroenterol; 2018 Jan; 53(1):94-99. PubMed ID: 29065734
    [TBL] [Abstract][Full Text] [Related]  

  • 22. High and low negative pressure suction techniques in EUS-guided fine-needle tissue acquisition by using 25-gauge needles: a multicenter, prospective, randomized, controlled trial.
    Kudo T; Kawakami H; Hayashi T; Yasuda I; Mukai T; Inoue H; Katanuma A; Kawakubo K; Ishiwatari H; Doi S; Yamada R; Maguchi H; Isayama H; Mitsuhashi T; Sakamoto N;
    Gastrointest Endosc; 2014 Dec; 80(6):1030-7.e1. PubMed ID: 24890422
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparative diagnostic performance of end-cutting fine-needle biopsy needles for EUS tissue sampling of solid pancreatic masses: a network meta-analysis.
    Gkolfakis P; Crinò SF; Tziatzios G; Ramai D; Papaefthymiou A; Papanikolaou IS; Triantafyllou K; Arvanitakis M; Lisotti A; Fusaroli P; Mangiavillano B; Carrara S; Repici A; Hassan C; Facciorusso A
    Gastrointest Endosc; 2022 Jun; 95(6):1067-1077.e15. PubMed ID: 35124072
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Randomized Trial Comparing the Flexible 19G and 25G Needles for Endoscopic Ultrasound-Guided Fine Needle Aspiration of Solid Pancreatic Mass Lesions.
    Ramesh J; Bang JY; Hebert-Magee S; Trevino J; Eltoum I; Frost A; Hasan MK; Logue A; Hawes R; Varadarajulu S
    Pancreas; 2015 Jan; 44(1):128-33. PubMed ID: 25232713
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The cellularity yield of three different 22-gauge endoscopic ultrasound fine needle aspiration needles.
    Othman MO; Abdelfatah MM; Padilla O; Hussinat M; Elhanafi S; Eloliby M; Torabi A; Hakim N; Boman DA
    Diagn Cytopathol; 2017 May; 45(5):426-432. PubMed ID: 28261978
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore™ needle: A multicenter randomized trial.
    Di Mitri R; Mocciaro F; Antonini F; Scimeca D; Conte E; Bonaccorso A; Scibetta N; Unti E; Fornelli A; Giorgini S; Binda C; Macarri G; Larghi A; Fabbri C
    Dig Liver Dis; 2020 Feb; 52(2):178-184. PubMed ID: 31601535
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluating triage protocols for endoscopic ultrasound-guided fine needle biopsies of the pancreas.
    Fitzpatrick MJ; Hernandez-Barco YG; Krishnan K; Casey B; Pitman MB
    J Am Soc Cytopathol; 2020; 9(5):396-404. PubMed ID: 32620535
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Endoscopic ultrasound core needle for diagnosing of solid pancreatic lesions: is rapid on-site evaluation really necessary?
    Arena M; Eusebi LH; Pellicano R; Palamara MA; Iabichino G; Consolo P; Fagoonee S; Opocher E; Barabino M; Luigiano C
    Minerva Med; 2017 Dec; 108(6):547-553. PubMed ID: 28750500
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimizing EUS-guided liver biopsy sampling: comprehensive assessment of needle types and tissue acquisition techniques.
    Schulman AR; Thompson CC; Odze R; Chan WW; Ryou M
    Gastrointest Endosc; 2017 Feb; 85(2):419-426. PubMed ID: 27530070
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses.
    Park SW; Chung MJ; Lee SH; Lee HS; Lee HJ; Park JY; Park SW; Song SY; Kim H; Chung JB; Bang S
    PLoS One; 2016; 11(5):e0154401. PubMed ID: 27149404
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A pilot study of EUS-guided through-the-needle forceps biopsy (with video).
    Nakai Y; Isayama H; Chang KJ; Yamamoto N; Mizuno S; Mohri D; Kogure H; Matsubara S; Tada M; Koike K
    Gastrointest Endosc; 2016 Jul; 84(1):158-62. PubMed ID: 26772889
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses.
    Nakai Y; Isayama H; Chang KJ; Yamamoto N; Hamada T; Uchino R; Mizuno S; Miyabayashi K; Yamamoto K; Kawakubo K; Kogure H; Sasaki T; Hirano K; Tanaka M; Tada M; Fukayama M; Koike K
    Dig Dis Sci; 2014 Jul; 59(7):1578-85. PubMed ID: 24429514
    [TBL] [Abstract][Full Text] [Related]  

  • 33. EUS-guided 22-gauge fine-needle aspiration versus core biopsy needle in the evaluation of solid pancreatic neoplasms.
    Strand DS; Jeffus SK; Sauer BG; Wang AY; Stelow EB; Shami VM
    Diagn Cytopathol; 2014 Sep; 42(9):751-8. PubMed ID: 24550162
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles.
    Antonini F; Fuccio L; Giorgini S; Fabbri C; Frazzoni L; Scarpelli M; Macarri G
    Dig Liver Dis; 2017 Aug; 49(8):898-902. PubMed ID: 28465092
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Analysis of Fine-Needle Biopsy vs Fine-Needle Aspiration in Diagnosis of Pancreatic and Abdominal Masses: A Prospective, Multicenter, Randomized Controlled Trial.
    Cheng B; Zhang Y; Chen Q; Sun B; Deng Z; Shan H; Dou L; Wang J; Li Y; Yang X; Jiang T; Xu G; Wang G
    Clin Gastroenterol Hepatol; 2018 Aug; 16(8):1314-1321. PubMed ID: 28733257
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses.
    Vilmann P; Săftoiu A; Hollerbach S; Skov BG; Linnemann D; Popescu CF; Wellmann A; Gorunescu F; Clementsen P; Freund U; Flemming P; Hassan H; Gheonea DI; Streba L; Ioncică AM; Streba CT
    Scand J Gastroenterol; 2013 Jul; 48(7):877-83. PubMed ID: 23795663
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Accuracy and inter-observer agreement of the Procore™ 25 gauge needle for endoscopic ultrasound-guided tissue core biopsy.
    Attili F; Petrone G; Abdulkader I; Correale L; Inzani F; Iglesias-Garcia J; Hassan C; Andrade Zurita S; Rindi G; Dominguez-Muñoz JE; Costamagna G; Larghi A
    Dig Liver Dis; 2015 Nov; 47(11):943-9. PubMed ID: 26216067
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of the Diagnostic Performance of Newly Designed 21-Gauge and Standard 22-Gauge Aspiration Needles in Patients with Solid Pancreatic Masses.
    Minaga K; Yoshikawa T; Yamashita Y; Akamatsu H; Ikenouchi M; Ishii T; Matsumoto H; Iwagami H; Nakatani Y; Hatamaru K; Takenaka M; Akamatsu T; Uenoyama Y; Watanabe T; Ono K; Chiba Y; Kudo M
    Dig Dis Sci; 2019 Oct; 64(10):2982-2991. PubMed ID: 31011943
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of a 22-gauge Franseen-tip needle with a 20-gauge forward-bevel needle for the diagnosis of type 1 autoimmune pancreatitis: a prospective, randomized, controlled, multicenter study (COMPAS study).
    Kurita A; Yasukawa S; Zen Y; Yoshimura K; Ogura T; Ozawa E; Okabe Y; Asada M; Nebiki H; Shigekawa M; Ikeura T; Eguchi T; Maruyama H; Ueki T; Itonaga M; Hashimoto S; Shiomi H; Minami R; Hoki N; Takenaka M; Itokawa Y; Uza N; Hashigo S; Yasuda H; Takada R; Kamada H; Kawamoto H; Kawakami H; Moriyama I; Fujita K; Matsumoto H; Hanada K; Takemura T; Yazumi S
    Gastrointest Endosc; 2020 Feb; 91(2):373-381.e2. PubMed ID: 31654634
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Novel fork-tip needles versus standard needles for EUS-guided tissue acquisition from solid masses of the upper GI tract: a matched cohort study.
    Jovani M; Abidi WM; Lee LS
    Scand J Gastroenterol; 2017; 52(6-7):784-787. PubMed ID: 28355953
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 47.