These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 27637007)

  • 1. Reproducibility, interchangeability of measures, time to measure stabilization, and reference values of two tissue oximeters in healthy volunteers.
    Cournoyer A; Denault A; Cossette S; Fortier A; Daoust R; Iseppon M; Chauny JM; Notebaert E
    J Biomed Opt; 2016 Sep; 21(9):97003. PubMed ID: 27637007
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers.
    Bickler PE; Feiner JR; Rollins MD
    Anesth Analg; 2013 Oct; 117(4):813-823. PubMed ID: 24023027
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Association Between the Quantity of Subcutaneous Fat and the Inter-Device Agreement of 2 Tissue Oximeters.
    Cournoyer A; Cossette S; Paquet J; Daoust R; Marquis M; Notebaert É; Iseppon M; Chauny JM; Denault A
    J Cardiothorac Vasc Anesth; 2019 Nov; 33(11):2989-2994. PubMed ID: 30795969
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Peripheral tissue oximetry: comparing three commercial near-infrared spectroscopy oximeters on the forearm.
    Hyttel-Sorensen S; Hessel TW; Greisen G
    J Clin Monit Comput; 2014 Apr; 28(2):149-55. PubMed ID: 23990288
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dynamic evaluation of near-infrared peripheral oximetry in healthy volunteers: a comparison between INVOS and EQUANOX.
    Fellahi JL; Butin G; Fischer MO; Zamparini G; Gérard JL; Hanouz JL
    J Crit Care; 2013 Oct; 28(5):881.e1-6. PubMed ID: 23768447
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of critical cerebral desaturation thresholds by three regional oximeters during hypoxia: a pilot study in healthy volunteers.
    Tomlin KL; Neitenbach AM; Borg U
    BMC Anesthesiol; 2017 Jan; 17(1):6. PubMed ID: 28086807
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cerebral oxygenation after birth - a comparison of INVOS(®) and FORE-SIGHT™ near-infrared spectroscopy oximeters.
    Hessel TW; Hyttel-Sorensen S; Greisen G
    Acta Paediatr; 2014 May; 103(5):488-93. PubMed ID: 24456266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct comparison between cerebral oximetry by INVOS(TM) and EQUANOX(TM) during cardiac surgery: a pilot study.
    Pisano A; Galdieri N; Iovino TP; Angelone M; Corcione A
    Heart Lung Vessel; 2014; 6(3):197-203. PubMed ID: 25279362
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies.
    Davie SN; Grocott HP
    Anesthesiology; 2012 Apr; 116(4):834-40. PubMed ID: 22343469
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Four-wavelength near-infrared peripheral oximetry in cardiac surgery patients: a comparison between EQUANOX and O3.
    Ferraris A; Jacquet-Lagrèze M; Fellahi JL
    J Clin Monit Comput; 2018 Apr; 32(2):253-259. PubMed ID: 28466202
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Extracranial contamination in the INVOS 5100C versus the FORE-SIGHT ELITE cerebral oximeter: a prospective observational crossover study in volunteers.
    Greenberg S; Murphy G; Shear T; Patel A; Simpson A; Szokol J; Avram MJ; Vender J
    Can J Anaesth; 2016 Jan; 63(1):24-30. PubMed ID: 26307186
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcranial optical spectroscopy--A comparison of the TOS 96 and INVOS 3100 cerebral oximeters.
    Litscher G; Hadolt I; Eger E
    Biomed Tech (Berl); 1998 May; 43(5):133-6. PubMed ID: 9616992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Different Near-Infrared Spectroscopy Devices for Assessing Tissue Oxygenation with a Vascular Occlusion Test in Healthy Volunteers.
    Chung J; Ji SH; Jang YE; Kim EH; Lee JH; Kim JT; Kim HS
    J Vasc Res; 2020; 57(6):341-347. PubMed ID: 32894846
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effects of systemic oxygenation on cerebral oxygen saturation and its relationship to mixed venous oxygen saturation: A prospective observational study comparison of the INVOS and ForeSight Elite cerebral oximeters.
    Schmidt C; Heringlake M; Kellner P; Berggreen AE; Maurer H; Brandt S; Bucsky B; Petersen M; Charitos EI
    Can J Anaesth; 2018 Jul; 65(7):766-775. PubMed ID: 29484605
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements.
    Benni PB; MacLeod D; Ikeda K; Lin HM
    J Clin Monit Comput; 2018 Apr; 32(2):269-284. PubMed ID: 28374103
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of two devices using near-infrared spectroscopy for the measurement of tissue oxygenation during a vascular occlusion test in healthy volunteers (INVOS® vs. InSpectra™).
    Lee JH; Park YH; Kim HS; Kim JT
    J Clin Monit Comput; 2015 Apr; 29(2):271-8. PubMed ID: 25005912
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia.
    Gehring H; Hornberger C; Matz H; Konecny E; Schmucker P
    Respir Care; 2002 Jan; 47(1):48-60. PubMed ID: 11749687
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of posture and extracranial contamination on results of cerebral oximetry by near-infrared spectroscopy.
    Kato S; Yoshitani K; Kubota Y; Inatomi Y; Ohnishi Y
    J Anesth; 2017 Feb; 31(1):103-110. PubMed ID: 27807663
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of cerebral oxygenation state in anaesthetized children using the INVOS 5100 cerebral oximeter.
    Dullenkopf A; Frey B; Baenziger O; Gerber A; Weiss M
    Paediatr Anaesth; 2003 Jun; 13(5):384-91. PubMed ID: 12791110
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reproducibility of near-infrared spectroscopy parameters measured during brachial artery occlusion and reactive hyperemia in healthy men.
    Lacroix S; Gayda M; Gremeaux V; Juneau M; Tardif JC; Nigam A
    J Biomed Opt; 2012 Jul; 17(7):077010. PubMed ID: 22894522
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.