These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

319 related articles for article (PubMed ID: 27649345)

  • 1. Reemergence of Mycobacterium chimaera in Heater-Cooler Units despite Intensified Cleaning and Disinfection Protocol.
    Schreiber PW; Kuster SP; Hasse B; Bayard C; Rüegg C; Kohler P; Keller PM; Bloemberg GV; Maisano F; Bettex D; Halbe M; Sommerstein R; Sax H
    Emerg Infect Dis; 2016 Oct; 22(10):1830-3. PubMed ID: 27649345
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mycobacterium chimaera in heater-cooler units used during cardiac surgery - growth and decontamination.
    Bengtsson D; Westerberg M; Nielsen S; Ridell M; Jönsson B
    Infect Dis (Lond); 2018 Oct; 50(10):736-742. PubMed ID: 29688098
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Healthcare-Associated Mycobacterium chimaera Infection Subsequent to Heater-Cooler Device Exposure During Cardiac Surgery.
    Ninh A; Weiner M; Goldberg A
    J Cardiothorac Vasc Anesth; 2017 Oct; 31(5):1831-1835. PubMed ID: 28838729
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Genomic Analysis of Cardiac Surgery-Associated Mycobacterium chimaera Infections, United States.
    Hasan NA; Epperson LE; Lawsin A; Rodger RR; Perkins KM; Halpin AL; Perry KA; Moulton-Meissner H; Diekema DJ; Crist MB; Perz JF; Salfinger M; Daley CL; Strong M
    Emerg Infect Dis; 2019 Mar; 25(3):559-563. PubMed ID: 30789131
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Notes from the Field: Mycobacterium chimaera Contamination of Heater-Cooler Devices Used in Cardiac Surgery - United States.
    Perkins KM; Lawsin A; Hasan NA; Strong M; Halpin AL; Rodger RR; Moulton-Meissner H; Crist MB; Schwartz S; Marders J; Daley CL; Salfinger M; Perz JF
    MMWR Morb Mortal Wkly Rep; 2016 Oct; 65(40):1117-1118. PubMed ID: 27740609
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Different Types of Heater-Cooler Units and Their Risk of Transmission of Mycobacterium chimaera During Open-Heart Surgery: Clues From Device Design.
    Kuehl R; Banderet F; Egli A; Keller PM; Frei R; Döbele T; Eckstein F; Widmer AF
    Infect Control Hosp Epidemiol; 2018 Jul; 39(7):834-840. PubMed ID: 29804546
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mycobacterium chimaera in heater-cooler units: new technical approach for treatment, cleaning and disinfection protocol.
    Colangelo N; Giambuzzi I; Moro M; Pasqualini N; Aina A; De Simone F; Blasio A; Alfieri O; Castiglioni A; De Bonis M
    Perfusion; 2019 May; 34(4):272-276. PubMed ID: 30541392
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transmission of Mycobacterium chimaera from Heater-Cooler Units during Cardiac Surgery despite an Ultraclean Air Ventilation System.
    Sommerstein R; Rüegg C; Kohler P; Bloemberg G; Kuster SP; Sax H
    Emerg Infect Dis; 2016 Jun; 22(6):1008-13. PubMed ID: 27070958
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigating the Origin of Mycobacterium chimaera Contamination in Heater-Cooler Units: Integrated Analysis with Fourier Transform Infrared Spectroscopy and Whole-Genome Sequencing.
    Bisognin F; Messina F; Butera O; Nisii C; Mazzarelli A; Cristino S; Pascale MR; Lombardi G; Cannas A; Dal Monte P
    Microbiol Spectr; 2022 Dec; 10(6):e0289322. PubMed ID: 36222693
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mycobacterium chimaera infections following cardiac surgery in Italy: results from a National Survey Endorsed by the Italian Society of Cardiac Surgery.
    Cappabianca G; Paparella D; D'Onofrio A; Caprili L; Minniti G; Lanzafame M; Parolari A; Musumeci F; Beghi C
    J Cardiovasc Med (Hagerstown); 2018 Dec; 19(12):748-755. PubMed ID: 30300243
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical implications of Mycobacterium chimaera detection in thermoregulatory devices used for extracorporeal membrane oxygenation (ECMO), Germany, 2015 to 2016.
    Trudzinski FC; Schlotthauer U; Kamp A; Hennemann K; Muellenbach RM; Reischl U; Gärtner B; Wilkens H; Bals R; Herrmann M; Lepper PM; Becker SL
    Euro Surveill; 2016 Nov; 21(46):. PubMed ID: 27918254
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Response to Alert on Possible Infections with Mycobacterium chimaera From Contaminated Heater-Cooler Devices in Hospitals Participating in the Canadian Nosocomial Infection Surveillance Program (CNISP).
    Mertz D; Macri J; Hota S; Amaratunga K; Davis I; Johnston L; Lee B; Pelude L; Science M; Smith S; Wong A;
    Infect Control Hosp Epidemiol; 2018 Apr; 39(4):482-484. PubMed ID: 29488454
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Heater-cooler unit contamination with Mycobacterium chimaera - potential harmful risks for cardiac surgery patients.
    Jaworski R; Naumiuk Ł; Paczkowski K; Haponiuk I
    Kardiol Pol; 2017; 75(4):412-413. PubMed ID: 28421583
    [No Abstract]   [Full Text] [Related]  

  • 14.
    Quintás Viqueira A; Pérez Romero C; Toro Rueda C; Sánchez Calles AM; Blázquez González JA; Alejandre Leyva M
    New Microbes New Infect; 2021 Jan; 39():100757. PubMed ID: 33437492
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Disinfection and cleaning of heater-cooler units: suspension- and biofilm-killing.
    Falkinham JO
    J Hosp Infect; 2020 May; ():. PubMed ID: 32422308
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Genomic analysis of cardiac surgery-associated Mycobacterium chimaera infections in Italy.
    Ghodousi A; Borroni E; Peracchi M; Palù G; Fallico L; Rassu M; Manfrin V; Mantegani P; Monzillo V; Manganelli R; Tortoli E; Cirillo DM
    PLoS One; 2020; 15(9):e0239273. PubMed ID: 32976495
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microbiological monitoring of heater-cooler unit to keep free of Mycobacterium chimaera infection.
    Chan T; Ling ML; Teng SY; Chiu KY; James EM
    Perfusion; 2019 Jan; 34(1):9-14. PubMed ID: 29993322
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microbiological problems and biofilms associated with Mycobacterium chimaera in heater-cooler units used for cardiopulmonary bypass.
    Walker J; Moore G; Collins S; Parks S; Garvey MI; Lamagni T; Smith G; Dawkin L; Goldenberg S; Chand M
    J Hosp Infect; 2017 Jul; 96(3):209-220. PubMed ID: 28532976
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contamination during production of heater-cooler units by Mycobacterium chimaera potential cause for invasive cardiovascular infections: results of an outbreak investigation in Germany, April 2015 to February 2016.
    Haller S; Höller C; Jacobshagen A; Hamouda O; Abu Sin M; Monnet DL; Plachouras D; Eckmanns T
    Euro Surveill; 2016 Apr; 21(17):. PubMed ID: 27168588
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mycobacterium chimaera Infections Associated With Contaminated Heater-Cooler Devices for Cardiac Surgery: Outbreak Management.
    Marra AR; Diekema DJ; Edmond MB
    Clin Infect Dis; 2017 Aug; 65(4):669-674. PubMed ID: 28430899
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.