These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 27660042)

  • 1. A medical device-grade T1 and ECV phantom for global T1 mapping quality assurance-the T
    Captur G; Gatehouse P; Keenan KE; Heslinga FG; Bruehl R; Prothmann M; Graves MJ; Eames RJ; Torlasco C; Benedetti G; Donovan J; Ittermann B; Boubertakh R; Bathgate A; Royet C; Pang W; Nezafat R; Salerno M; Kellman P; Moon JC
    J Cardiovasc Magn Reson; 2016 Sep; 18(1):58. PubMed ID: 27660042
    [TBL] [Abstract][Full Text] [Related]  

  • 2. T
    Captur G; Bhandari A; Brühl R; Ittermann B; Keenan KE; Yang Y; Eames RJ; Benedetti G; Torlasco C; Ricketts L; Boubertakh R; Fatih N; Greenwood JP; Paulis LEM; Lawton CB; Bucciarelli-Ducci C; Lamb HJ; Steeds R; Leung SW; Berry C; Valentin S; Flett A; de Lange C; DeCobelli F; Viallon M; Croisille P; Higgins DM; Greiser A; Pang W; Hamilton-Craig C; Strugnell WE; Dresselaers T; Barison A; Dawson D; Taylor AJ; Mongeon FP; Plein S; Messroghli D; Al-Mallah M; Grieve SM; Lombardi M; Jang J; Salerno M; Chaturvedi N; Kellman P; Bluemke DA; Nezafat R; Gatehouse P; Moon JC;
    J Cardiovasc Magn Reson; 2020 May; 22(1):31. PubMed ID: 32375896
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Developing a medical device-grade T
    Topriceanu CC; Fornasiero M; Seo H; Webber M; Keenan KE; Stupic KF; Bruehl R; Ittermann B; Price K; McGrath L; Pang W; Hughes AD; Nezafat R; Kellman P; Pierce I; Moon JC; Captur G
    J Cardiovasc Magn Reson; 2023 Mar; 25(1):19. PubMed ID: 36935515
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magnetic resonance imaging phantoms for quality-control of myocardial T1 and ECV mapping: specific formulation, long-term stability and variation with heart rate and temperature.
    Vassiliou VS; Heng EL; Gatehouse PD; Donovan J; Raphael CE; Giri S; Babu-Narayan SV; Gatzoulis MA; Pennell DJ; Prasad SK; Firmin DN
    J Cardiovasc Magn Reson; 2016 Sep; 18(1):62. PubMed ID: 27659737
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reference ranges of myocardial T1 and T2 mapping in healthy Chinese adults: a multicenter 3T cardiovascular magnetic resonance study.
    Xu Z; Li W; Wang J; Wang F; Sun B; Xiang S; Luo X; Meng Y; Wang X; Wang X; Song J; Zhang M; Xu D; Zhou X; Ju Z; Sun J; Han Y; Chen Y
    J Cardiovasc Magn Reson; 2023 Nov; 25(1):64. PubMed ID: 37968645
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quality assurance of quantitative cardiac T1-mapping in multicenter clinical trials - A T1 phantom program from the hypertrophic cardiomyopathy registry (HCMR) study.
    Zhang Q; Werys K; Popescu IA; Biasiolli L; Ntusi NAB; Desai M; Zimmerman SL; Shah DJ; Autry K; Kim B; Kim HW; Jenista ER; Huber S; White JA; McCann GP; Mohiddin SA; Boubertakh R; Chiribiri A; Newby D; Prasad S; Radjenovic A; Dawson D; Schulz-Menger J; Mahrholdt H; Carbone I; Rimoldi O; Colagrande S; Calistri L; Michels M; Hofman MBM; Anderson L; Broberg C; Andrew F; Sanz J; Bucciarelli-Ducci C; Chow K; Higgins D; Broadbent DA; Semple S; Hafyane T; Wormleighton J; Salerno M; He T; Plein S; Kwong RY; Jerosch-Herold M; Kramer CM; Neubauer S; Ferreira VM; Piechnik SK
    Int J Cardiol; 2021 May; 330():251-258. PubMed ID: 33535074
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Phantom-based correction for standardization of myocardial native T1 and extracellular volume fraction in healthy subjects at 3-Tesla cardiac magnetic resonance imaging.
    Suh YJ; Kim PK; Park J; Park EA; Jung JI; Choi BW
    Eur Radiol; 2022 Dec; 32(12):8122-8130. PubMed ID: 35771246
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a temperature-controlled phantom for magnetic resonance quality assurance of diffusion, dynamic, and relaxometry measurements.
    Jerome NP; Papoutsaki MV; Orton MR; Parkes HG; Winfield JM; Boss MA; Leach MO; deSouza NM; Collins DJ
    Med Phys; 2016 Jun; 43(6):2998-3007. PubMed ID: 27277048
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A feasible and automatic free tool for T1 and ECV mapping.
    Altabella L; Borrazzo C; Carnì M; Galea N; Francone M; Fiorelli A; Di Castro E; Catalano C; Carbone I
    Phys Med; 2017 Jan; 33():47-55. PubMed ID: 28003137
    [TBL] [Abstract][Full Text] [Related]  

  • 10. T1, T2, and Fat Fraction Cardiac MR Fingerprinting: Preliminary Clinical Evaluation.
    Jaubert O; Cruz G; Bustin A; Hajhosseiny R; Nazir S; Schneider T; Koken P; Doneva M; Rueckert D; Masci PG; Botnar RM; Prieto C
    J Magn Reson Imaging; 2021 Apr; 53(4):1253-1265. PubMed ID: 33124081
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study.
    Dabir D; Child N; Kalra A; Rogers T; Gebker R; Jabbour A; Plein S; Yu CY; Otton J; Kidambi A; McDiarmid A; Broadbent D; Higgins DM; Schnackenburg B; Foote L; Cummins C; Nagel E; Puntmann VO
    J Cardiovasc Magn Reson; 2014 Oct; 16(1):69. PubMed ID: 25384607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement reproducibility of slice-interleaved T1 and T2 mapping sequences over 20 months: A single center study.
    Jang J; Ngo LH; Captur G; Moon JC; Nezafat R
    PLoS One; 2019; 14(7):e0220190. PubMed ID: 31344078
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myocardial T
    Weingärtner S; Meßner NM; Budjan J; Loßnitzer D; Mattler U; Papavassiliu T; Zöllner FG; Schad LR
    J Cardiovasc Magn Reson; 2016 Nov; 18(1):84. PubMed ID: 27855705
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative imaging metrics derived from magnetic resonance fingerprinting using ISMRM/NIST MRI system phantom: An international multicenter repeatability and reproducibility study.
    Shridhar Konar A; Qian E; Geethanath S; Buonincontri G; Obuchowski NA; Fung M; Gomez P; Schulte R; Cencini M; Tosetti M; Schwartz LH; Shukla-Dave A
    Med Phys; 2021 May; 48(5):2438-2447. PubMed ID: 33690905
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A liver-mimicking MRI phantom for thermal ablation experiments.
    Bazrafshan B; Hübner F; Farshid P; Larson MC; Vogel V; Mäntele W; Vogl TJ
    Med Phys; 2011 May; 38(5):2674-84. PubMed ID: 21776804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Free-breathing, non-ECG, continuous myocardial T
    Shaw JL; Yang Q; Zhou Z; Deng Z; Nguyen C; Li D; Christodoulou AG
    Magn Reson Med; 2019 Apr; 81(4):2450-2463. PubMed ID: 30450749
    [TBL] [Abstract][Full Text] [Related]  

  • 17. T
    Maforo NG; Magrath P; Moulin K; Shao J; Kim GH; Prosper A; Renella P; Wu HH; Halnon N; Ennis DB
    J Cardiovasc Magn Reson; 2020 Dec; 22(1):85. PubMed ID: 33302967
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Myocardial First-Pass Perfusion With Increased Anatomic Coverage at 3 T Using Autocalibrated Multiband Imaging.
    Zou L; Zheng Y; Chen J; Ding Y; Liu H; Liu Y; Xu J; Zheng H; Liu X
    J Magn Reson Imaging; 2023 Jan; 57(1):178-188. PubMed ID: 35426192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Age and sex corrected normal reference values of T1, T2 T2* and ECV in healthy subjects at 3T CMR.
    Roy C; Slimani A; de Meester C; Amzulescu M; Pasquet A; Vancraeynest D; Vanoverschelde JL; Pouleur AC; Gerber BL
    J Cardiovasc Magn Reson; 2017 Sep; 19(1):72. PubMed ID: 28934962
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multiparametric cardiovascular magnetic resonance characteristics and dynamic changes in myocardial and skeletal muscles in idiopathic inflammatory cardiomyopathy.
    Xu Y; Sun J; Wan K; Yu L; Wang J; Li W; Yang F; Sun J; Cheng W; Mui D; Zhang Q; Xie Q; Chen Y
    J Cardiovasc Magn Reson; 2020 Apr; 22(1):22. PubMed ID: 32272936
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.