These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 27662560)

  • 1. Cerebral Oximetry During CEA: Is It an Ideal Monitor?
    Waje ND; Maddali MM; Chatterjee N
    J Neurosurg Anesthesiol; 2017 Oct; 29(4):465-466. PubMed ID: 27662560
    [No Abstract]   [Full Text] [Related]  

  • 2. The role of cerebral oximetry in combination with awake testing in patients undergoing carotid endarterectomy under local anaesthesia.
    Ritter JC; Green D; Slim H; Tiwari A; Brown J; Rashid H
    Eur J Vasc Endovasc Surg; 2011 May; 41(5):599-605. PubMed ID: 21354833
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comments regarding 'the role of cerebral oximetry in combination with awake testing in patients undergoing carotid endarterectomy under local anaesthesia'.
    Gough MJ
    Eur J Vasc Endovasc Surg; 2011 May; 41(5):606. PubMed ID: 21388836
    [No Abstract]   [Full Text] [Related]  

  • 4. Is NIRS-based Cerebral Oximetry Sufficient Monitoring Modality During ICG Utilization in CEA?
    Manohar N; Reddy KR; Chakrabarti D
    J Neurosurg Anesthesiol; 2016 Jan; 28(1):87-8. PubMed ID: 26274625
    [No Abstract]   [Full Text] [Related]  

  • 5. The sensibility and specificity of cerebral oximetry, measured by INVOS - 4100, in patients undergoing carotid endarterectomy compared with awake testing.
    Stilo F; Spinelli F; Martelli E; Pipitó N; Barillà D; De Caridi G; Benedetto F; Risitano D; Noto A; Messina R; David A
    Minerva Anestesiol; 2012 Oct; 78(10):1126-35. PubMed ID: 23059517
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of near-infrared cerebral oximetry in awake carotid endarterectomy.
    Carlin RE; McGraw DJ; Calimlim JR; Mascia MF
    J Clin Anesth; 1998 Mar; 10(2):109-13. PubMed ID: 9524894
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Significant correlation between cerebral oximetry and carotid stump pressure during carotid endarterectomy.
    Lee TS; Hines GL; Feuerman M
    Ann Vasc Surg; 2008 Jan; 22(1):58-62. PubMed ID: 18023554
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Assessment of brain protection by means of cerebral oximetry incarotid endarterectomy].
    Karpenko AA; Levicheva EN; Starodubtsev VB; Loginova IIu; Kamenskaia OV; Cherniavskiĭ AM
    Angiol Sosud Khir; 2010; 17(1):113-7. PubMed ID: 21780628
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lactate flux during carotid endarterectomy under general anesthesia: correlation with various point-of-care monitors.
    Espenell AE; McIntyre IW; Gulati H; Girling LG; Wilkinson MF; Silvaggio JA; Koulack J; West M; Harding GE; Kaufmann AM; Mutch WA
    Can J Anaesth; 2010 Oct; 57(10):903-12. PubMed ID: 20661680
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cerebral monitoring in patients undergoing carotid endarterectomy using a triple assessment technique.
    Ali AM; Green D; Zayed H; Halawa M; El-Sakka K; Rashid HI
    Interact Cardiovasc Thorac Surg; 2011 Mar; 12(3):454-7. PubMed ID: 21098425
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cerebral oxygenation and processed EEG response to clamping and shunting during carotid endarterectomy under general anesthesia.
    Perez W; Dukatz C; El-Dalati S; Duncan J; Abdel-Rasoul M; Springer A; Go MR; Dzwonczyk R
    J Clin Monit Comput; 2015 Dec; 29(6):713-20. PubMed ID: 25572653
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of carotid revascularization on cerebral autoregulation in combined cardiac surgery†.
    Hori D; Ono M; Adachi H; Hogue CW
    Eur J Cardiothorac Surg; 2016 Jan; 49(1):281-7. PubMed ID: 25646403
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review.
    Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ
    Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cerebral oximetry: a useful monitor during carotid artery surgery.
    Fearn SJ; Mead GE; Picton AJ; Mortimer AJ; McCollum CN
    Anaesthesia; 1996 Jun; 51(6):610-1. PubMed ID: 8694241
    [No Abstract]   [Full Text] [Related]  

  • 15. Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia.
    Fearn SJ; Mead GE; Picton AJ; McCollum CN; Mortimer AJ
    Stroke; 1996 Aug; 27(8):1436-7. PubMed ID: 8711817
    [No Abstract]   [Full Text] [Related]  

  • 16. Cerebral oximetry: monitoring the brain as the index organ.
    Murkin JM
    Anesthesiology; 2011 Jan; 114(1):12-3. PubMed ID: 21178667
    [No Abstract]   [Full Text] [Related]  

  • 17. Does standardised post-CEA blood pressure control make cerebral monitoring for hyperperfusion irrelevant?
    de Borst GJ; Moll FL
    Eur J Vasc Endovasc Surg; 2013 Jun; 45(6):572. PubMed ID: 23602855
    [No Abstract]   [Full Text] [Related]  

  • 18. Practical use of near-infrared spectroscopy in carotid surgery.
    Radak D; Sotirovic V; Obradovic M; Isenovic ER
    Angiology; 2014 Oct; 65(9):769-72. PubMed ID: 24176911
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Cerebral oximetry in pulmonary thromboendarterectomy with circulatory arrest].
    Catalán Escudero P; González Román A; Serra Ruiz CN; Barbero Mielgo M; García Fernández J
    Rev Esp Anestesiol Reanim; 2014 Feb; 61(2):101-4. PubMed ID: 23266343
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy.
    Rigamonti A; Scandroglio M; Minicucci F; Magrin S; Carozzo A; Casati A
    J Clin Anesth; 2005 Sep; 17(6):426-30. PubMed ID: 16171662
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.