21. Comparison of stainless steel and composite plates in the healing of diaphyseal osteotomies of the dog radius: report on a short term study. Coutts RE; Akeson WH; Woo S; Matthews JV; Gonsalves M; Amiel D Orthop Clin North Am; 1976 Jan; 7(1):223-9. PubMed ID: 1256790 [TBL] [Abstract][Full Text] [Related]
22. [Influence of stress-relaxation plate on bone geometrics and mechanical property: an experimental study]. Dai K; Dai M; Wang K Zhonghua Yi Xue Za Zhi; 1995 Jul; 75(7):414-6, 446. PubMed ID: 7553161 [TBL] [Abstract][Full Text] [Related]
23. [Experimental studies of the effects of prestress on intact canine bone structure]. Liu B; Lu S; Wang J Zhonghua Wai Ke Za Zhi; 1995 Jun; 33(6):374-7. PubMed ID: 8582227 [TBL] [Abstract][Full Text] [Related]
24. Locking plates increase the strength of dynamic hip screws. Jewell DP; Gheduzzi S; Mitchell MS; Miles AW Injury; 2008 Feb; 39(2):209-12. PubMed ID: 17880976 [TBL] [Abstract][Full Text] [Related]
25. [Stress analysis following femoral shaft osteotomy fixed using various plates with different rigidities in a simulation test]. Xu X Zhonghua Yi Xue Za Zhi; 1990 Apr; 70(4):186-90, 14. PubMed ID: 2167754 [TBL] [Abstract][Full Text] [Related]
26. Stresses in plated long-bones: the role of screw tightness and interface slipping. Beaupré GS; Carter DR; Orr TE; Csongradi J J Orthop Res; 1988; 6(1):39-50. PubMed ID: 3334738 [TBL] [Abstract][Full Text] [Related]
27. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate. Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L Clin Biomech (Bristol); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766 [TBL] [Abstract][Full Text] [Related]
30. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model. Cullen AB; Curtiss S; Lee MA J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460 [TBL] [Abstract][Full Text] [Related]
31. A short plate compression screw with diagonal bolts--a biomechanical evaluation performed experimentally and by numerical computation. Peleg E; Mosheiff R; Liebergall M; Mattan Y Clin Biomech (Bristol); 2006 Nov; 21(9):963-8. PubMed ID: 16893595 [TBL] [Abstract][Full Text] [Related]
32. Comminuted talar neck fractures: a mechanical comparison of fixation techniques. Attiah M; Sanders DW; Valdivia G; Cooper I; Ferreira L; MacLeod MD; Johnson JA J Orthop Trauma; 2007 Jan; 21(1):47-51. PubMed ID: 17211269 [TBL] [Abstract][Full Text] [Related]
33. A comparative biomechanical evaluation of mandibular condyle fracture plating techniques. Asprino L; Consani S; de Moraes M J Oral Maxillofac Surg; 2006 Mar; 64(3):452-6. PubMed ID: 16487808 [TBL] [Abstract][Full Text] [Related]
34. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. Tejwani NC; Murthy A; Park J; McLaurin TM; Egol KA; Kummer FJ J Trauma; 2009 Mar; 66(3):795-9. PubMed ID: 19276755 [TBL] [Abstract][Full Text] [Related]
35. Assessment of carbon fibre composite fracture fixation plate using finite element analysis. Saidpour SH Ann Biomed Eng; 2006 Jul; 34(7):1157-63. PubMed ID: 16732432 [TBL] [Abstract][Full Text] [Related]
36. Locked vs. unlocked plate osteosynthesis of the proximal humerus - a biomechanical study. Seide K; Triebe J; Faschingbauer M; Schulz AP; Püschel K; Mehrtens G; Jürgens Ch Clin Biomech (Bristol); 2007 Feb; 22(2):176-82. PubMed ID: 17134800 [TBL] [Abstract][Full Text] [Related]
37. Supracondylar femur fracture fixation: mechanical comparison of the 95 degrees condylar side plate and screw versus 95 degrees angled blade plate. Jaakkola JI; Lundy DW; Moore T; Jones B; Ganey TM; Hutton WC Acta Orthop Scand; 2002 Jan; 73(1):72-6. PubMed ID: 11928916 [TBL] [Abstract][Full Text] [Related]
38. Mechanical effects of high density polyethylene dynamic compression plate hole inserts on bone-plate constructs. Sullivan EK; Nunamaker DM; Richardson DW Vet Comp Orthop Traumatol; 2005; 18(2):63-6. PubMed ID: 16594199 [TBL] [Abstract][Full Text] [Related]
39. Rigid or sliding plate. A mechanical evaluation of osteotomy fixation in sheep. Panagiotopoulos E; Fortis AP; Lambiris E; Kostopoulos V Clin Orthop Relat Res; 1999 Jan; (358):244-9. PubMed ID: 9973997 [TBL] [Abstract][Full Text] [Related]
40. Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures. Boswell S; McIff TE; Trease CA; Toby EB J Hand Surg Am; 2007; 32(5):623-9. PubMed ID: 17481999 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]