183 related articles for article (PubMed ID: 27669257)
1. Characterization of Biosensors Based on Recombinant Glutamate Oxidase: Comparison of Crosslinking Agents in Terms of Enzyme Loading and Efficiency Parameters.
Ford R; Quinn SJ; O'Neill RD
Sensors (Basel); 2016 Sep; 16(10):. PubMed ID: 27669257
[TBL] [Abstract][Full Text] [Related]
2. Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate.
McMahon CP; Rocchitta G; Serra PA; Kirwan SM; Lowry JP; O'Neill RD
Anal Chem; 2006 Apr; 78(7):2352-9. PubMed ID: 16579619
[TBL] [Abstract][Full Text] [Related]
3. A robust, state-of-the-art amperometric microbiosensor for glutamate detection.
Sirca D; Vardeu A; Pinna M; Diana M; Enrico P
Biosens Bioelectron; 2014 Nov; 61():526-31. PubMed ID: 24951923
[TBL] [Abstract][Full Text] [Related]
4. Oxygen tolerance of an implantable polymer/enzyme composite glutamate biosensor displaying polycation-enhanced substrate sensitivity.
McMahon CP; Rocchitta G; Kirwan SM; Killoran SJ; Serra PA; Lowry JP; O'Neill RD
Biosens Bioelectron; 2007 Feb; 22(7):1466-73. PubMed ID: 16887344
[TBL] [Abstract][Full Text] [Related]
5. The efficiency of immobilised glutamate oxidase decreases with surface enzyme loading: an electrostatic effect, and reversal by a polycation significantly enhances biosensor sensitivity.
McMahon CP; Rocchitta G; Serra PA; Kirwan SM; Lowry JP; O'Neill RD
Analyst; 2006 Jan; 131(1):68-72. PubMed ID: 16365665
[TBL] [Abstract][Full Text] [Related]
6. Accurate glutamate monitoring in foodstuffs by a sensitive and interference-free glutamate oxidase based disposable amperometric biosensor.
Mentana A; Nardiello D; Palermo C; Centonze D
Anal Chim Acta; 2020 Jun; 1115():16-22. PubMed ID: 32370865
[TBL] [Abstract][Full Text] [Related]
7. Carbon nanohorn modified platinum electrodes for improved immobilisation of enzyme in the design of glutamate biosensors.
Ford R; Devereux SJ; Quinn SJ; O'Neill RD
Analyst; 2019 Aug; 144(17):5299-5307. PubMed ID: 31373591
[TBL] [Abstract][Full Text] [Related]
8. Development of a novel micro biosensor for in vivo monitoring of glutamate release in the brain.
Ganesana M; Trikantzopoulos E; Maniar Y; Lee ST; Venton BJ
Biosens Bioelectron; 2019 Apr; 130():103-109. PubMed ID: 30731343
[TBL] [Abstract][Full Text] [Related]
9. An amperometric biosensor for L-glutamate determination prepared from L-glutamate oxidase immobilized in polypyrrole-polyvinylsulphonate film.
Şimşek Ş; Aynacı E; Arslan F
Artif Cells Nanomed Biotechnol; 2016; 44(1):356-61. PubMed ID: 25682838
[TBL] [Abstract][Full Text] [Related]
10. Immobilization method to preserve enzyme specificity in biosensors: consequences for brain glutamate detection.
Vasylieva N; Maucler C; Meiller A; Viscogliosi H; Lieutaud T; Barbier D; Marinesco S
Anal Chem; 2013 Feb; 85(4):2507-15. PubMed ID: 23358125
[TBL] [Abstract][Full Text] [Related]
11. Enzyme immobilization strategies and electropolymerization conditions to control sensitivity and selectivity parameters of a polymer-enzyme composite glucose biosensor.
Rothwell SA; Killoran SJ; O'Neill RD
Sensors (Basel); 2010; 10(7):6439-62. PubMed ID: 22163559
[TBL] [Abstract][Full Text] [Related]
12. Covalent enzyme immobilization by poly(ethylene glycol) diglycidyl ether (PEGDE) for microelectrode biosensor preparation.
Vasylieva N; Barnych B; Meiller A; Maucler C; Pollegioni L; Lin JS; Barbier D; Marinesco S
Biosens Bioelectron; 2011 Jun; 26(10):3993-4000. PubMed ID: 21546239
[TBL] [Abstract][Full Text] [Related]
13. A novel approach for the selective analysis of l-lysine in untreated human serum by a co-crosslinked l-lysine-α-oxidase/overoxidized polypyrrole bilayer based amperometric biosensor.
Ciriello R; De Gennaro F; Frascaro S; Guerrieri A
Bioelectrochemistry; 2018 Dec; 124():47-56. PubMed ID: 30007206
[TBL] [Abstract][Full Text] [Related]
14. Biosensor for neurotransmitter L-glutamic acid designed for efficient use of L-glutamate oxidase and effective rejection of interference.
Ryan MR; Lowry JP; O'Neill RD
Analyst; 1997 Nov; 122(11):1419-24. PubMed ID: 9474818
[TBL] [Abstract][Full Text] [Related]
15. Development of biosensor based on immobilized L-glutamate oxidase for determination of monosodium glutamate in food.
Basu AK; Chattopadhyay P; Roychudhuri U; Chakraborty R
Indian J Exp Biol; 2006 May; 44(5):392-8. PubMed ID: 16708893
[TBL] [Abstract][Full Text] [Related]
16. Receptors and enzymes for medical sensing of L-glutamate.
Hirano A; Sugawara M
Mini Rev Med Chem; 2006 Oct; 6(10):1091-100. PubMed ID: 17073709
[TBL] [Abstract][Full Text] [Related]
17. A Detailed Model of Electroenzymatic Glutamate Biosensors To Aid in Sensor Optimization and in Applications in Vivo.
Clay M; Monbouquette HG
ACS Chem Neurosci; 2018 Feb; 9(2):241-251. PubMed ID: 29076724
[TBL] [Abstract][Full Text] [Related]
18. An amperometric hemoglobin A1c biosensor based on immobilization of fructosyl amino acid oxidase onto zinc oxide nanoparticles-polypyrrole film.
Chawla S; Pundir CS
Anal Biochem; 2012 Nov; 430(2):156-62. PubMed ID: 22906687
[TBL] [Abstract][Full Text] [Related]
19. An amperometric glutamate biosensor based on immobilization of glutamate oxidase onto carboxylated multiwalled carbon nanotubes/gold nanoparticles/chitosan composite film modified Au electrode.
Batra B; Pundir CS
Biosens Bioelectron; 2013 Sep; 47():496-501. PubMed ID: 23628843
[TBL] [Abstract][Full Text] [Related]
20. Construction of a potentiometric glutamate biosensor for determination of glutamate in some real samples.
Y Lmaz D; Karaku E
Artif Cells Blood Substit Immobil Biotechnol; 2011 Dec; 39(6):385-91. PubMed ID: 22066795
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]